• Title/Summary/Keyword: Computed Tomography%28CT%29

Search Result 18, Processing Time 0.027 seconds

CT and MRI image fusion reproducibility and dose assessment on Treatment planning system (치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가)

  • Ahn, Byeong Hyeok;Choi, Jae Hyeok;Hwang, Jae ung;Bak, Ji yeon;Lee, Du hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.33-41
    • /
    • 2017
  • Objectives: The aim of this study is to evaluate the reproducibility and usefulness of the images through the fusion of CT(Computed tomography) and MRI(Magnetic resonance imaging) using a self-manufactured phantom. We will also compare and analyze the target dose from acquired images. Materials and Methods: Using a self-manufactured phantom, CT images and MRI images are acquired by 1.5T and 3.0T of different magnetic fields. The reproducibility of the size and volume of the small holes present in the phantom is compared through the image from CT and 1.5T and 3.0T MRI, and dose changes are compared and analyzed on any target. Results: 13 small hole diameters were a maximum 31 mm and a minimum 27.54 mm in the CT scan and the were measured within an average of 29.28 mm 1 % compared to actual size. 1.5 T MRI images showed a maximum 31.65 mm and a minimum 24.3 mm, the average is 28.8 mm, which is within 1 %. 3.0T MRI images showed a maximum 30.2 mm and a minimum 27.92 mm, the average is 29.41 mm, which is within 1.3 %. The dose changes in the target were 95.9-102.1 % in CT images, 93.1-101.4 % in CT-1.5T MRI fusion images, and 96-102 % in CT-3.0T MRI fusion images. Conclusion: CT and MRI are applied with different algorithms for image acquisition. Also, since the organs of the human body have different densities, image distortion may occur during image acquisition. Because these inaccurate images description affects the volume range and dose of the target, accurate volume and location of the target can prevent unnecessary doses from being exposed and errors in treatment planning. Therefore, it should be applied to the treatment plan by taking advantage of the image display algorithm possessed by CT and MRI.

  • PDF

Efficacy of Positron Emission Tomography in Diagnosing Pulmonary Tumor and Staging of Lung Cancer : Comparing to Computed Tomography (폐종양과 폐암의 병기결정에 대한 양전자단층촬영(PET)의 유용성 -전산화단층촬영 (CT)과의 비교-)

  • 김오곤;조중행;성숙환
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2003
  • Diagnosing and determining the stage of lung cancer by means of positron emission tomography (PET) ha.. been proven valuable because of the limitations of diagnosis by computed tomography (CT). We compared the efficacy of PET with that of CT in diagnosing pulmonary tumor and staging of lung cancer Material and Method: We performed F-18 FDG PET to determine the malignancy and the staging on patients who have been suspicious or were diagnosed as lung cancer by chest X-ray and CT. The findings of PET and of CT of 41 patients (male, 29: female, 12: mean age, 59) were compared with pathologic findings obtained from a mediastinoscopy and thoracotomy. Result: Out of 41 patients, 35 patients had malignant lesions (squamous cell carcinonla 19 cases, adenocarcinoma 14 cases, adenosquamous cell carcinoma 2 cases) and 6 patients had benign lesions. Diagnosing of lung cancer, the sensitivity, specificity and accuracy of CT and PET were the same for two method and the numbers were 100%, 50%, and 92.7% respectively. Eighteen LN groups out of 108 mediastinal LN groups who recieved histologic examination proved to be malignant. Pathologic lymph node (LN) stage was N0-Nl 31 cases, N2 8 cases, N3 2 cases. The correct identification of the nodal staging with CT, PET scans were 31 cases (75.6%), 28 cases (68.3%) respectively. The LN group was underestimated in each 6 cases of CT and PET. In 4 cases of CT and 7 cases of PET, they were overestimated in compare to histologic diagnosis. In the detection of mediastinal LN groups invasion, the sensitivity, specificity and accuracy of CT were 39.8 %, 93.3 %, and 84.3 % respectively. For PET, they were 61.1 %, 90.0 %, and 85.2 %. When two methods considered together (CT+PET), they were increased to 77.8 %, 93.3 %, and 90.7 % respectively. Conclusion: PET appears to be similar to CT in the diagnosis and the nodal taging of pulmonary tumor. Two tests may stage patients with lung cancer more accurately than CT alone.

Usefulness of Preoperative Computed Tomography in Children with Clinically Suspected Appendicitis (소아 충수염 진단에 CT의 유용성)

  • Jun, Si-Youl
    • Advances in pediatric surgery
    • /
    • v.19 no.2
    • /
    • pp.57-65
    • /
    • 2013
  • The entity of negative appendectomies still poses a dilemma in chlidren. Focused computed tomography (CT) scanning has become the diagnostic test of choice in many hospitals. However, the impact of CT scans on the diagnosis in children is unknown exactly. The purpose of this study was to critically evaluate CT scans for the evaluation of acute appendicitis in children, to review utilization of this diagnostic test in our appendicitis population and to determine if diagnostic accuracy has improved. A retrospective analysis of efficacy of CT scan for diagnosis of appendicitis in children was conducted. Children undergoing appendectomy for acute appendicitis were reviewed from 2007 to 2012. Perforation and negative appendectomy (removal of a normal appendix) rates were determined by the final pathologic report. Statistical comparison were made using the $x^2$ test and significance was assigned at p < 0.05. Five hundred four appendectomies were performed. Mean age was $10.1{\pm}3.21$ years, and 62.7% were boys. Overall, 308 children (61.1%) underwent CT scanning, 100 (19.8%) had US performed, and 97 (19.2%) had no radiographic study. A pathologically normal appendix was removed in 8.7% (27 of 308) of CT patients, 9.0% (9 of 100) of US patients, and 11.3% (11 of 97) of patients without a study. The frequency of CT scanning increased from 29.7% (27 of 91) of all children in 2007 to 75.6% (59 of 78) in 2012, whereas utilization of US decreased from 30.8% (28 of 91) to 11.5% (9 of 78). During this time period the difference in the negative appendectomy rate did change significantly from 14% to 6%. Liberal use of CT scans in diagnosing appendicitis in children has resulted in a decreased negative appendectomy rate.

Added Value of Diffusion Weighted Imaging for Detecting Pancreatic Abnormality in Patients with Clinically Suspected Acute Pancreatitis

  • Nam, In Chul;Kim, Seung Ho;Kim, Seon-Jeong;Lim, Yun-jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.241-249
    • /
    • 2016
  • Purpose: To evaluate the added value of diffusion weighted imaging (DWI) to computed tomography (CT) for detecting pancreatic abnormality in patients with clinically suspected acute pancreatitis (AP). Materials and Methods: 203 patients who underwent abdomen CT and subsequent DWI to do a workup for epigastric pain were analyzed. Two blinded radiologists independently performed an interval reading based on CT image sets first, then based on combined CT and DWI image sets. The diagnostic criterion on DWI was the increased signal intensity in the pancreas to that of the spleen. For quantitative analysis, the third radiologist measured ADC value of the pancreas in each patient. Results: For AP (n = 43), the sensitivity for detecting pancreatic abnormality increased, from 42% to 70% for reader 1 (P < 0.05) and from 44% to 72% for reader 2 (P < 0.05). For borderline pancreatitis (n = 42), the sensitivity also increased, from 10% to 26% for reader 1 (P < 0.05) and from 7% to 29% for reader 2 (P < 0.05). The mean ADC values (unit, ${\times}10^{-3}mm^2/s$) were significantly different among the three groups (for AP, $1.09{\pm}0.16$; for borderline pancreatitis, $1.28{\pm}0.2$; for control, $1.46{\pm}0.15$, P < 0.05). Conclusion: Sensitivity for detecting pancreatic abnormality increased significantly after adding DWI to CT in patients with clinically suspected AP.

Computed Tomographic Assessment of Experimentally Induced Legg-Calve-Prethes Disease in Dogs (허혈성 대퇴골두 괴사 유발견에서 전산화 단층 영상 평가)

  • Bae, Sun-Hee;Seong, Yun-Sang;Eom, Ki-Dong;Kim, Jae-Hoon;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.25 no.1
    • /
    • pp.9-14
    • /
    • 2008
  • This purpose of this study was to describe and compare the radiographic and computed tomographic(CT) appearance of the experimentally induced Legg-Calve-Perthes Disease(LCPD) in dogs. LCPD was experimentally induced at the left femoral head in 7 litters of a dog. The lesions were evaluated with radiography, CT, and contrast CT every week from day 7 to day 70 after operation. Histopathologic examination was performed on 92th day after operation. Every images were evaluated according to the staging system of the osteonecrosis published by Association Research of Circulation Osseous in 1997 and the scoring(0-4). On CT scan, diffuse porotic lesion and focal sclerotic lesion were detected on day 14 and on day 21 after operation, respectively. Subchondral fracture, articular collapse and crescent sign with decreased attenuation were shown on day 28 after operation for the first time and no change of the sign were detected from operation day 9 to day 70 after operation. Focal porotic lesion and irregular radiopacity of femoral head were detected on day $41{\pm}7.48$ and on day $51{\pm}5.29$ after operation respectively on radiographs. In scoring evaluation, 2.00 was scored on day 14 after operation on CT scan, on day 56 after operation on radiographs, respectively This study has shown that CT is more suitable for early diagnosis of LCPB and has superior sensitivity than radiography. Also, CT has been expected to be important for staging and treatment of LCPD.

Blush on Computed Tomography and Transcatheter Arterial Embolization in Pelvic Fracture

  • Gwak, Jihun;Yoon, Yong-Cheol;Lee, Min A;Yu, Byungchul;Jang, Myung Jin;Choi, Kang Kook
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.161-166
    • /
    • 2016
  • Purpose: Bleeding is the primary cause of death after severe pelvic fracture. Transcatheter arterial embolization (TAE) is the mainstay of treatment for arterial bleeding. This study aimed to determine the frequency of bleeding by angiography of blush-positive pelvic fractures on computed tomography (CT) images. The bleeding arteries that were involved were investigated by pelvic angiography. Methods: This retrospective cohort study evaluated 83 pelvic fracture patients who were treated in the intensive care unit of the author's trauma center between January 01, 2013 and April 30, 2015. Results: Overall mortality was 9 of 83 patients (10.8%). Blush was observed in 37 patients; blush-positive patients had significantly higher mortality (24.3%) than blush-negative patients (0%). Twenty-four of the 83 patients (28.9%) underwent pelvic angiography. Bleeding was showed in 22 of 24 patients in pelvic angiography. TAE was successfully performed in 21 (95.5%) of the bleeding 22 patients. Angiography was performed in 23 of 37 blush-positive patients, and arterial bleeding was identified in 21 (91.3%). A total 33 bleeding arteries were identified in 22 angiography-positive patients. The most frequent origin of bleeding was internal iliac artery (69.7%) followed by the external iliac artery (18.2%) and lumbar arteries (12.1%). Conclusion: The vascular blush observed in CT scans indicates sites of ongoing bleeding in pelvic angiography. TAE is an excellent therapeutic option for arterial bleeding and has a high success rate with few complications.

The Retrospective Study of Essential X-ray in Emergency Multiple Trauma Patients (응급 다발성 외상환자의 기본적 방사선 촬영부위에 관한 조사연구)

  • Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.51-57
    • /
    • 1996
  • Radiography should be used judiciously and should not delay patients resuscitation. In the patient with emergency multiple trauma, three radiography should be obtained-cervical spine, anteroposterior(AP) chest, and AP pelvis. These examinations can be done in the resuscitation area, usually with a portable X-ray unit, but should not interrupt the resuscitation process. A retrospective study was carried on 157 emergency multiple trauma patients who were admitted to Yong Dong Severance Hospital from January, to December in 1995. I analyzed the types of X-ray examinations in emergency multiple trauma patients, and classified the patients by disoriented group of mentality. The results were as follows: 1. The subjects were 7.1%(157patients) of 2,208 trauma patients(7.3%) in total 30,085 emergency patients. 2. Male to female ratio was 2.57 : 1. The age distribution was highest from 31 years to 40 years(28.0% ). 3. The peak time of patient's entrance in emergency center was between 8 : 00 pm and 2 : 00 am(36.9%), and second peak time was between 2 : 00 pm and 8 : 00 pm (29.3%). 4. According to the injury type, traffic accident, motorcycle accident and falling down were 71.3%, 8.3% and 20.4% respectively. 5. According to the exposure rate of Computed Tomography, chest CT, cervical CT pelvis CT and brain CT were 39.5%, 24.2%, 69.4% and 51.6% respectively.

  • PDF

A Morphometric Analysis of the Foramen Ovale and the Zygomatic Points Determined by a Computed Tomography in Patients with Idiopathic Trigeminal Neuralgia

  • Hwang, Sung-Hyuk;Lee, Myung-Ki;Park, June-Woo;Lee, Jae-Eon;Cho, Chang-Won;Kim, Dae-Jo
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.3
    • /
    • pp.202-205
    • /
    • 2005
  • Objective : The purpose of this study is to measure the dimensions of foramen ovale and to localize the zygomatic point using computed tomography[CT] in Korean adults with idiopathic trigeminal neuralgia. Methods : Facial axial CT scans using the orbitomeatal plane were performed in 67patients [39males and 28females; mean age 58.8years] with idiopathic classic trigeminal neuralgia. We measured the size of the foramen ovale and localized the zygomatic point which was a skin marker over the ipsilateral zygoma that approximates the lateral projection of a straight line joining the centers of the two foramen ovale. Results : The axial dimensions of the foramen ovale on the orbitomeatal plane were of average length : $8.18{\pm}0.82mm$ [range $6.9{\sim}11.5mm$]. width : $4.06{\pm}0.86mm$ [$2.5{\sim}5.7mm$]. The average distance between the external acoustic meatus and the zygomatic point was $21.64{\pm}1.99mm$ [$16.3{\sim}25.0mm$] and the average distance of anterior margin of condylar process of mandible to zygomatic point was $4.29{\pm}1.19mm$ [$1.0{\sim}7.0mm$]. Conclusion : The anatomical understandings including the size of the foramen ovale and localization of the zygomatic point could be helpful in determining a plan of percutaneous approaches to foramen ovale.

Tumor bed volumetric changes during breast irradiation for the patients with breast cancer

  • Chung, Mi Joo;Suh, Young Jin;Lee, Hyo Chun;Kang, Dae Gyu;Kim, Eun Joong;Kim, Sung Hwan;Lee, Jong Hoon
    • Radiation Oncology Journal
    • /
    • v.31 no.4
    • /
    • pp.228-233
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate changes in breast tumor bed volume during whole breast irradiation (WBI). Materials and Methods: From September 2011 to November 2012, thirty patients who underwent breast-conserving surgery (BCS) followed by WBI using computed tomography (CT) simulation were enrolled. Simulation CT scans were performed before WBI (CT1) and five weeks after the breast irradiation (CT2). The tumor bed was contoured based on surgical clips, seroma, and postoperative change. We retrospectively analyzed the factors associated with tumor bed volumetric change. Results: The median tumor bed volume on CT1 and CT2 was 29.72 and 28.6 mL, respectively. The tumor bed volume increased in 9 of 30 patients (30%) and decreased in 21 of 30 patients (70%). The median percent change in tumor bed volume between initial and boost CT was -5%. Seroma status (p = 0.010) was a significant factor in tumor bed volume reduction of 5% or greater. However, patient age, body mass index, palpability, T stage, axillary lymph node dissection, and tumor location were not significant factors for tumor bed volumetric change. Conclusion: In this study, volumetric change of tumor bed cavity was frequent. Patients with seroma after BCS had a significant volume reduction of 5% or greater in tumor bed during breast irradiation. Thus, resimulation using CT is indicated for exquisite boost treatment in breast cancer patients with seroma after surgery.

Evaluation of Scatter Reduction Effect of the Aft-Multiple-Slit (AMS) System Using MC Simulation (MC 시뮬레이션을 이용한 Aft-Multiple-Silt 시스템의 산란선 제거 효과 평가)

  • Chang, Jin-A;Suh, Tae-Suk;Jang, Doh-Yun;Jang, Hong-Seok;Kim, Si-Yong
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.224-230
    • /
    • 2010
  • Purpose: We designed the aft-multiple-slit (AMS) system to reduce scatter in cone-beam computed tomography (CBCT). As a preliminary study, we performed a Monte Carlo N-Particle Transport Code (MCNP) simulation to verify the effectiveness of this system. Materials and Methods: The MCNPX code was used to build the AMS geometry. An AMS is an equi-angled arc to consider beam divergence. The scatter-reduced projection images were compared with the primary images only and the primary plus scatter radiation images with and without AMS to evaluate the effectiveness of scatter reduction. To obtain the full 2 dimensional (2D) projection image, the whole AMS system was moved to obtain closed septa of the AMS after the first image acquisition. Results: The primary radiation with and without AMS is identical to all the slit widths, but the profiles of the primary plus scattered radiation varied according to the slit widths in the 2D projection image. The average scatter reduction factors were 29%, 15%, 9%, and 8% when the slit widths were 5 mm, 10 mm, 15 mm, and 20 mm, respectively. Conclusion: We have evaluated the scatter reduction effect of the AMS in CBCT imaging using the Monte Carlo (MC) simulations. A preliminary study based on the MCNP simulations showed a mount of scatter reduction with the proposed system.