• Title/Summary/Keyword: Continuous Device

Search Result 583, Processing Time 0.029 seconds

Study on Continuous-Flow Particle Separation in a Microchannel using Dielectrophoresis (마이크로 채널 내에서의 유전영동을 이용한 입자의 연속적인 분리에 대한 연구)

  • Ryu, Jeong-Eun;Kang, Kwan-Hyoung
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.2
    • /
    • pp.56-63
    • /
    • 2010
  • In this work, a dielectrophoresis-based particle-separation device is developed which is to be used to continuously separate particles in microchannels. We fabricated the particle-separation device with combining the benefits of electrode-based DEP and insulator-based DEP. The DEP forces are generated by an array of electrodes located in both sidewalls of a main channel. According to the magnitude and frequency of electrical signals, particles with different dielectric properties experience different DEP forces, and therefore, continuously move along different streamlines in the main flow channel without need of pre-focusing process. Based on this mechanism, we examined the performance of the device by controlling the trajectory of polystyrene particles. This device is applicable to the investigation of dielectric properties of biological cells as well as the continuous separation of biological cells.

Continuous Subcutaneous Administration of Morphine Using Patient Controlled Analgesia Device for Control of Cancer Pain (암성 통증 조절을 위한 자가통증조절장치를 이용한 몰핀의 지속적 피하투여 -증례 보고-)

  • Lee, Kyong-Ho;Lee, Cheol;Kim, Won-Tae
    • The Korean Journal of Pain
    • /
    • v.11 no.2
    • /
    • pp.321-325
    • /
    • 1998
  • Most of the patients with pain resulting from advanced cancer need opioid for adequate analgesia. Various Methods of drug administration to control the pain have been developed. One of them, continuous administration of intravenous morphine is used for more effective pain control in the patient with severe pain that cannot be satisfactorily controlled by other Methods of morphine administration. But this is not a suitable method at home because of the possibility of serious infectious complications and the difficulty in managing intravenous access by untrained personnel. Continuous subcutaneous adminstration of drugs can not only overcome such disadvantages of continuous intravenous infusion but also get almost the same effect of pain control as continuous intravenous infusion, and allows opportunity to move freely and return home, improving quality of life. We used continuous subcutaneous morphine and metoclopramide in the patients with cancer pain via a portable PCA device, and accomplished satisfactory pain relief without significant side effect.

  • PDF

PoMP : Power conscious Multimedia Player (저전력 멀티미디어 재생 기법)

  • Park, Jung-Wan;Won, You-Jip
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04d
    • /
    • pp.253-255
    • /
    • 2003
  • Electricity is the prime commodity in mobile device, e.g. smart phone, PDA, MP3 player and etc. This strict restriction on power consumption requirement of the mobile device puts unique demand in designing hardware and software components of the device. In this paper, we address the issue of minimizing the power consumption in retrieving the continuous media data from the disk drive for real-time playback purpose. Different from the legacy text based data, real-time multimedia playback requires that the storage supplies the data block continuous fashion. This may put immense burden on the power scarce environment since the disk Is required to be active for the entire playback duration. We develop elaborate algorithm which carefully analyzes the power consumption profile of the disk drive and which establishes the data retrieval schedule for the given playback. It computes the amount of data blocks to read, the length of active and standby period. According to our simulation result, the ARM algorithm exhibits superior performance in continuous media retrieval from the aspect of power consumption to legacy playback scheme.

  • PDF

Influence of the deteriorated anti-seismic devices on seismic performance and device behavior of continuous girder bridges

  • Shangtao Hu;Renkang Hu;Menggang Yang;Dongliang Meng
    • Earthquakes and Structures
    • /
    • v.24 no.5
    • /
    • pp.333-343
    • /
    • 2023
  • Various seismic isolation and reduction devices have been applied to suppress the longitudinal vibration of continuous girder bridges. As representative devices, lead rubber bearing (LRB) and fluid viscous damper (FVD) might suffer from deterioration during the long-term service. This study aims to evaluate the impact of device deterioration on the seismic responses of continuous girder bridges and investigate the seismic behavior of deteriorated LRBs and FVDs. Seismic performance of a simplified bridge model was investigated, and the influence of device deterioration was evaluated by the coefficient of variation method. The contribution of LRB and FVD was assessed by the Sobol global sensitivity analysis method. Finally, the seismic behaviors of deteriorated LRBs and FVDs were discussed. The result shows that (i) the girder-pier relative displacement is the most sensitive to the changes in the deterioration level, (ii) the deterioration of FVD has a greater effect on the structural responses than that of LRB, (iii) FVD plays a major role in energy dissipation with a low degradation level while LRB is more essential in dissipating energy when suffering from high degradation level, (iv) the deteriorated devices are more likely to reach the ultimate state and thus be damaged.

Prediction of Pumping Efficacy of Left Ventricular Assist Device according to the Severity of Heart Failure: Simulation Study (심실의 부하감소 측면에서 좌심실 보조장치의 최적 치료시기 예측을 위한 시뮬레이션 연구)

  • Kim, Eun-Hye;Lim, Ki Moo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.22-28
    • /
    • 2013
  • It is important to begin left ventricular assist device (LVAD) treatment at appropriate time for heart failure patients who expect cardiac recovery after the therapy. In order to predict the optimal timing of LVAD implantation, we predicted pumping efficacy of LVAD according to the severity of heart failure theoretically. We used LVAD-implanted cardiovascular system model which consist of 8 Windkessel compartments for the simulation study. The time-varying compliance theory was used to simulate ventricular pumping function in the model. The ventricular systolic dysfunction was implemented by increasing the end-systolic ventricular compliance. Using the mathematical model, we predicted cardiac responses such as left ventricular peak pressure, cardiac output, ejection fraction, and stroke work according to the severity of ventricular systolic dysfunction under the treatments of continuous and pulsatile LVAD. Left ventricular peak pressure, which indicates the ventricular loading condition, decreased maximally at the 1st level heart-failure under pulsatile LVAD therapy and 2nd level heart-failure under continuous LVAD therapy. We conclude that optimal timing for pulsatile LVAD treatment is 1st level heart-failure and for continuous LVAD treatment is 2nd level heart-failure when considering LVAD treatment as "bridge to recovery".

Development and experimental study on cable-sliding modular expansion joints

  • Gao, Kang;Yuan, Wan C.;Dang, Xin Z.
    • Structural Engineering and Mechanics
    • /
    • v.61 no.6
    • /
    • pp.795-806
    • /
    • 2017
  • According to the characteristics of continuous beam bridges, the relative displacement is too large to collision or even girder falling under earthquakes. A device named Cable-sliding Modular Expansion Joints(CMEJs) that can control the relative displacement and avoid collision under different ground motions is proposed. Working principle and mechanical model is described. This paper design the CMEJs, establish the restoring force model, verify the force model of this device by the pseudo-static tests, and describe and analyze results of the tests, and then based on a triple continuous beam bridge that has different heights of piers, a 3D model with or without CMEJs were established under Conventional System (CS) and Seismic Isolation System (SIS). The results show that this device can control the relative displacement and avoid collisions. The combination of isolation technology and CMEJs can be more effective to achieve both functions, but it need to take measures to prevent girder falling due to the displacement between pier and beam under large earthquakes.

Experimental Study on the Seismic Performance of Continuous Bridge Model with Seismic Load Transmitting Devices (지진력 분산장치를 설치한 다경간 연속교의 내진성능향상에 관한 실험연구)

  • 배민혁;김재관;김익현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.409-414
    • /
    • 2003
  • A multi-span bridge model that is fixed in longitudinal direction at a single pier can be very vulnerable to the earthquake ground motion in longitudinal direction. If the seismic load exceeds the capacity of the pier, it can be severely damaged. However, such incident can be prevented if piers of movable support share the seismic load as setting up seismic load transmitting device. This study is performed to investigate seismic performance of continuous bridge model with seismic load transmitting devices which is proposed newly. It is found that continuous bridge model system with device is more effective about displacement control and seismic performance.

  • PDF

Evaluation Method of Hairstyling Materials and its Application to Cosmetic Preparations

  • Abe, Hidetoshi;Iida, Ichiro;Someya, Takao
    • Proceedings of the SCSK Conference
    • /
    • 2003.09a
    • /
    • pp.1-12
    • /
    • 2003
  • Instead of sensory evaluation, we designed an evaluation method of the setting function of hairstyling products, based on an original theory focusing on changes in bending stress observed when a load with continuous bending is applied to human hair. Specifically, we developed a device to measure bending stress to quickly and objectively evaluate the condition of human hair, particularly its dynamic properties such as the setting function, following the application of hairstyling products. This device generates a load with continuous bending while applying a pendulum motion to a hair tress, one end of which is anchored. The setting function and holding power of resins of various molecular weight and ionic properties were evaluated using this device. The results demonstrated a close correlation with those obtained by experts' sensory evaluation. The evaluation results of bending stress and holding rate confirmed that the combined use of two different resins could improve the function of setting preparations. Evaluation using this device was able to substitute for sensory evaluation, and offers quick objective evaluation and detection of changes in the holding power of hairstyling products over time. We conclude that evaluation using this device is a promising new method.

  • PDF

Study Regarding Electronic Paper Technology (전자종이 기술에 관한 연구)

  • Kim, Doh-Gyun;Kang, Soon-Duk
    • The Journal of Information Technology
    • /
    • v.9 no.3
    • /
    • pp.49-57
    • /
    • 2006
  • Electronic paper technology is technology make e- paper, and studying an electronic device is thin like a paper book, an electronic device having made so as to be able to feel as it is feeling of paper like paper newspaper/paper magazines etc. and papers, and crumple freely, or to be able to fold. While electronic paper substitutes for role of paper, a digital function has at the same time a lot of the acids which shall exceed to implement. Necessary, and the continuous researcher who can solve a problem of a fast answer speed for animation implementation, collar implementation and low drive voltage is important a security of a patent right preparing for new market formation, too very in order to form the market where electronic paper can substitute for papers and the existing display as indication elements of a dream, and shall be made to achieve a continuous technical researcher.

  • PDF

A compact and low-power consumable device for continuous monitoring of biosignal (소형화 및 저전력소모를 구현한 실시간 생체신호 측정기 개발)

  • Cho, Jung-Hyun;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.334-340
    • /
    • 2006
  • A compact biosignal monitoring device was developed. Electrodes for electrocardiogram (ECG) and a LED and silicon detector for photoplethysmogram (PPG) were used. A lead II type was arranged for ECG measurement and reflected light was measured at the finger tip for PPG. A single chip microprocessor (model ADuC812, Analog Device) controlled a measurement protocol and processed measured signals. PPG and ECG had a sampling rate of 300 Hz with 8-bit resolution. The maximum power consumption was 100 mW. The microprocessor computed pulse transit time (PTT) between the R-wave of ECG and the peak of PPG. To increase the resolution of PTT, analog peak detectors obtained the peaks of ECG and PPG whose interval was calculated using an internal clock cycle of 921.6 kHz. The device was designed to be operated by 3-volt battery. Biosignals can be measured for $2{\sim}3$ days continuously without the external interruptions and data is stored to an on-board memory. Our system was successfully tested with human subjects.