• Title/Summary/Keyword: Contact Treatment

Search Result 1,592, Processing Time 0.033 seconds

FE-analysis of sheet metal forming processes considering continuous contact treatment (연속접촉처리를 고려한 박판성형공정의 해석)

  • Kim T. S.;Yang D. Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.134-137
    • /
    • 2005
  • In this paper, a continuous contact treatment has been considered during FE-analysis of the sheet metal forming processes. Because the simulation is usually performed stepwise, the status of contact can change suddenly. In case of implicit scheme, the increment of punch stroke can be chosen as large value. For exact assessment of contact force and friction force between die and sheet, the continuous contact treatment is proposed. The virtual surface of sheet metal is modeled by NURBS curves or surfaces in order to calculate exact contact area and penetration depth. From the geometrical evaluation of contact behavior, additional contact pressure is imposed to the element. The deformation of bending process and hydroforming process are analyzed based on this scheme.

  • PDF

The Electrical properties of Al/TiN/Ti Contact at Submicron contact(2) (Al/TiN/Ti 전극의 Submicron contact에서의 전기적특성(2))

  • Lee, C.J.;Eum, M.J.;Ra, Y.C.;Kim, S.J.;Sung, M.Y.;Sung, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1069-1071
    • /
    • 1995
  • The electrical properties of Al/TiN/Ti contact are investigated at submicron contacts. The contact resistance and contact leakage current are dependent on metallization, surface dopant concentration, semiconductor surface treatment and contact plug ion implantation. In this paper, the contact resistance and contact leakage current are studied according to surface dopant concentration, semiconductor surface treatment and contact plug ion implantation at 0.8 micron contact. The contact resistance and contact leakage current increases with increasing substrate ion concentration. HF cleaning represents high contact resistance but low contact leakage current while CDE cleaning represents low contact resistance but high contact leakage current. Contact plug ion implantation decreases contact resistance but increases contact leakage current. Specially, RTA represents good electrical properties.

  • PDF

Finite Element Analysis of the Unconstrained Cylindrical Bending Process Considering Continuous Contact Treatment (연속 접촉 처리를 고려한 실린더 벤딩 성형 공정의 유한요소해석)

  • Kim T. J.;Yang D. Y.
    • Transactions of Materials Processing
    • /
    • v.14 no.6 s.78
    • /
    • pp.547-552
    • /
    • 2005
  • In general, the sheet metal and die are described by finite elements for the simulation of the metal forming processes. Because the characteristics as continuum of the sheet metal are represented with triangles and rectangles, the errors occur inevitably in finite element analysis. Many contact schemes to describe the deformation modes exactly have been introduced in order to decrease these errors. In this study, a scheme for continuous contact treatment is proposed in order to consider the realistic behavior of contact phenomena during the forming process. The discrete mesh causes stepwise propagation of contact nodes of the sheet even though the contact region of the real forming process is altered very smoothly. It gives rise to convergence problem in case that the process, for example bending process, is sensitive to the contact between the sheet and the tools. The analysis of the unconstrained cylindrical bending process without blank holder is also presented in order to investigate the effect of the proposed algorithm.

Analysis of the Rolling Contact Fatigue of the Shot Peened Ball Bearing by X-ray Diffraction (X선회절에 의한 SHOT PEENING처리 구름베어링의 구름접촉 피로해석)

  • 이한영
    • Tribology and Lubricants
    • /
    • v.13 no.2
    • /
    • pp.39-45
    • /
    • 1997
  • The shot peening treatment were conducted for improving the strength of rolling contact fatigue of machine element like a gear. This paper was undertaken to analyze the influence of shot peening treatment for inner race of ball bearing on the rolling contact fatigue. Shot peening treatment were applied to the full hardened and the carbonitrided bearing. And the rolling contact fatigue life test and X-ray diffraction test were carried out. The results of this study showed that the fatigue life of ball bearing in the clean and the contaminated oil could be improved by shot peening treatment. This effect was found to be more pronounced to the full hardened bearing. These facts might be due to the generation of compressive residual stress and the strain hardening of surface layer by shot peening treatment. The failure of the shot peened bearing were presumed to initiate at surface.

Effects of lead metal and annealing methods on low resistance contact formation of polycrystalline CdTe thin film (다결정 CdTe박막의 저저항 접축을 위한 배선금속 및 열처리방법의 효과에 관한 연구)

  • 김현수;이주훈;염근영
    • Electrical & Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.619-625
    • /
    • 1995
  • Polycrystalline CdTe thin film has been studied for photovoltaic application due to the 1.45 eV band gap energy ideal for solar energy conversion and high absorption coefficient. The formation of low resistance contact to p-CdTe is difficult because of large work function(>5.5eV). Common methods for ohmic contact to p-CdTe are to form a p+ region under the contact by in-diffusion of contact material to reduce the barrier height and modify a p-CdTe surface layer using chemical treatment. In this study, the surface chemical treatment of p CdTe was carried out by H$\_$3/PO$\_$4/+HNO$\_$3/ or K$\_$2/Cr$\_$2/O$\_$7/+H$\_$2/SO$\_$4/ solution to provide a Te-rich surface. And various thin film contact materials such as Cu, Au, and Cu/Au were deposited by E-beam evaporation to form ohmic contact to p-CdTe. After the metallization, post annealing was performed by oven heat treatment at 150.deg. C or by RTA(Rapid Thermal Annealing) at 250-350.deg. C. Surface chemical treatments of p-CdTe thin film improved metal/p-CdTe interface properties and post heat treatment resulted in low contact resistivity to p-CdTe.Of the various contact metal, Cu/Au and Cu show low contact resistance after oven and RTA post-heat treatments, respectively.

  • PDF

Fabrication of One-Dimensional Graphene Metal Edge Contact without Graphene Exfoliation

  • Choe, Jeongun;Han, Jaehyun;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.371.2-371.2
    • /
    • 2016
  • Graphene electronics is one of the promising technologies for the next generation electronic devices due to the outstanding properties such as conductivity, high carrier mobility, mechanical, and optical properties along with extended applications using 2 dimensional heterostructures. However, large contact resistance between metal and graphene is one of the major obstacles for commercial application of graphene electronics. In order to achieve low contact resistance, numerous researches have been conducted such as gentle plasma treatment, ultraviolet ozone (UVO) treatment, annealing treatment, and one-dimensional graphene edge contact. In this report, we suggest a fabrication method of one-dimensional graphene metal edge contact without using graphene exfoliation. Graphene is grown on Cu foil by low pressure chemical vapor deposition. Then, the graphene is transferred on $SiO_2/Si$ wafer. The patterning of graphene channel and metal electrode is done by photolithography. $O_2$ plasma is applied to etch out the exposed graphene and then Ti/Au is deposited. As a result, the one-dimensional edge contact geometry is built between metal and graphene. The contact resistance of the fabricated one-dimensional metal-graphene edge contact is compared with the contact resistance of vertically stacked conventional metal-graphene contact.

  • PDF

Rolling Contact Fatigue of Hot-forged Steels out of Prealloyed Powders and Powder Blend

  • Dorofeyev, Vladimir;Sviridova, Anna
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.559-560
    • /
    • 2006
  • Powder forging is used for heavy-loaded parts (rings of rolling-contact bearings, gears etc.) production. Rolling contact fatigue is material property values of which characterize possibility of practical utilization of such parts. Rolling contact fatigue of some steels obtained out of prealloyed powders Astaloy CrM, Atomet 4601, Atomet 4901 and powder blends iron-carbon-nickel by hot forging is studied in the present paper. Effect of various kinds of heat and thermomechanical treatment on rolling contact fatigue is determined. Thermomechanical treatment provides optimal values of rolling contact fatigue. In this case steel structure contains up to 40% of retained metastable austenite which is transformed to martensite on trials. Thus typically crack is generated on residual pores and non-metallic inclusions instead of martensite zones in wrought steels.

  • PDF

Electrical characteristics of GaAs MESFET according to the heat treatment of Ti/Au and Ti/Pd/Au schottky contacts (Ti/Au, Ti/Pd/Au 쇼트키 접촉의 열처리에 따른 GaAs MESFET의 전기적 특성)

  • 남춘우
    • Electrical & Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.56-63
    • /
    • 1995
  • MESFETs of the Ti/Au and Ti/Pd/Au gate were fabricated on n-type GaAs. Interdiffusion at Schottky interfaces, Schottky contact properties, and MESFET characteristics with heat treatment were investigated. Ti of Ti/Au contact and Pd of Ti/Pd/Au contact acted as a barrier metal against interdiffusion of Au at >$220^{\circ}C$. Pd of Ti/Pd/Au contact acted as a barrier metal even at >$360^{\circ}C$, however, Ti of Ti/Au contact promoted interdiffusion of Au instead of role of barrier metal. As the heat treatment temperature increases, in the case of both contact, saturated drain current and pinch off voltage decreased, open channel resistance increased, and degree of parameter variation in Ti/Au gate was higher than in Ti/Pd/Au gate at >$360^{\circ}C$ Schottky barrier height of Ti/Au and Ti/Pd/Au contacts was 0.69eV and 0.68eV in the as-deposited state, respectively, and Fermi level was pinned in the vicinity of 1/2Eg. As the heat treatment temperature increases, barrier height of Ti/Pd/Au contact increased, however, decreased at >$360^{\circ}C$ in the case of Ti/Au contact. Ideality factor of Ti/Au contact was nearly constant regardless of heat treatment, however, increased at >$360^{\circ}C$ in the case of Ti/Au contact. From the results above, Ti/Pd/Au was stable gate metal than Ti/Au.

  • PDF

Effects of Centric Relation Splint Therapy on the Occlusal Contact State in Craniomandibular Disorders (교합안정장치 치료가 교합접촉상태에 끼치는 효과)

  • Whan-Cheol Kim;Kyung-Soo Han;Seok-Man Kang
    • Journal of Oral Medicine and Pain
    • /
    • v.18 no.2
    • /
    • pp.71-79
    • /
    • 1993
  • Many types of occlusal splints are used for treatment of craniomandibular disorders. Most widely used splint among them is flat-type centric relation splint. Insertion of splint into the mouth may cause increasing of vertical dimension, masticatory muscle realignment and rearrangement of maxillo-mandibular relationship, so as a result of splint treatment, occlusal relation may vary whether you like it or not. From this point of view, occlusal state of patient shold be frequently monitored to prevent undesired or harmful effect during occlusal splint therapy. The purpose of this study was to investigate the effect of occlusal splint, especially centric relation splint, on the occlusal contact state after 3 months treatment. 32 patients with craniomandibular disorders who had unilateral symptoms participated in this study. To observe and record occlusal contact state, the author used T-Scan system (Tekscan Co. U.S.A.) at both pretreatment and posttreatment. The recorded date were analyzed with regard to contact number, contact force and contact time, change of anterior tooth contact and coincidence of first contact point with affected side were observed, too. Aan last, the subjects were divided into 2 groups and compared, according to average value of VAS index, with respect to joint pain, sound and limitation of movement, respectively. The collected date were statistically processed with SPSS and the result as follows : 1. Total occlusal contact number and force were not changed by occlusal splint therapy but total occlusal contact time decreased slightly. 2. There was a tendency of increasing number of subjects with anterior tooth contact after treatment and change of first contact point side were observed in as many as 40.6% of subjects. 3. There were no difference between higher and lower group of VAS index, and between pretreatment and posttreatment in each group, either.

  • PDF

Effect of DHU001, a Polyherbal Formula, on Dinitrofluorobenzene-induced Contact Dermatitis (Type I allergy)

  • Lee, Hyeung-Sik;Lee, Byung-Chang;Ku, Sae-Kwang
    • Toxicological Research
    • /
    • v.26 no.2
    • /
    • pp.123-130
    • /
    • 2010
  • The effect of DHU001, a mixed herbal formula consisted of 7 types aqueous extracts for various respiratory disorders were evaluated on 2,4-dinitrofluorobenzene (DNFB)-induced contact dermatitis, type I allergic model. Contact dermatitis was induced by sensitization with dinitrophenyl-derivatized ovalbumin (DNP-OVA) and DNFB challenge as antigen. Two different dosages of DHU001 (300 and 150 mg/kg) were orally administered to DNP-OVA sensitization mice once a day for 7 days with reference material, dexamethasone (15 mg/kg, intraperitoneal treatment). End of 7 days oral administration of DHU001 extracts or intraperitoneal treatment of dexamethasone, the changes on the edematous changes and scratching behavior were measured. Immediate after DNFB challenge on ear or paw of DNP-OVA sensitized mice, increases of ear and paw thicknesses and weights were detected with anterior ear skin (dermis to epidermis) thickness and paw scratching behavior increases. However, these contact dermatitis signs induced by DNFB treatment were reduced by treatment of the both different dosages of DHU001 and dexamethasone, respectively. The results obtained in this study suggest that oral treatment of DHU001 extracts also has relatively favorable effects on contact dermatitis.