• Title/Summary/Keyword: Continuous ultrasound

Search Result 91, Processing Time 0.024 seconds

The Effects of Pain and Range of Motion by Continuous Wave Ultrasound and Pulsed Wave Ultrasound on Patient with Temporomandibular Joint Disability (측두하악관절장애 환자에서 연속초음파와 맥동초음파 적용이 통증과 관절가동범위에 미치는 효과)

  • Moon, Hyun-Ju;Seo, Hyun-Kyu;Gong, Won-Tae
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.1-11
    • /
    • 2007
  • Purpose: The purpose of this study was to determine the effect of continuous wave ultrasound and pulsed wave ultrasound that influence changes in pain and range of motion when applied to patients with temporomandibular joint disability. Methods: The subjects of the study were 40 selected patients who had been diagnosed with temporomandibular joint movement restriction and had endured pain for more than two weeks. These patients had visited K orthopedic surgery in Deagu measured from October 1, 2004 to March 31, 2005. The subjects were divided into two groups with 20 patients each. The one group was applied to continuous wave ultrasound and the other group was applied to pulsed wave ultrasound at a dosage of 1.5 W/$cm^2$ for a duration of 5 minutes and eight times for two weeks. The pain perception degree were measured by using Visual Analogue Scale(VAS) and the range of motion was measured by using a rule for each group. Results: The results obtained were as follows The change in the pain perception degree were statistically significant in both group(p<0.05) ; however, the continuous wave ultrasound group showed more difference in the average decrease in the pain perception degree than did the pulsed wave ultrasound group. Both groups showed significant results regarding changed in the range of motion(p<0.05) ; Comparing the difference in the average of the range of motion between the two groups, came back from normal the range of motion of temporomandibular joint at the both groups. Conclusion : Based on the results of this study, we found that both groups showed decreased pain and increased the range of motion, but the continuous wave ultrasound method had a higher therapy effect pain and the range of motion than the pulsed wave ultrasound method to patients with temporomandibular joint disability. With such finding, we expect that according to ultrasound therapy applicant method can be helped usable accurately to patients with variety symptoms temporomandibular joint disability.

  • PDF

The Effects of Ultrasound Irradiation on the Heat Shock Protein 70(HSP70) Expression in Rat Knee Articular Cartilage after Immobilization (흰쥐 슬관절 고정 후 초음파 적용이 관절연골내 HSP70의 발현에 미치는 영향)

  • Nam, Ki-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.3
    • /
    • pp.369-376
    • /
    • 2005
  • The purpose of the study was for investigating the effect of therapeutic ultrasound irradiation on HSP70 expression in knee of degraded rat articular cartilage. Knee of ten Sprague-Dawley male rats were immobilized for 4 weeks and divided at random into the control and continuous ultrasound applicated group. The continuous ultrasound applicated group was irradiated with frequency 1MHz, intensity $1W/cm^2$ for 5 minutes. The control group was sham sonication. The immunoreactivity of HSP70 was increased in degraded articular cartilage after untrasound irradiation. These results suggest that therapeutic ultrasound can enhance HSP70 expression in degraded articular cartilage.

  • PDF

Development and Evaluation of D-Attention Unet Model Using 3D and Continuous Visual Context for Needle Detection in Continuous Ultrasound Images (연속 초음파영상에서의 바늘 검출을 위한 3D와 연속 영상문맥을 활용한 D-Attention Unet 모델 개발 및 평가)

  • Lee, So Hee;Kim, Jong Un;Lee, Su Yeol;Ryu, Jeong Won;Choi, Dong Hyuk;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.195-202
    • /
    • 2020
  • Needle detection in ultrasound images is sometimes difficult due to obstruction of fat tissues. Accurate needle detection using continuous ultrasound (CUS) images is a vital stage of treatment planning for tissue biopsy and brachytherapy. The main goal of the study is classified into two categories. First, new detection model, i.e. D-Attention Unet, is developed by combining the context information of 3D medical data and CUS images. Second, the D-Attention Unet model was compared with other models to verify its usefulness for needle detection in continuous ultrasound images. The continuous needle images taken with ultrasonic waves were converted into still images for dataset to evaluate the performance of the D-Attention Unet. The dataset was used for training and testing. Based on the results, the proposed D-Attention Unet model showed the better performance than other 3 models (Unet, D-Unet and Attention Unet), with Dice Similarity Coefficient (DSC), Recall and Precision at 71.9%, 70.6% and 73.7%, respectively. In conclusion, the D-Attention Unet model provides accurate needle detection for US-guided biopsy or brachytherapy, facilitating the clinical workflow. Especially, this kind of research is enthusiastically being performed on how to add image processing techniques to learning techniques. Thus, the proposed method is applied in this manner, it will be more effective technique than before.

Effects of Therapeutic Ultrasound on Experimental Induced Rectal Sarcoma(CT-26) (실험적으로 유발된 직장종양에 대한 치료적 초음파의 효과)

  • Cheong, Mee-Sun;Oh, Myoung-Hwa;Kim, Gye-Yeop;Kim, Chan-Kyu
    • Journal of Korean Physical Therapy Science
    • /
    • v.11 no.3
    • /
    • pp.5-13
    • /
    • 2004
  • The use of therapeutic ultrasound(US) in humans with malignant neoplasms has been contra-indicated in physical therapy practice. Some studies have shown the results after application of US inhibited of tumor growth but some studies have shown the results facilitated of tumor growth in mouse. The purpose of this study were to determine the effects of US on rectal sarcoma(CT-26) in mouse and to determine the histological change of tumor. Thirty-five female BALB/C mouse, age 6 to 8 weeks received subcutaneous injection of 0.1 105 tumor cells. When tumors grew to 5 mm in diameters, the mouse were randomly assigned to control group(n=7) and high powered continuous US group(n=7) and low powered continuous US group(n=7) and high powered pulsed US group(n=7) and low powered pulsed US group(n=7). The experimental group (four groups) received 10 treatments over a 10-day period of 3 MHz ultrasound. Tumor dimension were measured on days 1(start of treatment), 5(midtreatment), and 10(end of treatment, preexcision and postexcision). Tumors were weighed after excision and the mouse were observated histological change of tumor. All tumors grew larger over time. Mean tumor weights(in grams) and volumes(in cubic millimeters) were 2.063 g and $2729.313\;mm^3$ for the high powered continuous US group 1.881 g and $2428.002\;mm^3$ for the low powered continuous US group 1.730 g and $2381.002\;mm^3$ for the high powered pulsed US 1.673 g and $2289.562\;mm^3$ for the low powered pulsed US group 1.670 g and $2297.333\;mm^3$ for the control group. Ultrasound increased the weight and volume of subcutaneous tumor in mouse. We urge caution in the use of ultrasound in the areas of tumors.

  • PDF

The Effect of Continuous Ultrasound Therapy and Pulsed Ultrasound Therapy on Adjuvant Induced Rheumatoid Arthritis in Rat (지속적인 초음파치료와 맥동 초음파치료가 Adjuvant로 유도된 흰쥐의 관절염에 미치는 효과)

  • Lee, Byeung-Ok;Min, Kyung-Ok;Hong, Wan-Seng;Lee, Kyung-Moo;Hwang, Seock-Yeon
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.4
    • /
    • pp.7-14
    • /
    • 2002
  • The drug therapy for rheumatoid arthritis must be maintained constantly or for the whole life but is apt to induce the adverse effects in gastrointestinal or renal system. Therefor, newer methods are paid attention to reduce adverse effects. The thirty-two rat female separated into seven groups depending on the therapy or Freund's adjuvant applied: Normal group(n=8) not received anything, Positive control group(n=8) only received adjuvant, USC group(n=8) received continuous US, USP group(n=8) received pulsed US. The physical and radiological findings by thermal and non-thermal effects of ultrasound were evaluated in groups with continuous mode at 1 MHz, $0.5\;W/cm^2$ for 6 minutes and with pulsed mode (duty cycle 1:9) at 1 MHz, $0.5\;W/cm^2$ for 6 minutes. The result summarized followings. 1. Swelling of forepaw and hindpaw was significantly reduced in USP. 2. Arthritis indices in USP group were significantly reduced than those in PCG. 3. In naked eye and radiologic findings, swelling was significantly prevented in USP group but not in PCG. The change of swelling, arthritis index, gross feature in naked eye, radiologic finding were significantly improved in all groups except for USC group, taking care for using its continuous mode.

  • PDF

An implementation of the continuous wave doppler system for blood flow measurement using the ultrasound (효율적인 혈류 속도 측정을 위한 연속 초음파 도플러 장치의 구현)

  • 박형재;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.516-519
    • /
    • 2001
  • To diagnose a patient's blood vessel disease, apoplexy, hypertension, arteriosclerosis, the blood velocity is very important. Determining the blood velocity methods using ultrasound are Continuous Doppler System and Pulse Doppler System. In using the Pulse Doppler System, we can obtain the position of blood velocity. But it is more complex hardware than Continuous Doppler System and it has low SNR(signal-noise ratio). So in this study, to obtain a believable information we use the Continuous Pulse Doppler System. Thus system have analog part and digital part. In analog part is composed of ultrasound generating part, the amplifying part to amplify the received signal from ultrasound sensor, the demodulation part to detect blood velocity and the filtering part to remove the noise. In digital part is composed of the A/D conversion part, digital signal processing part, and the communication part to communicate the PC. In this study to implement efficient ultrasound blood velocity measurement system, we can get the patient's blood velocity information in realtime. Thus, It is a useful in the accurate diagnosis with C.T(computered tomography), M.R.I(magnetic resonance imaging).

  • PDF

Transdermal Permeation Effects of Lidocaine HCl Gel Using Low Frequency Ultrasound of 500kHz (500KHz 초음파를 이용한 Lidocaine HCl Gel의 경피투과 효과)

  • Jeong, Dae-In;Yoon, Se-Won;Choi, Sug-Ju;Lee, Jeong-Woo;Kim, Myong-Hoon;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.1
    • /
    • pp.75-82
    • /
    • 2006
  • Purpose: This study conducted the following experiment to examine transdermal permeation effects or 500 KHz ultrasound with lidocaine HCl. Methods; First, to experiment skin permeation enhancement effects of 500 KHz ultrasound frequency, it produced apparatus and transducer of 500 KHz ultrasound and Franz diffusion cell for skim permenation experiment suitable to purposes of the experiment. Transdermal permeation experiment applied Lidocaine HCL gel to skin of hairless mouse depending on ultrasound frequency and duty cycle and analyzed permeation ratio with HPLC. Results: As a result of fixing lidocaine HCl gel at the same intensity with pulsed mode and continuous mode and comparing transdermal permeation ratio by frequency, transdermal permeation ratio was increased at 500 KHz ultrasound and remarkably increased at continuous ultrasound. It was found that 1 MHz and 500 KHz ultrasound in transdermal permeation experiment enhanced transdermal permeation of lidocaine HCl. In particular, transdermal permeation of 500 KHz using lidocaine HCl gel was highest. Conclusion: However, researches considering various frequencies, intensities and application hours in low frequency areas including 500 KHz ultrasound are needed to increase deep permeation or drugs.

  • PDF

The Effects of Blood Circulation and Skin Temperature by Ultrasound (초음파가 혈류량 및 피부온도에 미치는 영향)

  • Oh Min-Young;Jang Chel;Kim Hyun-jung
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.4
    • /
    • pp.179-201
    • /
    • 2004
  • The purpose of this study was to determine the effect of application methods in ultrasound on skin temperature and muscle blood flow. Thirty healthy volunteers without known vascular problems participated and randomly divided into three groups such as continuous wave group (CWG) which received a ultrasound treatment of continuous-wave, intermittent wave group (IWG) which received a ultrasound treatment of intermittent-wave at a dosage of $1.5\;W/cm^2$ for a duration of 5 minutes, and placebo group (PG) which received a ultrasound treatment of no-wave and no-dosage ultrasound to the anterior forearm. Blood flow and skin temperature was measured using MP 150 before and after ultrasound administration. The results were as follows : 1. Administration of ultrasound in all groups had increased effect on skeletal muscle blood flow immediately after treatment and for up to 10 minutes posttreatment. 2. CWG and IWG showed increased skin temperature immediately after a ultrasound administration and maintained to 10 minutes posttreatment. PG showed increased skin temperature immediately after a ultrasound administration but returned to initial state to 10 minutes posttreatment. 3. The great change on skeletal muscle blood flow among three groups showed in CWG ($6.27{\pm}1.72$) and then displayed in PG ($5.12{\pm}1.66$) and IWG ($4.61{\pm}2.19$) in order. 4. The vast change on skin temperature among three groups showed in CWG and then IWG and PG in order.

  • PDF

Effect of Low-Intensity Ultrasound on Bone Growth (저강도 초음파치료의 골절치유 효과)

  • Yi, Chung-Hwi;Kim, Jong-Man;Hwang, Tae-Sun
    • Physical Therapy Korea
    • /
    • v.5 no.3
    • /
    • pp.34-41
    • /
    • 1998
  • Noninvasive low intensity ultrasound has been shown to be an effective means of accelerating bone fracture repair in both animal and clinical studies. The effects of ultrasound stimulation on bone repair after fibular osteotomy were assessed in a rabbit fibular fracture model. Bilateral closed fibular fractures were made in skeletally mature male White Japanese rabbits. In this study, 24 subjects were randomly divided into 2 groups: experimental group 1 (n=12), and experimental group 2 (n=12). Experimental group 1 received 0.875 MHz continuous ultrasound and Experimental group 2 was treated with 3 MHz continuous u1trasound. The ultrasound intensity was 50 $mW/cm^2$ and treatment time was 10 minutes for every session in both groups. In each rabbit, one fibula served as a control and the other was subjected to ultrasound treatment 5 times per week for 3 weeks. After 3 weeks, rabbits were sacrificed and the ratios of the area between the trabeculae and bone marrow of the fibulae were calculated. At the end of the experimental period, 14 of the 24 rabbits were excluded due to complications from surgery or inadequate fracture status for this study. There was no statistically significant difference in the trabeculae area between experimental leg and control leg in experimental group 1 and experimental group 2 (p>0.05). And there was also no statistic-statistically significant difference between experimental group 1 and experimental group 2 according to ultrasound treatment frequencies, 0.875 MHz and 3 MHz (p>0.05). These data suggest that in Japanese white rabbits, low intensity ultrasound stimulation does not facilitate fracture repair nor is there any difference in fracture repair results between ultrasound frequencies, 0.875 MHz and 3 MHz.

  • PDF

Clinical Responses of Ultrasound on Adjuvant-Induced Arthritis in Rats (Adjuvant로 유발된 관절염의 흰 쥐에서 초음파의 임상반응)

  • Lee, Dong-Jin
    • Physical Therapy Korea
    • /
    • v.10 no.2
    • /
    • pp.45-59
    • /
    • 2003
  • The purpose of this study was to assess the effects of ultrasound on adjuvant-induced arthritis in rats. Adjuvant arthritis was induced in 26 female Sprauge-Dawley rats by the subcutaneous injection of a single dose of .1 mL of Complete Freund's Adjuvant (CFA) (1 mg of Mycobacterium Butyricum suspended in .1 $m{\ell}$ paraffin oil) into the right hind paw. After confirming inflammatory edema and arthritis in the paw 2 weeks later, the arthritic rats were divided into 3 groups, i.e., a control group, a pulsed ultrasound group (Group A), and a continuous ultrasound group (Group B) with 8 rats placed in each group. The rats in Group A were treated with pulsed ultrasound at 1 MHz frequency with .5 $W/cm^2$ intensity in 1 : 4 mode for 3 minutes. The rats in Group B were treated with continuous ultrasound at 1 MHz frequency with 2 $W/cm^2$ intensity in the continuous mode for 3 minutes. The ultrasound treatment was done in the left and right ankles for 2 weeks. Clinical, radiographic and histopathologic findings were then evaluated before and after treatment and yielded the following results. 1. No significant difference was present in body weight between the control group and the treated groups. 2. A statistically significant decrease in the edema of the paw was seen in the rats in Group A that was treated with pulsed ultrasound by 26~29 days after the treatment started (p<.05). 3. According to radiological examination, Group A showed the lowest score in arthritis scale which means it showed a tendency to suppress arthritic inflammation of the left and right hind paws. However, no statistically significant difference was present in the score between the control group, Group A and Group B. 4. According to histopathologic findings, the degree of infiltration by inflammatory cells and hypertrophy of the synovium were less in Group A compared with the control group and Group B. The results of the study show that rats that were treated with the pulsed ultrasound effectively suppressed adjuvant arthritis. However, more effort is needed to objectively prove the effectiveness of ultrasound by developing more sensitive testing methods that could quantitatively evaluate the treatment effects of acute rheumatoid arthritis and by trying out different ultrasound treatment methods.

  • PDF