• Title/Summary/Keyword: Connection method

Search Result 2,927, Processing Time 0.035 seconds

The Study on Compressive Behavior of Connection Member between Steel Pipe Pile and Concrete Footing (강관말뚝 기초 두부 연결부의 압축거동에 관한 연구)

  • Youn, IL-Ro;Hong, Ki-Nam
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.3
    • /
    • pp.183-190
    • /
    • 2006
  • Generally, application of steel pile as deep foundation member needs specials requirement for the connection method between steel pipe and concrete footing. To investigate real compressive behavior of connection member between steel pipe pile and concrete footing, three specimens were tested with carefully designed experimental system. Main test variable is the connection method between steel pipe pile and concrete footing. The bolted bonding method and hook bonding method was considered as the connection method in this study. From the test results gained from experiment, it was conformed that two types of connection method have the almost same compressive resistance capacity. Therefore, we can conclude that these two connection methods can be used as the strengthening method to verify the compressive composite action of concrete and steel pipe pile.

  • PDF

Combination-mode BLE Device Profile for Connection & Non-connection Methods

  • Jiang, Guangqiu;Joe, Inwhee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.897-899
    • /
    • 2016
  • In recent years, BLE technology has received extensive attention and has been applied to all aspects of life. The existing BLE device has two methods, one is the connection method, and the other is a non-connection method. The representative profile of the connection method is the proximity file. The most typical example of Non-connection method BLE device is a beacon. However, they are both independent and have their own shortcomings. Connection method device can provide service for only one user, others can't use. Security performance of Non-connection method BLE device is poor and the device can't be controlled by the user. In this paper, a combination-mode BLE device profile design scheme is presented, which combines with the previous two methods, and solves the defaults. And We define a dual purpose advertising package that can be used in a normal environment as well as in a disaster environment. Finally, a unidirectional Control idea is proposed. Through performance evaluation, we found that the device has strong stability and low power consumption.

A Study on the Joint Element Connection of Joint Element Structure Method (JES 공법의 JOINT ELEMENT 이음부에 관한 연구)

  • 엄기영;박명준
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.3
    • /
    • pp.133-141
    • /
    • 2002
  • Recently developed JES(Joint Element Structure) Method was researched as a more safe and economic method than other under pass construction method and was applied to many construction sites. The joint element connection of JES Method is the most important factor for the to behavior of structure. The connection of JES method is filled with the mortar, and the steel and mortar of connections produce the same behavior as one material. The results of experience and numerical analysis are following: The maximum internal stress of connection is decided by the end of connection. also, The connection of joint element structure method have sufficient internal stress against fatigue.

Analysis of Deterioration Characteristics for Connection Factor according to Connection Method of Grounding System (접지시스템의 접속방식에 따른 접속요소의 열화특성 분석)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kim, Dong-Ook;Kim, Dong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2126-2127
    • /
    • 2011
  • This paper describes the analysis of deterioration characteristics for connection factor according to connection method of grounding system. The connection method of grounding system is specified in IEC standard. In order to analyze the deterioration characteristics for connection factor, deterioration test was carried out when the connection factor was buried in salt water and underground. The test connection factors were C-type sleeve, clamp, and exothermic welding. As a consequence, most of the connection factor was corroded, and the electrical resistance decreased after deterioration. The analytical results can be used to establish the safety of grounding system.

  • PDF

The developed connection method on Si PV module (결정질 태양전지 모듈의 개선된 Connection Method)

  • Ji, Yang-Geun;Kong, Ji-Hyun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Geun;Han, Deuk-Yeong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.115-120
    • /
    • 2009
  • In this paper, we measurement the resistance on the flat wire for PV module. There is some kind of flat wire that has different length and different contact area in the PV module. so we test the resistance on each case for analysis with common connection method. we measurement the electrical output characteristics and phenomenon of PV module that is applied new connetion method. by the result, The fill factor and electrical output characteristics on PV module are analyzed to getting better more then common connection method. Finally we recommend the developed connection method for diminishing of resistance on PV module. It enhance the electrical character more than common connection method.

  • PDF

Development of Numerical Analysis Model for the Behavior Analysis of Bolted Connection (볼트 접합부의 거동 해석을 위한 수치해석 모델 개발)

  • Kim, Gwang-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.1-9
    • /
    • 2007
  • To analyze the behavior of multiple bolted connection with analytical method, there was a major problem in terms of the number of bolt as two. Multiple bolted connection is wrong in other way, that is impossible to analyze the behavior of connection with various types. So the numerical analysis model was developed to analyze the behavior of connection with various types, and to overcome the limitation of number of bolt. The optimum values for analysis the behavior of multiple bolted connection with numerical methods were obtained as, r=0.35, Kx=137.5, and Ky=257.4. The numerical analysis method was developed in this study showed high efficiency for the existing methods in the behavior analysis of connection.

Topology Optimization of Connection Component System Using Density Distribution Method (밀도분포법을 이용한 부재의 연결구조 최적화)

  • 한석영;유재원
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.4
    • /
    • pp.50-56
    • /
    • 2003
  • Most engineering products contain more than one component. Failure occurs either at the connection itself or in the component at the point of attachment of the connection in many engineering structures. The allocation and design of connections such as bolts, spot-welds, adhesive etc. usually play an important role in the structure of multi-components. Topology optimization of connection component provides more practical solution in design of multi-component connection system. In this study, a topology optimization based on density distribution approach has been applied to optimal location of fasteners such as T-shape, L-shape and multi-component connection system. From the results, it was verified that the number of iteration was reduced, and the optimal topology was obtained very similarly comparing with ESO method. Therefore, it can be concluded that the density distribution method is very suitable for topology optimization of multi-component structures.

Topology Design of Connection Component System Using Density Distribution Method (밀도분포법을 이용한 부재의 연결구조 최적화)

  • 한석영;유재원;박재용
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.15-20
    • /
    • 2003
  • Most engineering products contain more than one component. Failure occurs either at the connection itself or in the component at the point of attachment of the connection in many engineering structures. The allocation and design of connections such as bolts, spot-welds, adhesive etc. usually play an important role in the structure of multi-components. Topology optimization of connection component provides more practical solution in design of multi-component connection system. In this study, a topology optimization based on density distribution approach has been applied to optimal location of fasteners such as T-shape, L-shape and multi-component connection system. From the results, it was verified that the number of iteration was reduced, and the optimal topology was obtained very similarly comparing with ESO method. Therefore, it can be concluded that the density distribution method is very suitable for topology optimization of multi-component structures.

  • PDF

Method of network connection management in module based personal robot for fault-tolerant (모듈기반 퍼스널 로봇의 결함 허용 지원을 위한 네트워크 연결 유지 관리 기법)

  • Choi, Dong-Hee;Park, Hong-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.300-302
    • /
    • 2006
  • Middleware offers function that user application program can transmit data independently of network device. Connection management about network connection of module is important for normal service of module base personal robot. Unpredictable network disconnection is influenced to whole robot performance in module base personal robot. For this, Middleware must be offer two important function. The first is function of error detection and reporting about abnormal network disconnection. Therefore, middleware need method for network error detection and module management to consider special quality that each network device has. The second is the function recovering that makes the regular service possible. When the module closed from connection reconnects, as this service reports connection state of the corresponding module, the personal robot resumes the existing service. In this paper proposed method of network connection management for to support fault tolerant about network error of network module based personal robot.

  • PDF

Dynamic Response Characteristics of Floating Structures According to Connection Types (부유식 구조물의 접합부 형태에 따른 동적응답 특성 연구)

  • Kim, Byoung-Wan;Hong, Sa-Young;Kyoung, Jo-Hyun;Cho, Seok-Kyu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.132-140
    • /
    • 2006
  • This paper investigates the characteristics of dynamic responses of floating structures with connections under sea wave loads. Direct method using higher order boundary element method (HOBEM) and finite element method (FEM) is adopted for numerical analysis. A 500 m-long and 250-m width very large floating structure (VLFS) with four units are considered in numerical analysis. Hinge connection and spring connection with various strength are considered as connection types. Displacements and stresses of VLFS according to the connection types are compared considering wave period and heading angle reduction.