• Title/Summary/Keyword: Compensation factor

Search Result 597, Processing Time 0.031 seconds

Body compensation image on power shoulder raglan sleeve jacket according to the shoulder height and width (파워 숄더 래글런 슬리브 재킷의 어깨 높이와 너비 변화에 따른 신체 보정 이미지)

  • Lee, Si-Baek;Suh, Mi-A;Uh, Mi-Kyung
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.1
    • /
    • pp.117-125
    • /
    • 2015
  • The purpose of this study is to evaluate the differences of body compensation image on variations in the shoulder height and width of power shoulder raglan sleeve jacket. Nine samples were examined: 3 variations of the shoulder height and 3 variations of the shoulder width. The data was evaluated by 123 fashion design majors. The results were as follows; as a result of analyzing the body compensation image according to changes in the shoulder height and width of power shoulder raglan sleeve jacket, five factors were selected; the shoulder compensation factor, the bust compensation factor, the waist compensation factor, the arm compensation factor and the neck compensation factor. Among these factors, the shoulder compensation factor is the most important factor. Examining the major effect of the body compensation image based on changes in the shoulder height and width of power shoulder raglan sleeve jacket, it had an independent influence on factors about waist, neck, shoulder and arm compensation except a factor about bust compensation, had an influence on interacting effect of factors about shoulder, bust, waist, arm compensation, and it had no influence on interacting effect of a factor about neck compensation. This shows that the shoulder height has larger effect on neck compensation image than the shoulder width in power shoulder raglan sleeve jacket.

Development of Voltage Controlled Power Factor Compensation System using Slidac (슬라이닥을 이용하는 전압 제어 방식의 역률보상시스템 개발)

  • Joung, Sanghyun;Lee, Hyun-woo;Park, Young-kyun;Park, Chul-woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.8
    • /
    • pp.115-122
    • /
    • 2017
  • In this paper, we propose a novel power factor compensation system using slidac. The proposed power factor compensation system compensates the power factor by adjusting the output voltage of the slidac. In the conventional power factor compensation system using capacitor bank method, the power factor compensation error occurs depending on the load condition due to the limitation of the compensation capacitor capacity. However, the proposed system can finely change slidac output voltage applied to the capacitor, therefore power factor can be compensated up to 100% without error. We compare the proposed system with the conventional system, and confirm that the proposed system has excellent power factor compensation performance through simulations and experiments. If the proposed power factor compensation system is applied to an industrial field, a power factor compensation performance can be maximized. As a result, it is possible to reduce of electricity prices, reduce of line loss, increase of load capacity, ensure the transmission margin capacity, and reduce the amount of power generation.

Power Factor Compensation System based on Voltage-controlled Method for 3-phase 4-wire Power System (3상 4선식 전력계통에서 전압제어 방식의 역률보상시스템)

  • Park, Chul-woo;Lee, Hyun-woo;Park, Young-kyun;Joung, Sanghyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.8
    • /
    • pp.107-114
    • /
    • 2017
  • In this paper, a novel power factor compensation system based on voltage-controlled method is proposed for 3-phase 4-wire power system. The proposed voltage-controlled power factor compensation system generates a reactive power required for compensation by applying a variable output voltage by a slidac to a capacitor. In conventional power factor compensation system using the capacitor bank method, the power factor compensation error occurs depending on the load condition due to the limited capacity of the capacitors. However, the proposed system compensates the power factor up to 100% without error. In this paper, we have developed a voltage-controlled power factor compensation system and a control algorithm for 3-phase 4-wire power system, and verify its performance through simulation and experiments. If the proposed power factor compensation system is applied to an industrial field, a power factor compensation performance can be maximized. As a result, it is possible to reduce of electricity prices, reduce of line loss, increase of load capacity, ensure the transmission margin capacity, and reduce the amount of power generation.

Voltage Drop and Power Factor Compensation Relation of Induction Motor applied to Logistics System (물류 시스템 적용 유도전동기의 전압강하와 역률 보상 관계)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.155-159
    • /
    • 2018
  • Recently, the expansion or establishment of facilities for the logistics system is increasing. Conveyor facilities play a major role in sorting and transporting logistics. Induction motors are widely used for the operation of these conveyor systems. In the logistics system, a large number of induction motors are used. These motors have a considerable distance from the power source side and have a low power factor. The installation position for the power factor compensation of the induction motor is very important. Since the voltage drop depends on the length of the line, it is an important parameter in capacitor capacity determination for power factor compensation. The capacity of the capacitors installed to compensate the power factor of the inductive load should be designed to the extent that self-excitation does not occur. In this study, we analyze the method of compensating the proper power factor considering the voltage drop and the installation position of the induction motor in the logistics system.

Image differences based on changes in hip circumference and crotch length in baggy pants - Focused on women in their 20s - (배기팬츠 엉덩이둘레 여유분과 밑위길이 여유분 변화에 따른 시각적 이미지 - 20대 여성을 중심으로 -)

  • Choi, Eunju;Suh, Mi-A;Uh, Mi-Kyung
    • The Research Journal of the Costume Culture
    • /
    • v.20 no.6
    • /
    • pp.912-922
    • /
    • 2012
  • With a long crotch length and much ease in the hip area, baggy pants are visually expressed in a variety of designs when compared with regular pants. The purpose of this study is to define the image differences of various baggy pants designs according to hip circumference and crotch length ease. To that end, this study deduced the visual image variable of experimental baggy pants and analyzed visual images according to changes in hip circumference and crotch length. Nine baggy pants with different levels of hip circumference and crotch length ease were produced as experimental pants. The image of each pair of experimental baggy pants was evaluated based on pictures taken of the pants worn by a woman in her 20s with a standard body figure. The image assessment team was composed of 105 clothing majors. The research results are as follows. Four visual image factors of experimental baggy pants were extracted: whole body compensation, lower body compensation, hip compensation, and waist compensation. Among the 4 factors, the whole body compensation factor was shown as the most representative factor. The body compensation image was higher with less hip circumference ease in the experimental baggy pants, and more hip circumference ease created the optical illusion of a larger body figure, presenting a significant difference between waist circumference and hip circumference. The lower body compensation factor, hip compensation factor, and waist compensation factor all showed a significant influence on changes in hip circumference ease. This result shows that changes in hip circumference ease exerted more influence on the body compensation image than did changes in crotch length ease. The results of this study provide basic data for predicting visual images according to differences in the level of ease in baggy pants, helping people select clothing suitable to their preferences and body shapes.

Effects of the KMS Adoption Factor and the Compensation Factor on the Business Performance of Public Organization (공공분야의 지식관리 시스템 도입요인과 보상요인이 성과에 미치는 영향)

  • Ku, Byeong-Kwan;Yi, Seon-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.418-429
    • /
    • 2012
  • In this research, we analyzed empirically whether the valuation and compensation factor being moderating variable played the role of adjuster between KMS adoption factor(organizational factor, knowledge Informational factor, user factor) and business performance. The results of this research are as follows. First, The valuation and compensation factor affects the usage of KMS in case of organization's flexibility, trust, suitability of knowledge, degree of functional provision and perceived benefit. But it does not affect the usage of KMS in case of easiness of usage and user expertise. Second, The valuation and compensation factor affects the user's satisfaction of KMS in case of organization's flexibility, trust, degree of functional provision and user expertise. But it does not affect the user's satisfaction of KMS in case of suitability of knowledge, easiness of usage and perceived benefit.

A Characteristic Study on the Power Factor Compensation Application of High Voltage Induction Motor (고압 유도전동기 역률 보상설비의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.225-230
    • /
    • 2008
  • Reactor starting method has the advantage of simplicity and closed transition in spite of lower starting torque per kVA. This method allows a smooth start with almost no observable disturbance on transition and is suitable for applications such as centrifugal pumps or fans. Reactive power doesn't contribute to work but needs to sustain the electromagnetic field required for the induction motor to operate. Starting power factor of induction motor is specially lower than running power factor. Power factor application is needed to compensate for the lower power factor of induction motor. This power factor compensation systems is occasionally being hit by the effects of the starting reactor connection position at the starting, stopping of high-voltage induction motor. This paper describes voltage and current stress affected by the installation position of power factor compensation application at the reactor starting method.

Research on Grid Side Power Factor of Unity Compensation Method for Matrix Converters

  • Xia, Yihui;Zhang, Xiaofeng;Ye, Zhihao;Qiao, Mingzhong
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1380-1392
    • /
    • 2019
  • Input filters are very important to matrix converters (MCs). They are used to improve grid side current waveform quality and to reduce the input voltage distortion supplied to the grid side. Due to the effects of the input filter and the output power, the grid side power factor (PF) is not at unity when the input power factor angle is zero. In this paper, the displacement angle between the grid side phase current and the phase voltage affected by the input filter parameters and output power is analyzed. Based on this, a new grid side PF unity compensation method implemented in the indirect space vector pulse width modulation (ISVPWM) method is presented, which has a larger compensation angle than the traditional compensation method, showing a higher grid side PF at unity in a wide output power range. Simulation and experimental results verify that the analysis of the displacement angle between the grid side phase current and the phase voltage affected by the input filter and output power is right and that the proposed compensation method has a better grid side PF at unity.

A Study on Optimal Selection of Inductance for Power Factor Improvement of Buck AC/DC LED Driver With Wide Input Voltage Range (입력 전압 범위가 넓은 벅 AC/DC LED 구동기의 역률 개선을 위한 최적 인덕턴스 선택에 관한 연구)

  • Kim, Marn-Go
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.302-305
    • /
    • 2021
  • Selection of the optimal inductance for power factor improvement of a buck AC/DC light-emitting diode (LED) driver with wide input voltage range is described in this study. The power factor change based on the slope compensation is obtained for various normalized output current (NOC) values using discrete-time domain analysis. The possibility of implementing constant slope compensation is described using power factor curves for various NOC values. NOC = 0.5 is chosen for the value of inductance with consideration for the simple implementation and reduction of inductor size. Experimental results of the inductance corresponding to NOC = 0.5 are presented.

Prediction of Autogenous Shrinkage on Concrete by Unsaturated Pore Compensation Hydration Model (불포화 공극 보정 수화도 모델을 이용한 콘크리트의 자기수축 예측)

  • Lee, Chang Soo;Park, Jong Hyok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.909-915
    • /
    • 2006
  • To predict autogenous shrinkage of concrete, unsaturated pore compensation factor could be calculated by experiments of autogenous shrinkage of cement paste on the assumption that the differences between degree of hydration and strain rate of autogenous shrinkage are unsaturated pore formation rate. Applying unsaturated pore compensation factor on modified Pickket model considering contribution factor and non-contribution factor to autogenous shrinkage of concrete, experimental data and existing model were compared. From the results modified Pickket model was verified to present similar tendency between Tazawa model and experimental data, but CEB-FIP model might be corrected because this model uses ultimate autogenous shrinkage underestimated and the same autogenous time function of concrete material properties considering only compressive strength.