Variations of Column Shortening with Parameters (매개변수에 따른 기둥축소량 변화에 관한 연구)

  • 정은호;김형래
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.59-67
    • /
    • 2000
  • With increased height of structure, the effect of column shortening need special consideration in the design and construction of high-rise buildings. The shortening of each column affects nonstructural members such as partitions, cladding, and M/E systems, which are not designed to carry gravity forces. The slabs and beams will tilt due to the cumulative differential shortening of adeacent vertical members. The main purpose of estimating the total shortening of vertical structural member is to compensate the differential shortening between adeacent members. This paper presents effect of parameters for phenomenon of column shortening in vertical members. The paper presents effect of parameters for phenomenon of column shortening in vertical members. The conclusions obtained from this study are follow as ; Strength of concrete and steel ratio effected on column shortening caused by elastic and inelastic shortening. Also, it is known that Ultimate-shrinkage-Value, Specific-Creep-Value, and volume to surface ratio effected on inelastic shortening only. Particularly, Ultimate-Shrinkage-Value and Specific-Creep-Value effected considerable on the amount of total column shortening.

Evaluation of the influence of creep and shrinkage determinants on column shortening in mid-rise buildings

  • B-Jahromi, Ali;Rotimi, Abdulazeez;Tovi, Shivan;Goodchild, Charles;Rizzuto, Joseph
    • Advances in concrete construction
    • /
    • v.5 no.2
    • /
    • pp.155-171
    • /
    • 2017
  • The phenomenon of concrete column shortening has been widely acknowledged since it first became apparent in the 1960s. Axial column shortening is due to the combined effect of elastic and inelastic deformations, shrinkage and creep. This study aims to investigate the effects of ambient temperature, relative humidity, cement hardening speed and aggregate type on concrete column shortening. The investigation was conducted using a column shortening prediction model which is underpinned by the Eurocode 2. Critical analysis and evaluation of the results showed that the concrete aggregate types used in the concrete have significant impact on column shortening. Generally, aggregates with higher moduli of elasticity hold the best results in terms of shortening. Cement type used is another significant factor, as using slow hardening cement gives better results compared to rapid hardening cement. This study also showed that environmental factors, namely, ambient temperature and relative humidity have less impact on column shortening.

Field Measurement and Compensation Method of Column Shortening for SRC Columns in 37-story Residential Building (37층 초고층주상복합건물 SRC기둥의 기둥축소량 현장계측 및 보정법)

  • Song, Hwa-Cheol;Do,e Guen-Young;Cho, Hun-hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.4 s.18
    • /
    • pp.145-152
    • /
    • 2005
  • Long-term axial shortening of the vertical elements of tail buildings results in differential movements between two elements and may lead to the additional moments of connection beam and slab elements, and other secondary effects, such as cracks of partitions or curtain walls. Accurate prediction of time-dependent column shortening is essential for tall buildings from both strength and serviceability aspects. The compensation method is different from reinforced concrete and SRC(Steel Reinforced Concrete) members. The SRC columns are usually compensated according to total differential shortening between two vertical elements. In this study, column shortenings of 37-story W building under construction are predicted and compensated. The SRC column shortenings are compared with the actual column shortening by field measurement and the column shortenings are reanalysed and recompensated.

Column Shortening prediction and Field measurement of Tall building with Transfer floor (전이층을 가진 초고층건물의 기둥축소량 예측 및 현장계측)

  • Song Hwa-Cheol;Cho Yong-Soo;Chung Sung-Jin;Yoon Kwang-Sup;Lee Woo-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.175-181
    • /
    • 2006
  • The prediction of time-dependent column shortening is essential for tall buildings considering both strength and serviceability aspects. The Column shortening of tall buildings with transfer floor should be calculated considering the long-term deflection of transfer girder. In this study, both the column shortening and the deflection of transfer girder of 45-story tall concrete building are predicted. The column shortening considering deflection of transfer girder are compared with the actual column shortening by field measurement.

  • PDF

Prediction and Compensation of Differential Column Shortening in High-Rise Building Structures (고층건물 기둥의 부등축소량 예측 및 시공오차 보정에 관한 연구)

  • 조창휘;송진규;이현호;조석희
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1996.10a
    • /
    • pp.258-266
    • /
    • 1996
  • The purpose of this study is to make a reasonable correction in construction stage through exact prediction of long-time differential column shortening that occurs in the high-rise RC building. For this, a self-developed program adopted PCA code is used to predict differential column shortening with sequential loading process. Using this program, the amount of the different column shortening of Amatapura Apartment in Indonesia is predicted and the effect is analyzed. From the result, the major factor affecting the shortening amount in columns is elastic strain and the effect of shrinkage is very small rather than creep. And maximun differential column shortening is appeared near the middle of the building.

  • PDF

A study on the finish work of Reinforced Con'c slab for improving workability in the column shortening compensation. (기둥축소량 보정법에 있어서 시공성 향상을 위한 RC 슬래브 표면마무리에 관한 연구)

  • 소광호;이재옥;양극영
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.147-152
    • /
    • 2003
  • Passage of time axial shortening in the cores and columns of tall concrete buildings requires special attention to ensure proper behavior for strength of the structure and the nonstructural element. The effects of column shortening, both elastic and inelastic, take on added significance and need special consideration in design and construction with increased height of structures. In this paper, the compensation method of column shortening for reinforced concrete structure are introduced. It could be concluded that the survey is a significant factor for the compensation instance of column shortening.

  • PDF

Reduction of differential column shortening due to outrigger (아웃리거에 의한 부등기둥축소 감소효과)

  • Shin, Seung-Hak;Kim, Han-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.149-150
    • /
    • 2010
  • In this study, optimal location of outrigger for reduction of differential column shortening has been proposed. Optimal location of outrigger for reduction of differential column shortening is the position that the largest differential column shortening develops when the outrigger is not installed.

  • PDF

The Optimal Column Grouping Technique for the Compensation of Column Shortening (기둥축소량 보정을 위한 기둥의 최적그루핑기법)

  • Kim, Yeong-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.2
    • /
    • pp.141-148
    • /
    • 2011
  • This study presents the optimal grouping technique of columns which groups together columns of similar shortening trends to improve the efficiency of column shortening compensation. Here, Kohonen's self-organizing feature map which can classify patterns of input data by itself with unsupervised learning was used as the optimal grouping algorithm. The Kohonen network applied in this study is composed of two input neurons and variable output neurons, here the number of output neuron is equal to the column groups to be classified. In input neurons the normalized mean and standard deviation of shortening of each columns are inputted and in the output neurons the classified column groups are presented. The applicability of the proposed algorithm was evaluated by applying it to the two buildings where column shortening analyses had already been performed. The proposed algorithm was able to classify columns with similar shortening trends as one group, and from this we were able to ascertain the field-applicability of the proposed algorithm as the optimal grouping of column shortening.

Prediction, Field Measurement and Compensation of Column Shortening in Tall Building (초고층건물의 기둥축소량 예측, 계측 및 보정)

  • 조석희;김한수;김도균
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.143-146
    • /
    • 2003
  • Tall Buildings have been popular in recent years. Tall buildings require special consideration to design and construction due to their structural features. Column shortening is one of the important technologies to be considered in. The long-term deformations of concrete cause vertical shortening on cores and columns, trigger deformations on cladding, partitions and finishes, and damage their serviceability. This also affects structural stability by inducing unexpected stress to the structural members such as outrigger. The main objective of this paper is to re-evaluate column shortening according to revised field information and to compare the analysis results with the actual field measurement. Mok-Dong Hyperion, a 69-story apartment building which is currently under construction, was chosen for the case study.

  • PDF

Column Shortening Analysis and Field Measurement of Haeundae I'Park (초고층 건축물의 기둥축소량 해석 및 현장계측 - 해운대 아이파크)

  • Chung, Kwang-Ryang;Lee, Dae-Yong;Song, Ho-Beom;Park, Kwang-Min
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.67-70
    • /
    • 2011
  • The effect of column shortening is a major consideration in design and construction of tall buildings, especially in concrete and composite structural systems. To avoid unexpected demage in structural and nonstructural elements, differential shortening between vertical members resulting from differing stress levels, loading histories, volume-to-surface ratios and other factors in a high-rise building must be properly considered in the design process. This paper represents analyzed and measured shortening results of RC cores and columns at the 72 story Haeundae I'Park. It shows that WACS program based on ACI and PCA material model is effective for the prediction of column shortening.

  • PDF