• Title/Summary/Keyword: Control Points

Search Result 3,448, Processing Time 0.026 seconds

Research on Standardization for Survey Control Points (측량기준점 표준화 방안 연구)

  • Lee, Hyun Jik
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.79-88
    • /
    • 2015
  • In any production and construction of geospatial information covering surveying, survey control point is a vital geospatial information. Survey control points in South Korea are currently classified as following: national control points, public control points, and cadastral control points. Each of these different categories of survey control points act as a basis and sets perimeters for the production, management and operation of subjects within the category. Universal standard, the unified format between different survey control points, also, are not yet defined, causing difference in basic information provided by altering categories and disturbance in connecting, managing, utilizing and operating survey control points. Establishment of a standard regarding survey control points, is therefore required for the efficacy of their utilization. This study, to solve such inadequacies, selects management items for creation of standardized survey control point, by investigating domestically and internationally the status of operating survey control points, determining data model for management, establishing TTA and agency standards, and establishing of activation methodology for survey control point standards.

Infection control by type of dental institution (치과의료기관 유형별 감염관리 이행실태)

  • Lee, Ye-Rin;Han, Gyeong-Soon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.20 no.6
    • /
    • pp.875-888
    • /
    • 2020
  • Objectives: The purpose of this study was to investigate the infection control system and actual conditions according to the type of dental medical institution. Methods: From April 1st to May 10th, 2020, dental institutions were recruited through stratified random sampling. Each item constituting the infection control system by dental institution type was analyzed using the chi-square test and fisher's exact test. Results: The infection control system and operation level of each dental institution type was 89.0 points for university-general hospitals, 75.6 points for dental hospitals, and 34.4 points for dental clinics. The environment management levels were 76.1, 72.5, 73.0, and 74.0 points for university-general hospitals, similar to 77.2, 75.1, 71.0, and 73.8 points for dental hospitals, while dental clinics had 61.1, 40.0, 37.0, and 45.6 points. Prevention and management of staff infection exposure, wearing personal protective equipment, and hand hygiene levels were 90.7, 75.5, 88.5 points for university-general hospitals, 79.8, 79.5, 80.4 points for dental hospitals, and 50.2, 88.0, 61.5 points for dental clinics, respectively. Conclusions: Efforts are required to bring about improvement in the areas of insufficient infection control in order to raise the overall infection control levels, especially the management of dental clinics is urgently needed.

Studies on the HACCP Model of Steak-Set Menu in Hotel (HACCP 모델 적용시 호텔 .레스토랑의 세트 메뉴 중 스테이크에 관한 연구)

  • 양신철
    • Journal of Applied Tourism Food and Beverage Management and Research
    • /
    • v.12 no.1
    • /
    • pp.5-24
    • /
    • 2001
  • This study was focused on the sanitary analysis of hazard factors and the establishment of critical control points on steak-set menu In hotel by the documents and microbiological investigation. The hazard factors of shrimp cocktail were microbial contamination, residual pesticides, unsuitable healing and cross contamination. The hazard factors of potato soap were residual pesticides, microorganisms contamination, unsuitable heating and solanine in potato. The hazard factors of simple salad were microorganisms contamination, unsuitable heating and cross contamination by inappropriate package. The hazard factors of steal were residual antimicrobial drugs, microorganisms contamination, unsuitable heating and cross contamination. The critical control points of shrimp cocktail were temperature control , number of washing and center temperature control of heating step. The critical control points of potato soup were stock temperature control , number of washing and center temperature control of Heating step. The critical control points of simple salad were number of washing and dryness of utensil. The critical control points of steak were stock temperature control , number of washing, center temperature and time control of heating step.

  • PDF

Improvement of the Cadastral Control Points for an Establishment of the National Cadastral Reform Infrastructures (지적재조사 시행기반 조성을 위한 지적측량기준점체계 정비방안)

  • Kim, Soon-Tae
    • Journal of the Korean association of regional geographers
    • /
    • v.15 no.1
    • /
    • pp.161-178
    • /
    • 2009
  • The introduction of a world geodetic system for cadastral survey will be started the enactment of the law on survey, hydro-graphical examination and cadastre. However, the cadastral control points are not homogeneous and correspond with national control points because of various reasons. To cope with this problem, the 1,600 high accurate control points, which can be interlocked with national GPS control points, has selected from existing 20,000 cadastral control points. These selected control points were calculated as an accurate world geodetic system and it makes a homogeneous cadastral survey network. Through these measures, for the future carrying out national project, this study will be effectively contributed to establish the cadastral infrastructures for the Korea cadastral reform project.

  • PDF

Accuracy of Geocoding According to The Number of Control Points (기준점 개수에 따른 RADARSAT-1 영상의 기하보정 정확도)

  • 손홍규;송영선;방수남;박완용
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.303-308
    • /
    • 2004
  • The acquisition of many control points for SAR data processing is very difficult and time_consuming steps. For resolving the problem about control points, this paper describes satellite orbit refinement method using minimum control point. Accuracy of geocoding according to distribution and number of control points are analyzed and geocoded RADARSAT image was produced in the paper.

  • PDF

A study on the optimal tracking problems with predefined data by using iterative learning control

  • Le, Dang-Khanh;Le, Dang-Phuong;Nam, Taek-Kun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1303-1309
    • /
    • 2014
  • In this paper, we present an iterative learning control (ILC) framework for tracking problems with predefined data points that are desired points at certain time instants. To design ILC systems for such problems, a new ILC scheme is proposed to produce output curves that pass close to the desired points. Unlike traditional ILC approaches, an algorithm will be developed in which the control signals are generated by solving an optimal ILC problem with respect to the desired sampling points. In another word, it is a direct approach for the multiple points tracking ILC control problem where we do not need to divide the tracking problem into two steps separately as trajectory planning and ILC controller.The strength of the proposed formulation is the methodology to obtain a control signal through learning law only considering the given data points and dynamic system, instead of following the direction of tracking a prior identified trajectory. The key advantage of the proposed approach is to significantly reduce the computational cost. Finally, simulation results will be introduced to confirm the effectiveness of proposed scheme.

Determination of Planimetric Control Coordinates by Repetative Free Network Adjustments (반복자유망조정에 의한 평면기준점좌표의 결정)

  • Yeu, Bock-Mo;Kwon, Hyun;Pyo, Myung-Young
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.13 no.1
    • /
    • pp.107-113
    • /
    • 1995
  • Generally, the objectives of the geodetic network adjustments are for solving the configuration of geodetic net-works and the problem of observation plans. In this study, assuming that the configuration is fixed, for improving the accuracy of geodetic networks, we focus on choosing adjustment control points and adjustment methods. By choosing adjustment control points and adjustment methods, the adjustment result accuracy of national geodetic networks can be different. So, in this study, we introduce the algorithm that use free network adjustment concept to minimize the displacements of new station points but fixing existing control points. Then, us-ing adjustment results, we can check the errors of existing control points. After checking the errors of existing control point, in case of severe error points in existing control points, we change those points into unknown station points and repeat the algorithm to optimize the coordinates of new station points. As applying this algorithm to simulation network, we can check the errors of existing control points. And changing severe error points into unknown station points, we can decrease the errors of network and optimize the coordinates of new station points. From the results of simulation network adjustment, we think that, as applying this algorithms to sequential adjustment of geodetic network and public surveying that using national geodetic network, the accuracy of network adjustments can be improved.

  • PDF

A Study on Computation of Unified Coordinate of Cadastral Control Points over the Field with Different Surveying Origins (기타원점지역 지적측량기준점의 통일 좌표 산출 연구)

  • Yang, Chul-Soo;Jin, Jung-No
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.3
    • /
    • pp.3-13
    • /
    • 2008
  • The coordinate of cadastral control points located over the area of different surveying origins is computed in a single surveying origin by trilateration adjustment of GPS baseline measurements. In every different surveying origins, well-matched control points are selected and mutually coinciding coordinates are computed by free network adjustment. Then, the coordinate of the other control points over the area is computed by joining these points to the adjusted points. In practice, by using 18 points of Gari, 17 points of Gyeyang, and 33 points of Central origin in Incheon, the coordinates of total 68 points in every surveying origin are computed. Between the points of different surveying origins, it is found that there are quantitative differences in azimuth and scale factors and the approximate point coordinate of other surveying origins is calculated by correcting the scale and azimuth.

  • PDF

STUDY ABOUT THE SELECTION OF COMTROL AND INDICATION POINT FOR TOTAL AUTOMATION (전력설비종합자동화를 위한 감시제어포인트 선정에 관한 연구)

  • 이용해;남태현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.562-566
    • /
    • 1989
  • The selection of control and indication joints effects the supervisory and control scope of SCADA system. This paper proposes the point selection for the no-man substation. The points of no-man s/s are 3-4times as many ad points of man-substation. And also the considering points are described to implement total automation.

  • PDF

Sensitivity Analysis of Anti-resonance Frequency for Vibration Test Control of a Fixture

  • Jeong, Weui-Bong;Yoo, Wan-Suk;Kim, Jun-Yeop
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1732-1738
    • /
    • 2003
  • The test specimen in environmental vibration test is connected to the fixture through several attachment points. The forces generated by the shaker must be transmitted equally to all attachment points. The forces transmitted to attachment points, however, are different because of the flexural vibration of the fixture. The variations of the transmitted force cause the under-test, especially at anti-resonance frequencies, in vibration test control. Anti-resonance frequencies at the attachment points of the fixture must be same in order to avoid the under-test in vibration test control. The structural modification of the fixture is needed so that anti-resonance frequencies at attachment points have the same value. In this paper, the method to calculate the anti-resonance frequencies and those sensitivities is presented. This sensitivity analysis is applied to the structural modification of the fixture excited at multi-points by the shaker. The antiresonance frequencies at the attachment points of the fixture can have the same value after structural modification, and the under-test in the vibration test control can be removed. Several computer simulations show that the proposed method can remove the under-tests, which are not removed in conventional vibration test control.