• 제목/요약/키워드: Commercial Gas Range

검색결과 108건 처리시간 0.023초

업무용대형연소기 안전기준 개선방안 연구 (A Study on Improvement of Safety Standards for Commercial Gas Burning Appliances)

  • 최슬기;안현수;이창언;김영구
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.309-310
    • /
    • 2014
  • Commercial gas burning appliances are classified by KGS AB338. Even though there are many types of gas appliances with different purposes and uses, common standards are applied to the appliances. Manifold of commercial gas range could often be corroded by salt water. Gas leaks and accidents could be occurred by the corrosion. According to suggestion of detailed material standards for manifold of commercial gas range, it could help to use safely and prevent gas accidents.

  • PDF

슬림라인형 가스레인지용 쿡탑형 가스 밸브의 개발과 작동 성능 검증 (The development and Performance test of the Cook Top type Gas valve for the slim-line style Gas Range)

  • 김상주;이상철;주광명;이한종;장인배
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.568-572
    • /
    • 2003
  • The height of valve body is limited to 30mm in the cook-top style gas valves for the domestic gas ranges. But the all the safety specifications of KS should be fulfilled and the magnetic power unit(MPU) should be installed in the valve body for the safety reason. The length of MPU body is longer than the 30mm that it should be located in the square direction of the knob shaft and therefore the implementation of the lever mechanism to transmit the press motion of the knob to the MPU valve is very difficult. In this paper, the hinged lever with inclined plate is used to transmit the press motion of the knob to the MPU valve. The analysis of the gas flow with using the commercial software of FLOW-3D shows that the gas flow capacity is fit for the domestic gas range. The performance and responsibility of the valve is tested for the mass production and the test results shows that the valve can be installed in the commercial gas range.

  • PDF

귀금속계열 WGS 촉매 연구 (Noble metal catalysts for Water Gas Shift reaction)

  • 임성광;배중면;김선영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2228-2231
    • /
    • 2007
  • Water gas shift reactor in fuel processing is an important part that converts carbon monoxide into hydrogen. Fuel processing system for PEMFC usually has two stages of WGS reactors, which are high temperature and low temperature shifter. In this study we prepared noble metal catalysts and compared their performances with that of a commercial iron chromium oxide catalyst. Noble metal catalysts and the commercial catalyst showed quite different temperature dependence of carbon monoxide conversion. The conversion of carbon monoxide at the commercial catalyst was very low at medium temperature(${\sim}300^{\circ}C$) and increased rapidly as temperature increased while the conversion at noble metal catalysts was high in the medium temperature range and decreased as temperature increased, which is thermodynamically expected. Their characteristics agreed well with the literature published, and we are accomplishing further study for improvement of the noble metal catalysts.

  • PDF

폐플라스틱의 열분해 유화기술 개발 (Process Development of Pyrolysis Liquefaction for Waste Plastics)

  • 노남선;신대현;박소원;이경환;김광호;전상구;조봉규
    • 신재생에너지
    • /
    • 제2권2호
    • /
    • pp.118-125
    • /
    • 2006
  • The target of this work was the process development of demonstration plant to produce the high quality alternative fuel oil by the pyrolysis of mixed plastic waste. In the first step of research, the bench-scale units of 70 t/y and the pilot plant of 360 t/y had been developed. Main research contents in this step were the process performance test of pilot plant of 360 ton/year and the development of demonstration plant of 3,000 t/y, which was constructed at Korea R & D Company in Kimjae City. The process performance of pilot plant of 360 t/y showed about 80% yield of liquid product, which was obtained by both light gas oil(LGO) and heavy gas oil(HGO), The boiling point range distribution of LO product that was mainly consisting of olefin components in PONA group appeared at between that of commercial gasoline and kerosene. On the other hand, HO product was mainly paraffin and olefin components and also appeared at upper temperature distribution range than commercial diesel. Gas product showed a high fraction of $C_3\;and\;C_4$ product like LPG composition, but also a high fraction of $CO_2$ and CO by probably a little leak of process.

  • PDF

바이오 가스를 연료로 사용하는 증기분사 가스터빈 열병합발전 시스템의 성능분석 (Performance evaluation of a steam injected gas turbine CHP system using biogas as fuel)

  • 강도원;강수영;김동섭;허광범
    • 한국유체기계학회 논문집
    • /
    • 제13권6호
    • /
    • pp.57-62
    • /
    • 2010
  • MW-class gas turbines are suitable for distributed generation systems such as community energy systems(CES). Recently, biogas is acknowledged as an alternative energy source, and its use in gas turbines is expected to increase. Steam injection is an effective way to improve performance of gas turbines. This study intended to examine the influence of injecting steam and using biogas as the fuel on the operation and performance a gas turbine combined heat and power (CHP) system. A commercial gas turbine of 6 MW class was used for this study. The primary concern of this study is a comparative analysis of system performance in a wide biogas composition range. In addition, the effect of steam temperature and injected steam rate on gas turbine and CHP performance was investigated.

Optical Purity Determination of (S)-Ibuprofen in Tablets by Achiral Gas Chromatography

  • Paik, Man-Jeong;Kim, Kyoung-Rae
    • Archives of Pharmacal Research
    • /
    • 제27권8호
    • /
    • pp.820-824
    • /
    • 2004
  • An optical purity test was indirectly performed on (S)-ibuprofen as its diastereomeric (R)-(+)-1-phenylethylamide derivative using achiral gas chromatography (GC). The method for the determination of trace (R)-ibuprofen (optical impurity), within the range 1.0 to 50 ng, from a racemic ibuprofen standard was linear (r=0.9997) with acceptable precision (% $RSD{\leq}5.3$) and accuracy (% RE=0.7~-3.9). Similar results were obtained with the method validation for the quantification of (S)-ibuprofen within the range 0.1 to 2.0 $\mu\textrm{g}$ using a (S)-ibuprofen stan-dard. When applied to seven different commercial (S)-ibuprofen products, their optical purities (98.7~99.1%) were determined with good precision (% $RSD{\leq}4.0$).

활성화 공정을 경유한 폐각의 흡착특성 (Adsorption Characteristics of Oyster Shell using Activation Process)

  • 이승범;홍인권
    • 공업화학
    • /
    • 제19권4호
    • /
    • pp.439-444
    • /
    • 2008
  • 폐각 원료를 수증기 활성화 공정을 거쳐 다공성 흡착제로 제조하여 흡착성능을 평가하였다. 세척 파쇄한 폐각원료를 $600{\sim}1000^{\circ}C$로 탄화시킨 후 $700{\sim}800^{\circ}C$의 회전로에 주입하는 수증기 활성화법에 의해 활성화공정을 수행하였다. 다양한 조건으로 제조된 폐각흡착제 중 $1000^{\circ}C$로 탄화시켜 제조된 흡착제가 다른 공정으로 제조된 흡착제에 비해 흡착능이 높게 나타났다. 또한 기상흡착과 액상흡착실험을 통해 흡착제로서의 활용가능성을 확인한 결과 기상흡착의 경우에는 기존 흡착제에 비해 현저히 떨어진 성능을 나타내었으며, 액상흡착의 경우에는 흡착질로 benzene을 선정한 경우 다른 상용 흡착제와 비교하여 거의 유사한 흡착특성을 나타내어 흡착제로서의 활용가능성을 확인할 수 있었다.

NGH 수송기술 개발을 위한 주요 인자별 제조특성 실험 연구 (An Experimental Investigation on Effects of Gas Hydrate Formation Factors For NGH Transport Technology Development)

  • 김유나;신창훈;한정민;신광식;김병주;이정환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.511-514
    • /
    • 2007
  • Gas hydrate has a unique property that can store a large volume of gas in water as a solid form. Even though investigations for natural gas storage technology have been carried out for several decades, there are still a lot of unsolved problems due to complex formation process, low formation speed, high energy consumption and so on. So, lots of experiments were conducted to overcome these weaknesses and to develop artificial NGH formation technology applicable to industrial-scale storage and commercial transport. In this study, some series of experiments were performed to analyze both stirred and unstirred system especially about the influences of several gas hydrate formation factors such as agitation speed, system temperature, SDS concentration, etc. As a result, optimum range of SDS concentration and temperature that could enhance the storage capacity and shorten the formation time were found. And it is obviously presented that SDS such a kind of surfactant promotes gas hydrate formation dramatically and the quantity of stored gas are proportional to agitation speed in stirred system.

  • PDF

고압 밀폐 가스 스프링에서의 열전달 효과 수치해석 및 실험적 검증 (The Numerical Analysis and Experimental Verification of the Heat Transfer Effect on the Highly Pressurized Gas Spring)

  • 한인식;최교준;김재용;이윤복
    • 한국자동차공학회논문집
    • /
    • 제21권2호
    • /
    • pp.87-97
    • /
    • 2013
  • Recently the use of gas spring in the combat and commercial vehicle's suspension is increasing. Because of its nonlinear characteristics, the gas spring can support wide range of dynamic loads and gives good ride quality. In design of gas spring, isothermal and adiabatic processes are applied generally, but those processes could not produce heat transfer effect in the simulation. So in this study, heat transfer differential equation and BWR/Ideal state equation are used to calculate the pressure of gas spring which is changing with time. The numerical analysis showed that the pressure of gas spring forms a hysteresis loop in the both of the state equations. But the peak pressure value of BWR equation over 0.1Hz frequency are higher than that of adiabatic process. And the test results showed that the differences between test results and ideal gas equation are smaller than those of BWR equation, so the ideal equation is more accurate than BWR equation in this case.

회분식 유동층 반응기에서 촉매함량 변화에 따른 WGS 촉매의 반응특성 (Reaction Characteristics of WGS Catalyst with Fraction of Catalyst in a Batch Type Fluidized Bed Reactor)

  • 류호정;현주수;김하나;황택성
    • 한국수소및신에너지학회논문집
    • /
    • 제22권4호
    • /
    • pp.465-473
    • /
    • 2011
  • To find the optimum mixing ratio of WGS catalyst with $CO_2$ absorbent for SEWGS process, water gas shift reaction tests were carried out in a fluidized bed reactor using commercial WGS catalyst and sand (as a substitute for $CO_2$ absorbent). WGS catalyst content, gas velocity, and steam/CO ratio were considered as experimental variables. CO conversion increased as the catalyst content increased during water gas shift reaction. Variations of the CO conversion with the catalyst content were small at low gas velocity. However, those variations increased at higher gas velocity. Within experimental range of this study, the optimum operating condition(steam/CO ratio=3, gas velocity = 0.03 m/s, catalyst content=10 wt.%) to get high CO conversion and $CO_2$ capture efficiency was confirmed. Moreover, long time water gas shift reaction tests up to 20 hours were carried out for two cases (catalyst content = 10 and 20 wt.%) and we could conclude that the WGS reactivity at those conditions was maintained up to 20 hours.