• 제목/요약/키워드: Conformal radiotherapy

검색결과 152건 처리시간 0.024초

비인강암환자에서 시행한 3차원 입체조형 방사선치료의 조기 임상결과 (Initial Experience for 3-D Conformal Boost Treatments in Carcinoma of the Nasopharynx)

  • 장지영;조문준;김기환;송창준;김병국;김준상;김재성
    • 대한두경부종양학회지
    • /
    • 제16권2호
    • /
    • pp.172-176
    • /
    • 2000
  • Objectives: To improve local control and reduce toxicity, 3-D conformal radiotherapy was used as a boost the primary tumor site following fractionated radiotherapy in patients with nasopharyngeal carcinoma. Materials and Methods: Eight patients with previously untreated nasopharyngeal carcinomas were treated with 3-D conformal radiotherapy following fractionated radiotherapy from September 1998 to April 2000. All patients had biopsy confirmation of disease before radiation therapy. Stages were II in 1, III in 5, and IV in 2. Two patients received cisplatin based chemotherapy in addition to radiation therapy; induction chemotherapy in 1, concurrent chemoradiation in 1. 3-D conformal radiotherapy delivered using 6MV Linac as a boost(range 25.2-28.8Gy, median 25.7Gy) following conventionally fractionated radiotherapy(range 50.4Gy). Average total dose ranged from 75.6-79.2Gy(median 76Gy). Follow-up time was 4-21 months(median 9.6 months). Results: Seven of 8 patients were evaluated radiologically within 3 months after completion of radiation therapy. All 7 patients were seen complete remission. One of 7 patients had distant metastasis after 5 months and local failure after 7 months. The tree interval of local recurrence was ranged from 4 - 21 months(median 10.2 months). One patient without radiological evaluation got complete remission clinically. Treatment related toxicity was grade 1-3 xerostomia, dysphagia, and mucositis. During 3-D conformal radiotherapy, there was no aggravation of any toxicity. Conclusion: Although the number of patients was small and follow-up period was short, 3-D conformal radiotherapy following conventional radiotherapy improved tumor control and dose escalation without increased toxicity. Survival and late toxicity should be evaluated through long term follow-up. In addition, it is necessary to confirm the benefits of 3-D conformal radiotherapy in nasopharyngeal carcinoma with randomized trial.

  • PDF

Phase II Study of Docetaxel (Aisu) Combined with Three-dimensional Conformal External Beam Radiotherapy in Treating Patients with Inoperable Esophageal Cancer

  • Shen, Kang;Huang, Xin-En;Lu, Yan-Yan;Wu, Xue-Yan;Liu, Jin;Xiang, Jin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권12호
    • /
    • pp.6523-6526
    • /
    • 2012
  • Objective: This study was designed to investigate treatment efficacy and side effects of concomitant Aisu$^{(R)}$ (docetaxel) with three-dimensional conformal external beam radiotherapy for the treatment of inoperable patients with esophageal cancer. Methods: Inoperable patients were treated with three-dimensional conformal external beam radiotherapy (5/week, 2 GY/day, and total dose 60GY) plus docetaxel ($30-45mg/m^2$, iv, d1, 8). Results: Twenty eight patients met the study eligibility criteria and the response rate was evaluated according to RICIST guidelines. Among 28 patients, 2 achieved CR, 22 PR, 3 SD and 1 patient was documented PD. Mild gastrointestinal reaction and bone marrow suppression were also documented. All treatment related side effects were tolerable. Conclusion: Three-dimensional conformal external beam radiotherapy combined with docetaxel is an active and safe regimen for inoperable patients with esophageal cancer.

Intensity-modulated radiation therapy: a review with a physics perspective

  • Cho, Byungchul
    • Radiation Oncology Journal
    • /
    • 제36권1호
    • /
    • pp.1-10
    • /
    • 2018
  • Intensity-modulated radiation therapy (IMRT) has been considered the most successful development in radiation oncology since the introduction of computed tomography into treatment planning that enabled three-dimensional conformal radiotherapy in 1980s. More than three decades have passed since the concept of inverse planning was first introduced in 1982, and IMRT has become the most important and common modality in radiation therapy. This review will present developments in inverse IMRT treatment planning and IMRT delivery using multileaf collimators, along with the associated key concepts. Other relevant issues and future perspectives are also presented.

식도암의 방사선치료에서 부분 각도에 의한 회전 치료를 이용한 조사체적의 감소 (Decrease of Irradiated Volume using Rotational Treatment by Avoidance Sector in Radiation Therapy for Esophageal Cancer)

  • 황철환;김성후;구재흥;손종기
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.583-592
    • /
    • 2018
  • 세기변조방사선치료와 입체적세기조절회전치료 시 조사체적과 선량 퍼짐 현상을 줄이기 위한 방법으로 조사 각도를 제한하는 부분 각도에 의한 회전치료 기능을 적용하여 표적체적과 주변 정상장기의 선량에 대해 입체조형방사선치료와 비교 분석하였다. 치료계획에 따른 표적체적의 선량분포는 통계적으로 유의한 차이를 확인할 수 없었으며, 폐의 5 Gy(V5) 체적에서 입체조형방사선치료 56.53%, 세기변조방사선치료 52.03%, 입체적세기조절회전치료 47.84%를 나타내어 유의한 차이를 나타내었다(CRT-IMRT p=0.035, CRT-VMAT p<0.001, IMRT-VMAT p<0.001). 10 Gy 체적(V10)에서는 입체조형방사선치료 35.12%, 세기변조방사선치료 34.04%, 입체적세기조절회전치료 33.28%를 보여, 입체조형방사선치료와 세기변조방사선치료(p=0.018), 입체적세기조절회전치료(p=0.035)에서 유의한 차이를 나타내었으나 20 Gy 체적(V20)에서는 유의한 선량 차이를 확인할 수 없었다. 심장의 평균선량과 20 Gy 체적은 치료계획에 따라 유의한 차이를 확인할 수 없었으나, 30, 40 Gy 체적은 입체적세기조절회전치료에서 37.16%, 22.46%를 나타내어 입체조형방사선치료와 비교에서 유의한 차이(p=0.028)를 보였다. 이와 같이 조사체적 감소에 따른 폐의 저 선량 체적(V5, V10)의 감소를 확인할 수 있었으며, 세기변조방사선치료와 입체적세기조절회전치료 시 조사 각도를 일부 제한함으로써 표적체적의 선량분포는 동일하게 유지함과 동시에 조사체적을 줄일 수 있었다. 이로 인해 폐의 선량 퍼짐 현상의 감소로부터 폐의 독성을 낮추는데 기여할 수 있을 것으로 사료된다.

Evaluation of the hybrid-dynamic conformal arc therapy technique for radiotherapy of lung cancer

  • Kim, Sung Joon;Lee, Jeong Won;Kang, Min Kyu;Kim, Jae-Chul;Lee, Jeong Eun;Park, Shin-Hyung;Kim, Mi Young;Lee, Seoung-Jun;Moon, Soo-Ho;Ko, Byoung-Soo
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.241-247
    • /
    • 2018
  • Purpose: A hybrid-dynamic conformal arc therapy (HDCAT) technique consisting of a single half-rotated dynamic conformal arc beam and static field-in-field beams in two directions was designed and evaluated in terms of dosimetric benefits for radiotherapy of lung cancer. Materials and Methods: This planning study was performed in 20 lung cancer cases treated with the VERO system (BrainLAB AG, Feldkirchen, Germany). Dosimetric parameters of HDCAT plans were compared with those of three-dimensional conformal radiotherapy (3D-CRT) plans in terms of target volume coverage, dose conformity, and sparing of organs at risk. Results: HDCAT showed better dose conformity compared with 3D-CRT (conformity index: 0.74 ± 0.06 vs. 0.62 ± 0.06, p < 0.001). HDCAT significantly reduced the lung volume receiving more than 20 Gy (V20: 21.4% ± 8.2% vs. 24.5% ± 8.8%, p < 0.001; V30: 14.2% ± 6.1% vs. 15.1% ± 6.4%, p = 0.02; V40: 8.8% ± 3.9% vs. 10.3% ± 4.5%, p < 0.001; and V50: 5.7% ± 2.7% vs. 7.1% ± 3.2%, p < 0.001), V40 and V50 of the heart (V40: 5.2 ± 3.9 Gy vs. 7.6 ± 5.5 Gy, p < 0.001; V50: 1.8 ± 1.6 Gy vs. 3.1 ± 2.8 Gy, p = 0.001), and the maximum spinal cord dose (34.8 ± 9.4 Gy vs. 42.5 ± 7.8 Gy, p < 0.001) compared with 3D-CRT. Conclusions: HDCAT could achieve highly conformal target coverage and reduce the doses to critical organs such as the lung, heart, and spinal cord compared to 3D-CRT for the treatment of lung cancer patients.

Dosimetric Evaluation of 3-D Conformal and Intensity-modulated Radiotherapy for Breast Cancer after Conservative Surgery

  • Mansouri, Safae;Naim, Asmaa;Glaria, Luis;Marsiglia, Hugo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권11호
    • /
    • pp.4727-4732
    • /
    • 2014
  • Background: Breast cancers are becoming more frequently diagnosed at early stages with improved long term outcomes. Late normal tissue complications induced by radiotherapy must be avoided with new breast radiotherapy techniques being developed. The aim of the study was to compare dosimetric parameters of planning target volume (PTV) and organs at risk between conformal (CRT) and intensity-modulated radiation therapy (IMRT) after breast-conserving surgery. Materials and Methods: A total of 20 patients with early stage left breast cancer received adjuvant radiotherapy after conservative surgery, 10 by 3D-CRT and 10 by IMRT, with a dose of 50 Gy in 25 sessions. Plans were compared according to dose-volume histogram analyses in terms of PTV homogeneity and conformity indices as well as organs at risk dose and volume parameters. Results: The HI and CI of PTV showed no difference between 3D-CRT and IMRT, V95 gave 9.8% coverage for 3D-CRT versus 99% for IMRT, V107 volumes were recorded 11% and 1.3%, respectively. Tangential beam IMRT increased volume of ipsilateral lung V5 average of 90%, ipsilateral V20 lung volume was 13%, 19% with IMRT and 3D-CRT respectively. Patients treated with IMRT, heart volume encompassed by 60% isodose (30 Gy) reduced by average 42% (4% versus 7% with 3D-CRT), mean heart dose by average 35% (495cGy versus 1400 cGy with 3D-CRT). In IMRT minimal heart dose average is 356 cGy versus 90cGy in 3D-CRT. Conclusions: IMRT reduces irradiated volumes of heart and ipsilateral lung in high-dose areas but increases irradiated volumes in low-dose areas in breast cancer patients treated on the left side.

방사선치료 조사영역 내에 발생한 설암 환자에서 입체조형방사선치료 경험 : 증례보고 (Conformal Radiotherapy in a Patient with Cancer at the base of the Tongue in a Previously Irradiated Area)

  • 조문준;김기환;김병국;송창준;김준상;김재성;장지영
    • 대한두경부종양학회지
    • /
    • 제17권1호
    • /
    • pp.59-62
    • /
    • 2001
  • Objectives: We report an interim result of conformal radiotherapy in a patient with early stage cancer at the base of the tongue, which developed in a previously irradiated area. Materials and Methods: A 64-year-old male patient was diagnosed with T4N0M0 supraglottic cancer. He received 72Gy of radiation therapy from 21 November 1988 to 24 February 1989. He had local failure and underwent a salvage total laryngectomy on 28 August 1989. Subsequently, he did well. In early 1999, he suffered from throat pain. He had a 2.5cm ulcerative mass at the base of his tongue, in the area that had been irradiated previously. Biopsy showed squamous cell carcinoma. After workup, he was diagnosed with base of tongue cancer with T2N0M0. Surgery was not feasible because the morbidity was not acceptable. Since it was difficult to re-irradiate the area with a curable dose using conventional 2D radiation therapy with an acceptable morbidity, we decided to try conformal radiotherapy. We used 7 static beam ports with field sizes from $7x6.4\;to\;8x8cm^2$, using 6 and 10MV photons. The fractionation regimen was 1.8Gy, 5 times per week. He received 64.8Gy in 36 fractions from 9 April 1999 to 1 June 1999. Results: In the 21 months since radiotherapy, the patient has not experienced any acute or chronic complications, such as xerostomia. He experienced relief of pain shortly after the start of radiotherapy, showed a complete response, and is still doing well. Conclusion: Conformal radiotherapy can be used to treat cancer that develops within a previously irradiated field, with curative intent.

  • PDF

Dosimetric Comparison between Intensity Modulated Radiotherapy and 3 Dimensional Conformal Radiotherapy in the Treatment of Rectal Cancer

  • Simson, David K;Mitra, Swarupa;Ahlawat, Parveen;Sharma, Manoj Kumar;Yadav, Girigesh;Mishra, Manindra Bhushan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권11호
    • /
    • pp.4935-4937
    • /
    • 2016
  • Objective: To compare dosimetric parameters of 3 dimensional conformal radiotherapy (3 DCRT) and intensity modulated radiotherapy (IMRT) in terms of target coverage and doses to organs at risk (OAR) in the management of rectal carcinoma. Methods: In this prospective study, conducted between August 2014 and March 2016, all patients underwent CT simulation along with a bladder protocol and target contouring according to the Radiation Therapy Oncology Group (RTOG) guidelines. Two plans were made for each patient (3 DCRT and IMRT) for comparison of target coverage and OAR. Result: A total of 43 patients were recruited into this study. While there were no significant differences in mean Planning Target Volume (PTV) D95% and mean PTV D98% between 3 DCRT and IMRT, mean PTV D2% and mean PTV D50% were significantly higher in 3 DCRT plans. Compared to IMRT, 3 DCRT resulted in significantly higher volumes of hot spots, lower volumes of cold spots, and higher doses to the entire OAR. Conclusion: This study demonstrated that IMRT achieves superior normal tissue avoidance (bladder and bowel) compared to 3 DCRT, with comparable target dose coverage.

Chemotherapy and Late Course Three Dimensional Conformal Radiotherapy for Treatment of Patients with Stage III Non-small Cell Lung Cancer

  • Liu, Yang-Chen;Zhou, Shao-Bing;Gao, Fei;Ye, Hong-Xun;Zhao, Ying;Yi, Xiao-Xiang;Huang, Xin-En;Xiang, Jin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권4호
    • /
    • pp.2663-2665
    • /
    • 2013
  • Objective: To compare the efficacy and complications of chemotherapy and late course three-dimensional conformal radiotherapy (3DCRT) in treating patients with stage III non-small cell lung cancer (NSCLC). Patients and Methods: All patients were divided into two groups: to receive chemotherapy and late course 3DCRT (3DCRT group), or chemotherapy and conventional fraction radiation (control group). In the 3DCRT-group, patients were given 6~15 MV X-rays with a total dose of 40 Gy, followed by 3DCRT, 2.5 Gy~3.0 Gy per fraction, 1 fraction/every day, total 68 Gy~70 Gy; in the control group, with conventional fraction radiation the total dose was 64~66 Gy. The chemotherapy regimen in both cases was EP (VP-16 and DDP). Results: Sixty four patients with stage III NSCLC were divided into two groups: 32 patients into 3DCRT, 32 into the control group. One and 2-year survival rates in 3DCRT and control group were 87.5%, 56.3%mad 65.6%, 34.4%, respectively (P<0.05); local control rates were 90.6%, 81.3% and 65.6%, 53.1%, respectively (P<0.05). Conclusion: Chemotherapy and late course 3DCRT is associated with improved survival rate in patients with stage III NSCLC with good tolerability.