• Title/Summary/Keyword: Commercial Inverter

Search Result 85, Processing Time 0.034 seconds

Countermeasure on the Suppression of Micro Surge and Noise for a Induction Motor Driven by Commercial Inverter (상용인버터 구동 유도전동기의 마이크로 서지 및 노이즈 억제에 관한 대책)

  • Kim, Duk-Hyun;Choi, Jeong-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.111-117
    • /
    • 2008
  • Generally, speed control for Induction motor widely used in industrial field is accomplished by commercial inverter. Induction motor driven by commercial inverter causes the micro surge voltage because of high speed switching of inverter. Micro surge brings about not only the breakdown of motor but also noise in PLC control system. And they court the enormous interference in activity for production. In this paper, we suggest the suppressible countermeasure for the breakdown of motor after the consideration of productive mechanism about micro surge. Experiment is performed by inverter with LCR filler in its output terminal. As a result, we confirmed that micro surge voltage is reduced. And the suppressible countermeasure for the noise of PLC control system is suggested by theoretical consideration.

The Characteristic of Inverter Control by Variation of Refrigeration Load and Outdoor Temperature on Industrial Cooler (외기온도와 부하변화에 따른 산업용 냉각기의 인버터제어 특성)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.150-155
    • /
    • 2014
  • This paper presents The performance analysis of inverter control type-industrial cooler with respect to refrigeration load and outdoor temperature. Aside from materials about simulations and foundation data regarding inverter control compressors, currently, data about commercial coolers with inverter control still lack information for performance comparison. Thus, in this paper, the experiments are done to see characteristics of condensation capacity, evaporation capacity, compressor power and COP with respect to outdoor temperature and load by using a commercial inverter control cooler model. As a result, COP difference of the inverter control cooler with respect to load is 30% at the outdoor temperature of $35^{\circ}C$, 29% at the outdoor temperature of $30^{\circ}C$, 34% at $25^{\circ}C$, respectively.

The New Active Voltage Clamp ZVS-PWM Resonant High-frequency Inverter (새로운 액티브 전압 클램프 ZVS-PWM 공진 고주파 인버터)

  • Ahn, Yong-Wie;Kim, Hong-Shin;Mun, Sang-Pil;Woo, Kyung-Il;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.188-193
    • /
    • 2017
  • In this paper, a ZVS-PWM high-frequency inverter with a PWM control function is applied to commercial system 220[Vrms], and a resonator type ZVS-PWM high-frequency inverter circuit with a fixed-two methods were proposed. The parameters of the transformer model equivalent circuit of a copier fixing device, which is an essential element in the parameter optimization of the proposed circuit, are obtained by using a high-frequency amplifier and its frequency characteristics are described. The proposed method compared to the existing single-ended ZVS-PFM high frequency inverter can suppress the voltage and current peak value of the power semiconductor switching device and reduce the switching loss. The efficiency of the proposed method itself is 98[%] at rated power output. Also, the efficiency of 96[%] can be obtained even at low output, so that the proposed high frequency inverter is very efficient inverter. The total efficiency from the commercial AC input to the inverter output is 93[%] at rated, which is considered efficient for use in copying machines. In addition, the diode bridge loss accounts for the largest portion of the overall system efficiency distribution. On the other hand, the nonparallel filter has a very low loss.

Signal Analysis of Inverter-Type Outdoor Unit for Detecting Operation Changes of Commercial Refrigerator (상업용 냉장고의 상황 감지를 위한 인버터형 실외기 신호 분석)

  • Lim, Hyo Joon;Lee, Ju Kyoung;Hwang, Jun Hyeon;Lee, Kyung Chang;Lee, Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.6
    • /
    • pp.517-523
    • /
    • 2016
  • Unlike household refrigerators, commercial refrigerators are composed of separate indoor and outdoor units. The outdoor unit of most commercial refrigerators is designed to run at a fixed speed, which results in low energy efficiency and loud fan noise. Moreover, it cannot respond flexibly to changing thermal load in the indoor unit. Inverter type outdoor units can address such problems through speed changes based on information obtained from the indoor unit. However, using two units from different manufacturers is often not a viable solution. If condition changes in the indoor unit can be detected without communication between the two units, it is possible to adjust the speed of the outdoor unit. This paper attempts to analyze the signal from the outdoor unit when the condition of the indoor unit changes by varying the thermal load.

A Study on about Implementation to Induction Cooker that load Turbo Inverter algorithm

  • Lee Min-Ki;Koh Kang-Hoon;Kwon Soon-Kurl;Lee Hyun-Woo;nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.136-139
    • /
    • 2001
  • The voltage resonating inverter has a defect in the switching element that works at 5 or 6 times higher than input voltage. Especially, it is very difficult to choose very high switching device for the 220[V]commercial voltage. In this paper, it is proposed the optimum method to realize the turbo 2000[W] power for induction cooker that is employed the 900[V] IGBT with decreasing operating voltage of the switching component by making the 220[V], 1500[W] inverter through the clamp mode voltage resonating inverter.

  • PDF

Clinical Application of Inverter type X-ray Generator (Inverter 방식(方式) X선장치(X線裝置)의 임상응용(臨床應用))

  • Lee, Sun-Sook;Huh, Joon;Lee, Jea-Won;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.107-113
    • /
    • 1992
  • Inverter type X-ray apparatus has been introduced and used several hospitals. Principle of inverter type X-ray generators are such as to convert the frequency of commercial power supply to high frequency and to control the high voltages for X-ray tube. Inverter generators are now on the way for futher development to elliminate single phase generators and three phase generators. We compared inverter type X-ray apparatus with conventional single phase 2 peak and three phase 12 peak, apparatus in the following aspects X-ray out put to tube voltage, linearity of X-ray out put to mA, HVL according to mA contrast to kV.

  • PDF

A Study on Performance Test of a Photovoltaic System Inverter using Real Time Digital Simulator (RTDS) (RTDS 시험모듈을 이용한 태양광 인버터의 성능시험에 관한 연구)

  • Kim, Eung-Sang;Kim, Seul-Ki;Jeon, Jin-Hong;Ahn, Jong-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.325-333
    • /
    • 2007
  • A PV system inverter test module using RTDS was developed and performance test of a commercial PV inverter was carried out. The developed module consists of one RTDS hardware rack, RTDS software models representing PV array and simple distribution system, and two power amplifiers that was specifically designed for generating power corresponding to signals from RTDS. Performance test results verified effectiveness and reliability of the test module. It is expected that the developed test module may help PV inverter manufacturers improve ana test their systems in the developing stage.

A Study on commercial frequency source with ZCS type high frequency resonant Inverter

  • Kim, Jong-hae;Kim, Dong-Hee;Bae, Sang-Jun
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.1030-1035
    • /
    • 1998
  • This paper describes a new dc-ac inverter system, which for achieving sinusoidal ac waveform make use of parallel loaded frequency resonant inverter consisting of full bridge. Each one of the pair of switches in the inverter is driven to synchronous output frequency and the other is driven to PWM signal with resonant frequency proportional to magnitude of sine wave. Since current through switches is always zero at its turn-on in proposed inverter, low stress and low switching loss is achieved. The theoretical analysis is proved through the experimental test.

  • PDF

A Study on about Implementation to Microwave Oven that Load Turbo Inverter algorithm (터보 인버터 알고리즘을 탑재한 전자레인지 구현에 관한 연구)

  • Lee, Min-Ki;Koh, Kang-Hoon;Kwon, Soon-Kurl;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.205-207
    • /
    • 2001
  • In response to this inverter microwave oven has been developed to improve high speed cooking time & energy saving performance. The voltage resonating inverter has a defect in switching element that works at 5 or 6times higher than input voltage. Especially, it is very difficult to choose the switching device is very high for the 220 (V) commercial voltage. In this paper, it is proposed the optimum method to realize the turbo 1200(W) output power for microwave oven that is employed the 900(V) IGBT with decreasing operating voltage of the switching component by making the 220(V), 1000(W) inverter through the active clamp voltage resonating inverter.

  • PDF

Electric Fan Heater Design for Eco-Energy Saving (친환경 에너지 절감형 전기온풍기 기구설계)

  • Sul, Yong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.474-479
    • /
    • 2016
  • As the Eco-energy is recently required, electrical energy is fast increased. Several induction heating methods are attractive for Eco-energy and energy saving. In this paper, electrical fan heater was designed and developed with new concept for energy saving by electromagnetic induction heating. Proposed system was composed of three module, blast part, induction heating part and power transformation part. Induction heating method was adapted for heating and the resonant inverter was used for increasing of the power transformation efficiency. Full-bridge resonant inverter was adopted to resonant inverter. This system was composed of induction heating part made with metal(SUS 40 series), and power transformation part made with rectifier module, filter module and resonant inverter. From these results, the proposed new electric heater could be saved the energy from faster increasing the temperature compared to commercial gas and other electric heater. This electrical fan heater is possible to be used in field of home, commercial and agricultural area for eco-energy saving heater.