• 제목/요약/키워드: Column Type

검색결과 1,203건 처리시간 0.023초

기둥 항복형 철골라멘의 복원력 특성 (Restoring Force Characteristics of Column Yield Type Steel Rahmen)

  • 윤명호
    • 한국디지털건축인테리어학회논문집
    • /
    • 제4권2호
    • /
    • pp.44-51
    • /
    • 2004
  • It is generally known in seismic design that the beam yield type frames have more advantages than column yield type of which damage is likely to concentrate to any story. However we may design a building as a beam yield type, it becomes actually a column yield type collapse mode for slab floor diaphragm effect. Considering these points, the column yield type frames are selected and designed as the specimens. The object of this study is to grasp quantitatively the restoring force characteristic values and to estimate the seismic performances of column yield type steel rahmen.

  • PDF

강관기둥과 PHC 파일을 연결하는 접합부에 관한 구조성능평가 (Structural Performance Evaluation of Joint between PHC Pile and Steel Tube Column)

  • 김상봉;오진탁;김영식;주영규
    • 한국공간구조학회논문집
    • /
    • 제15권3호
    • /
    • pp.85-93
    • /
    • 2015
  • This paper presents a foundation pile to steel column connection that can resist large magnitude of moment and that can be easy installed. The developed joint has spherical shape and it is given the name HAT joint to mean Hallow half-sphere steel joint. Four types of HAT joints are developed. Namely, H-type, T-type, P-type and K-type. In this paper I will talk about the performance assessment of T-type(Tube Column) and P-type(Pile Column) of HAT joints with finite element analysis and experiment on a full scale model is presented.

Virbration Characteristics of a passenger Car Steering Column

  • Lee, Young-Shin;Song, Sun-Young;Park, Myoung-Hwan;Ryu, Chung-Hyun;Kim, Young-Wann
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.130-141
    • /
    • 2000
  • The virbration characteristics of a passenger car steering column are studied by using a modal test and a finite element (FE) analysis. To verify the FE model and the results, an experiment using the impact exciting method is performed. Two types of the steering column in this study are considered as follows; (ⅰ) the non-tilt type steering column and (ⅱ) the upper-tilt type steering column. The experimental results are compared with those o the FE analysis, and it ti shown that the results agree with each other. The effects of various design parameters such as the bracket thickness, the column diameter on the natural frequencies are also investigated by FE analysis.

  • PDF

Seismic resistance of exterior beam-column joints with non-conventional confinement reinforcement detailing

  • Bindhu, K.R.;Jaya, K.P.;Manicka Selvam, V.K.
    • Structural Engineering and Mechanics
    • /
    • 제30권6호
    • /
    • pp.733-761
    • /
    • 2008
  • The failure of reinforced concrete structures in recent earthquakes caused concern about the performance of beam column joints. Confinement of joint is one of the ways to improve the performance of beam column joints during earthquakes. This paper describes an experimental study of exterior beam-column joints with two non-conventional reinforcement arrangements. One exterior beam-column joint of a six story building in seismic zone III of India was designed for earthquake loading. The transverse reinforcement of the joint assemblages were detailed as per IS 13920:1993 and IS 456:2000 respectively. The proposed nonconventional reinforcement was provided in the form of diagonal reinforcement on the faces of the joint, as a replacement of stirrups in the joint region for joints detailed as per IS 13920 and as additional reinforcement for joints detailed as per IS 456. These newly proposed detailing have the basic advantage of reducing the reinforcement congestion at the joint region. In order to study and compare the performance of joint with different detailing, four types of one-third scale specimens were cast (two numbers in each type). The main objective of the present study is to investigate the effectiveness of the proposed reinforcement detailing. All the specimens were tested under reverse cyclic loading, with appropriate axial load. From the test results, it was found that the beam-column joint having confining reinforcement as per IS: 456 with nonconventional detailing performed well. Test results indicate that the non-conventionally detailed specimens, Type 2 and Type 4 have an improvement in average ductility of 16% and 119% than their conventionally detailed counter parts (Type1 and Type 3). Further, the joint shear capacity of the Type 2 and Type 4 specimens are improved by 8.4% and 15.6% than the corresponding specimens of Type 1 and Type 3 respectively. The present study proposes a closed form expression to compute the yield and ultimate load of the system. This is accomplished using the theory of statics and the failure pattern observed during testing. Good correlation is found between the theoretical and experimental results.

컬럼-트리 형식 철골모멘트 접합부의 모델링 변수제안 (Modeling Parameters for Column-Tree Type Steel Beam-Column Connections)

  • 안희태;김태완;유은종
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.59-68
    • /
    • 2023
  • The column-tree type steel beam-column connections are commonly used in East Asian countries, including Korea. The welding detail between the stub beam and column is similar to the WUF-W connection; thus, it can be expected to have sufficient seismic performance. However, previous experimental studies indicate that premature slip occurs at the friction joints between the stub and link beams. In this study, for the accurate seismic performance evaluation of column-tree type moment connections, a moment-slip model was proposed by investigating the previous test results. As a result, it was found that the initial slip occurred at about 25% of the design slip moment strength, and the amount of slip was about 0.15%. Also, by comparing the analysis results from models with and without the slip element, the influence of slip on the performance of overall beam-column connections was examined. As the panel zone became weaker, the contribution of slip on overall deformation became greater, and the shear demand for the panel zone was reduced.

기둥 지지된 슬래브교의 모멘트 간략산정법에 관한 연구 (Bending Moment Analysis simpiified in Slab Bridges supported by Column Type Piers)

  • 이채규;김영인;김우
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.73-78
    • /
    • 1992
  • It would be much effective that single column type pier is used in concrete slab bridges rather than gravity type pier is used. To determine the longitudinal bonging moment in concrete slab bridges supported by single column type piers, the concept of effective width is applied. By elastic plate theory cooperated with finite element method, the distribution of the longitudinal moment of the slab supported by single column type piers is studied. The main variables are span, width, and thickness of the slab and column section size. Then the analytical results obtained are summarized and analysed to evaluate the maximum longitudinal negative moment by simple beam analysis.

  • PDF

DCM 타설 지반에 관한 실내모형실험 (Experimental Study on Soft Ground with DCM Column)

  • 홍기권
    • 한국지반신소재학회논문집
    • /
    • 제19권3호
    • /
    • pp.35-44
    • /
    • 2020
  • 본 연구에서는 연약지반에 설치된 DCM 개량체의 개량효과를 개량형식에 따라 정량적으로 비교하기 위하여 일련의 실내모형 실험을 수행하였다. 즉, 무보강 및 3종류의 DCM 개량체 형식에 대한 상재하중 재하에 따른 지반 거동을 재현하고, 지반의 침하량 및 측방변위량을 분석함으로써 DCM 개량형식에 따른 연약지반의 거동을 평가하였다. 먼저, 모형지반에 대한 성토하중 재하시험 결과 무보강의 경우에는 작은 하중 증가에도 침하가 급격히 발생한 반면에, DCM 개량체가 적용된 경우에는 상대적으로 적은 침하가 발생하였다. 그리고 상재하중 증가에 따른 지반의 측방유동 거동을 분석한 결과, 무보강의 경우에는 작은 하중 증가에도 불구하고 측방변위가 크게 발생되었다. 그러나 DCM 개량체가 적용된 경우에는 상대적으로 적은 측방유동이 발생되었으며, 동일한 하중조건에 대한 측방유동 발생량의 크기는 말뚝식, 벽식, 격자식의 순으로 나타남을 확인하였다. 따라서 격자식 DCM 개량체가 적용된 경우가 측방유동에 대하여 우수한 지반개량효과를 나타낸 것으로 평가되었다.

역원추형 발효조에서의 동시당화발효에 의한 전분으로 부터의 연속 에탄올 발효 (Continuous Ethanol Production from Starch by Simultaneous Saccharification and Fermentation in a Tapered Column Fermentor)

  • 김철호;유연우김철이상기
    • KSBB Journal
    • /
    • 제5권4호
    • /
    • pp.329-334
    • /
    • 1990
  • In an attempt to develop a novel process for ethanol production from starch, a simultaneous saccharification and fermentation (SSF) process using Zymomonas mobilis and amyloglucosidase (AMG) was studied in continuous modes. Compared with a conventional cylindrical column type of fermentor, the tapered column type of fermentor was found to be superior in terms of reactor performance for ethanol fermentation. The tapered columm fermentor packed with coimmobilized Z. mobilis and AMG alleviated the problems which were associated with CO2 evolution and provided a significantly better flow pattern for both liquid and gas phases in the fermentor without channelling. However, the fluidized bed type of tapered column fermentor using flocculent strain of Z. mobiles and immobilized AMG showed lower productivity (5.2g/1/h) than that of packed bed type of tapered column fermentor(9.2g/l/h).

  • PDF

On Beck's column with shear and compressibility

  • Cveticanin, L.J.;Atanackovic, T.M.
    • Structural Engineering and Mechanics
    • /
    • 제6권7호
    • /
    • pp.747-756
    • /
    • 1998
  • In this paper the influence of rotary inertia, shear and compressibility on the value of the critical force for the Beck's column is analyzed. The constitutive equation is of Engesser's type. As a result, the critical load parameter for which instability of flutter type occurs is calculated for several values of the column's parameters.

Static behavior of novel RCS through-column-type joint: Experimental and numerical study

  • Nguyen, Xuan Huy;Le, Dang Dung;Nguyen, Quang-Huy
    • Steel and Composite Structures
    • /
    • 제32권1호
    • /
    • pp.111-126
    • /
    • 2019
  • This paper deals with experimental investigation and modeling of the static behavior of a novel RCS beam-column exterior joint. The studied joint detail is a through-column type in which an H steel profile totally embedded inside RC column is directly welded to the steel beam. The H steel profile was covered by two supplementary plates in the joint area in order to avoid the stirrups resisting shear in the joint area. Two full-scale through-column-type RCS joints were tested under static loading. The objectives of the tests were to examine the connection performance and to highlight the contribution of two supplementary plates on the shear resistance of the joint. A reliable nonlinear 3D finite element model was developed using ABAQUS software to predict the response and behavior of the studied RCS joint. An extensive parametric study was performed to investigate the influences of the stirrups, the encased profile length and supplementary plate length on the behavior of the studied RCS joint.