• Title/Summary/Keyword: Collapsibility

Search Result 24, Processing Time 0.026 seconds

Collapsibility Using Raindrop Plot (RAINDROP PLOT을 이용한 차원축소)

  • Hong C. S.;Kim B. J.;Park J. Y.
    • The Korean Journal of Applied Statistics
    • /
    • v.18 no.2
    • /
    • pp.471-485
    • /
    • 2005
  • For categorical data analysis, the collapsibility were explained with the odds ratio (cross-product ratio). When these theories with these odds ratios are applied to real $2{\times}2{\times}K$ contingency tables, it is impossible to decide whether data are collapsible. Among graphical methods to represent odds ratios, Contour plot which is developed by Doi, Nakamura and Yamamoto (2001) could explain the structure of these data, but cannot decide on the collapsibility. In this paper, by using the Raindrop plot proposed by Barrowman and Myers (2003), we suggest an alternative method which can not only explain the structure of data, but also decide on the collapsibility.

Effect of Mandibular Repositioning Device on Airway Size and Airway Collapsibility in Obstructive Sleep Apnea Syndrome : Cine CT during Sleep (수면무호흡증 환자에서 Mandibular Repositioning Device가 Airway size와 Airway Collapsibility에 미치는 효과)

  • Hong, Seung-Bong;Kyung, Seung-Hyun;Han, Hyun-Jung;Na, Dong-Kyu;Son, Young-Ik;Park, Young-Chel
    • Sleep Medicine and Psychophysiology
    • /
    • v.6 no.2
    • /
    • pp.110-115
    • /
    • 1999
  • Objectives: To investigate the effect of mandibular repasitioning device on airway sige and airway collapsibility in patients with obstructive sleep apnea syndrome(OSAS). Methods: Cine CT with polysomnographic monitoring was performed during sleep in nine(OSAS) patients before and after manibular repositioning device(MRD) application. Axial CT images were obtained in five upper airway levels(retropalatal-high, retroalatal-low, retroglossal, epiglottis, and hypopharynx levels). In each airway level, one axial CT image was obtained during sleep apnea period and 10 serial axial CT images were scanned every 1 second during normal sleep breathing. After wearing MRD, all CT images were obtained by the same method. The cross-sectional areas of airway were measured by automatic tracing method. The changes of minimum airway size and maximum airway size after MRD were evaluated. The airway collapsibility was calculaed before and after MRD. Results: During sleep apnea, the airway of retropalatal-low level was the most frequently narrowest site. During normal sleep breahing the minimum airway size was increased significantly after MRD at retropalatal-low level(p=0.011). The mean airway collapsibility was the highest at retropalatal-low level. MRD decreased the airway collapsibility significantly at retropalatal-low level(p=0.021) and epiglottis level(p=0.038). Conclusions: The enlargement of the minimum airway size and decreased airway collapsibility may be the therapeutic mechanism of MRD in obstructive sleep apnea.

  • PDF

Effect of L.D Converter Slag Hardener on the Collapsibility of Sand Molds Using Sodium Silicate Binder (규산소오다계 자경성주형의 붕괴성에 미치는 L.D 전로 슬래그 경화제의 영향)

  • Choi, Jun-Oh;Park, Sung-Taik;Han, Yun-Sung;Choi, Chang-Ock
    • Journal of Korea Foundry Society
    • /
    • v.23 no.5
    • /
    • pp.235-243
    • /
    • 2003
  • The collapsibility of sodium silicate-bonded sands mixed with the L.D converter slag powder to form a hardener were investigated. Five to six percent sodium silicate on the basis of silica sand and 30-40% L.D converter slag powder on the basis of sodium silicate, were mixed and the compressive strength, surface stability index(SSI), bench time, retained strength of the standard sand specimens were measured. The properties were similar to those of general inorganic bonded self-setting molds. The compressive strength and surface stability index were increased and the retained strength and bench time were decreased with increased amount of the L.D converter slag powder. The retained strength of sodium silicate-bonded self-setting molds with the L.D converter slag powder were decreased than $CO_2$ sand molds. The collapsibility of sodium silicate-bonded self-setting molds with the L.D converter slag powder were superior in comparison with $CO_2$ sand molds. The L.D converter slag powder could be used as hardener and collapse agent for the sodium silicate-bonded self-setting molds.

Collapsibility Criteria using Raindrop Plots

  • 홍종선;김범준
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2004.11a
    • /
    • pp.175-178
    • /
    • 2004
  • 범주형 자료분석에서 차원축소(collapsibility)는 오즈비로 설명되었다. 실제의 $2\times2\timesK$ 분할표 자료를 이 이론에 적용시켰을 때 오즈비의 값으로 차원축소가 가능한지의 여부를 판단하기는 어렵다. 오즈비를 시각적으로 표현하는 방법 중에서 Doi, Nakamura와 Yamamoto(2001)가 제안한 Contour plot을 통해서 분할표 자료를 설명하는 것은 가능하지만 차원축소의 가능성을 결정하기에는 한계가 있다. 본 연구에서는 오즈비의 신뢰구간을 시각적으로 표현할 수 있는 방법으로 Barrowman과 Myers(2003)가 제안한 Raindrop plot을 이용하여 $P_{\lambda,;,T}^M-policy$ 분할표 자료를 설명할 수 있으며 동시에 차원축소의 가능성을 판단할 수 있는 방법을 제안하고자 한다.

  • PDF

Suppression and Collapsibility for Log-linear Models

  • Sun, Hong-Chong
    • Communications for Statistical Applications and Methods
    • /
    • v.11 no.3
    • /
    • pp.519-527
    • /
    • 2004
  • Relationship between the partial likelihood ratio statistics for logisitic models and the partial goodness-of-fit statistics for corresponding log-linear models is discussed. This paper shows how definitions of suppression in logistic model can be adapted for log-linear model and how they are related to confounding in terms of collapsibility for categorical data. Several $2{times}2{times}2$ contingency tables are illustrated.

Effect of Retained Compression Strength on the Collapsibility of $CO_2$ Process (($CO_2$ 주형(鑄型)의 붕괴성(崩壞性)에 대한 잔류강도(殘留强度)의 변화(變化)에 관(關)한 연구(硏究))

  • Choi, Chang-Ock;Sung, Kyong-Hun
    • Journal of Korea Foundry Society
    • /
    • v.3 no.3
    • /
    • pp.181-187
    • /
    • 1983
  • Effects of retained compression strength on the collapsibility of $CO_2$ mold sand using sodium silicate were studied. The results obtained from the experiment are summurized as follows; 1) The sand mixtures increased their compression strength and retained compression strength when content of sodium silicate is high or mole ratio of sodium silicate is high. 2) Increase of retained strength has a maximum value at temperatures about $200^{\circ}C$. When the sample reached $800^{\circ}C$, the binder bridge are homogeneous. The retained strength is increased. 3) Decrease of retained strength at temperatures over $200^{\circ}C$ is caused by pore formation and additives of seacoal markedly accelerated pore formations.

  • PDF

Analysis of Large Tables (대규모 분할표 분석)

  • Choi, Hyun-Jip
    • The Korean Journal of Applied Statistics
    • /
    • v.18 no.2
    • /
    • pp.395-410
    • /
    • 2005
  • For the analysis of large tables formed by many categorical variables, we suggest a method to group the variables into several disjoint groups in which the variables are completely associated within the groups. We use a simple function of Kullback-Leibler divergence as a similarity measure to find the groups. Since the groups are complete hierarchical sets, we can identify the association structure of the large tables by the marginal log-linear models. Examples are introduced to illustrate the suggested method.

Contour Method and Collapsibility Criteria for $2{\times}3{\times}K$ Contingency Tables

  • Hong, C.S.;Son, B.U.;Park, J.Y.
    • Journal of the Korean Data and Information Science Society
    • /
    • v.15 no.4
    • /
    • pp.717-729
    • /
    • 2004
  • The contour method which was originally designed for $2{\times}2{\times}2$ contingency table is studied for $2{\times}2{\times}K$ and $2{\times}3{\times}K$ tables. Whereas a contour plot for a $2{\times}2{\times}K$ table is represented on unit squared two dimensional plane, a contour plot of a $2{\times}3{\times}K$ table can be expressed with a regular hexahedron on three dimensional space. Based on contour plots for categorical data fitted to all possible three dimensional log-linear models, one might identify whether $2{\times}2{\times}k$ or $2{\times}3{\times}K$ tables are collapsible over the third variable.

  • PDF

The Effect of Mandibular Protrusion on Dynamic Changes in Oropharyngeal Caliber (하악의 전방이동이 구인두 내경의 동적 변화에 미치는 영향)

  • Jung, Jae-Kwang;Hur, Yun-Kyung;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.3
    • /
    • pp.193-202
    • /
    • 2010
  • The purpose of this study was to determine the sites of narrowing/obstruction and to measure the regional severity of narrowing through the evaluation of dynamic changes in upper-airway of healthy subjects. The selected 9 subjects were proved not to have any sleep-related disorder such as snoring or obstructive sleep apnea through clinical examination, radiological examination, sleep study with a portable recording system. Afterward, the Electron Beam Tomography was performed during the waking and sleeping state of subjects, with their mandible in resting and protruded position. Intravenous injection of Dormicum$^{(R)}$ was used for the induction of sleep. The maximum and minimum cross-sectional areas at each airway level during tidal ventilation were measured and the Collapsibility Index for each level of cross-section was also computed. In a comparison with results under variable conditions, the result was showed that the significant difference between each airway level divided with upper, middle, lower region of upper airway is not observed in the average minimum cross-sectional areas and Collapsibility Index. The significant difference only between in wake and sleep state was observed in the average minimum cross-sectional area at the lower region. Also, in wake state, the significant difference between resting and protrusive position of mandible for the average minimum was also observed in cross-sectional area at middle region. In sleep state, no significant difference between resting and protrusive position of mandible was observed in cross-sectional area and the Collapsibility Index.