• Title/Summary/Keyword: Corneal curvature

Search Result 24, Processing Time 0.031 seconds

Age and Sex Related Changes in Corneal Thickness and Anterior Corneal Curvature in Korean Young Population with Orbscan II Topography System

  • Lee, Dong-Hee;Kim, Douk-Hoon;Park, Seung-Hwan
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.68-73
    • /
    • 2011
  • This study investigated, using the Orbscan II topography system, the influence of age and sex related changes on the corneal thickness and anterior corneal curvature, more specifically the fine structure of the cornea, in a Korean young population. The Orbscan II topography system is a computer-assisted slit-beam scanning technology that can map the anterior section of the cornea. The mean central corneal thickness of all subjects was $547.532{\pm}44.529\;{\mu}m$. There was no statistical difference (p>0.5) in the mean central corneal thickness between males and females. Sex and age related changes in the mean central corneal thickness had no specific statistical difference (P>0.5). There was a negative correlation between the anterior corneal curvature and the central corneal thickness in all subjects, except for the twenty year olds. However, the thickness relationship between the mean central corneal and the eight paracentral corneal thicknesses had strong statistical differences in all subjects. Also age and sex related changes in the central corneal thickness and the anterior corneal curvature in all subjects had no statistically significant difference, except from 20-26 years old (p>0.05). This information could be a suitable reference basis for future studies in the young population of Asia and for the development of examination tools for corneal refractive surgery.

The Correlation Between Corneal Eccentricity and Radius Curvature by Fitting Status of Soft Contact Lens Wearer (소프트 콘택트렌즈 착용자의 피팅 상태에 따른 각막 이심률과 곡률반경과의 상관관계)

  • Han, Sun-Hee;Kim, Bong-hwan;Park, Jun-Sung;Baek, Su-won;Kwon, Sung Jin;Kim, Eun Kyoung;Yoon, Jung Na;Choi, So Min;Heo, A Jeong;Park, Eun Hye
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.662-670
    • /
    • 2016
  • Purpose. Because of a recent increase in use of soft contact lens at younger ages, in the present study, the correlation between corneal eccentricity and radius of curvature and fitting types of contact lens was investigated. Methods. The study evaluated the fitting status of targets through lens centration, push-up test, dynamic lag test and static lag test of lenses usually worn by 49 men and women (98eyes) in their 20s to 30s who put on soft contact lenses. After evaluation, the subjects were classified into 3 categories by fitting status(steep, aligment and flat). The radius of corneal curvature in the naked eyes was measured by using keratometer. Moreover the corneal eccentricity in the nasal side, temporal side, superior side and inferior side was measured by using the device capable of measuring the corneal eccentricity. Results. The radius of corneal curvature and corneal eccentricity of soft lenses worn by subjects were higher in the order of steep fitting and flat fitting, and the higher average corneal curvature radius and corneal eccentricity is intend to be more steep fitting(p=0.051, p=0.052). The corneal eccentricity showed a tendency to nasal fitting type at the higher eccentricity and temporal fitting type at the smaller eccentricity, statistically significant difference was observed(p<0.05). The study showed there were low correlation that nasal and temporal side at steep fitting, superior side at normal fitting and 4side(nasal, temporal, superior, inferior) at flat fitting, therefore when the corneal eccentricity changed the radius of corneal curvature also changed. The corneal eccentricity and the radius of corneal curvature showed statistically significant difference at 4side and each fitting types(p<0.05). Conclusions. The results of this study, the fitting status, of wearer are based on radius of corneal curvature and corneal eccentricity, and if lens fitting would be done considering that, it seems to be useful in a soft contact lens prescription.

Study in Radius of Corneal Curvature of university Students with Keratometer (RGP 렌즈 착용한 대학생의 각막곡률반경 측정)

  • Kim, Chang-Sik;Ryu, Kwang-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.181-185
    • /
    • 2006
  • The measurement of the radius of corneal curvature with keratometer was followed in 184 university students who wearing RGP contact lens and consisted of female(167), male(17) and keratoconus patients(3). Overall mean value in the radius of corneal curvature is 7.77mm, and right and left eyes is appeared the same mean value. Overall mean value in horizontal and vertical is 7.88mm and 7.65mm. Horizontal means is larger than vertical means by 0.22mm of the all female and male students. Male's mean value in the radius of corneal curvature(7.84mm) is larger than female's by 0.08mm, and right and left eyes is also the same mean value. Keratoconus patients' mean value in the radius of corneal curvature(6.86mm) is smaller than others students by 0.91mm.

  • PDF

Study on Distribution and Change of Curvature of the Anterior Corneal Surface with each Age in Emmetropia (정시안의 연령별 각막전면곡률 변화와 분포에 관한 연구)

  • Kim, Chan-Soo;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.211-221
    • /
    • 2004
  • The purpose of this study is to evaluate the distribution and change of curvature of the anterior corneal surface with age in emmetropia. 504 subjects who have emmetroia with good naked vision of at least 0.6-1.0 (spherical equivalent: +0.75D- -0.75D) participated in this study. The 504 subjects into 8 groups with 10 year interval from 3-year to 83-year, and their corneal curvatures were analyzed using manual keratometry. The results are as follows. In individual analysis: First, regression analysis of corneal curvature radius with age has given an equation: Y = -0.003x + 7.796 (r = -0.26). The average corneal curvature radii was measured to be $7.68{\pm}0.25mm$ at 38.3-year and range was 6.98-8.54 mm. Second, frequency of corneal curvature radius were obtained in 36% between 7.61 and 7.80 mm, 78% between 7.41 and 8.00 mm, 96% between 7.21 and 8.20 mm, 100% between 6.98 and 8.54 mm. Third, as for the comparison of corneal curvature radius with respect to sex, The mean value of male (n = 304, mean: 37.6-year $7.72{\pm}0.24mm$, Range: 7.09-8.54 mm) is larger than that of female (n = 200, mean: 39.3-year $7.62{\pm}0.24mm$, Range: 6.98-8.42 mm) by 0.1mm (p<0.01). In groups analysis: First, regression analysis of corneal curvature radius with age has given an equation: $Y=-0.0066x^2+0.0227x+7.7282$ (r = -0.90). Second, vertical and horizontal curvature radius decreased with age (p < 0.01). Especially the decrease of horizontal curvature radius were more pronounced than the decrease of vertical (horizontal:10-70 age group: 0.38 mm decrease, vertical:10-70 age group: 0.20 mm decrease). Third, difference between steep and flat meridian (astigmatism) progressively decreased with age. (low age group:0.18 mm difference, high age group: 0.08 mm difference). Fourth, the corneal curvature radius of male was larger than female's in total groups(p < 0.01). Consequently, the change of corneal curvature radius with age progressively decreased in all conditions (mean, vertical, horizontal, male, and female) and this change was more outstanding in horizontal rather than in vertical.

  • PDF

The Effect of Refractive and Corneal Recovery after Discontinuation of Orthokeratology Contact Lenses in Children (각막굴절교정렌즈 어린이 착용자에서 착용 중지 후 굴절력과 각막형상 복귀에 관한 연구)

  • Mun, Mi-Young;Lee, Koon-Ja;Lee, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: To investigate the corneal recovery after discontinuing orthokeratology (OK) lenses wear in children for long-term period. Methods: Among the OK lens wearers who wear over 8 months and showed successful refractive correction, 25 subjects were selected who want to discontinue the OK lenses. Uncorrected visual acuity, refractive correction, corneal curvature (Sim K), central corneal thickness and corneal eccentricity were measured during the OK lens wearing period and after discontinuation for 1 month. Results: Uncorrected visual acuity and corneal shape had remodeled significantly during the OK lens wear and recovered significantly during the first week of discontinuation. Uncorrected visual acuity and refractive correction had achieved full recovery 2 weeks after discontinuation of lens wear and were highly correlated with the changes in corneal thickness. But corneal shape recovered slowly, eccentricity had recovered fully after 1 month and corneal curvature and central thickness had not been achieved full recovery until 1 month after discontinuation. Conclusions: Recovery of after longterm use of OK lens is rapid for refractive change, but slow for corneal curvature and central thickness that to refit the contact lenses, practitioners need patience.

  • PDF

Mathematical Expression of the Toric Cornea using Corneal Topography Measurements (각막지형도(topography) 각막곡률로부터 토릭 각막형상의 수식화)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.439-444
    • /
    • 2011
  • Purpose: To represent the shape of toric corea in the elliptical function for the determination of curvature distribution and lacrimal thickness between cornea and contact lens when the lens is fitted. Methods: Topography measurements of corneal curvature and curvature equation derived from the assumed elliptical function were evaluated using the Excel program which included the necessary equation derived. Results: Mathematical expressions for the cornea whose ribbon shaped-topography image, in which the center does not coincide with the corneal apex, can be determined. Conclusions: For the application where the higher accuracy on the cornea is not required, such as higher order aberration, the cornea cal be expressed in the simple elliptical function.

Study of the cornea characteristics using Oculus Pentacam (Oculus Pentacam을 사용한 각막 특성 분석)

  • Lee, Jeung-Young;Park, Eun-Kyoo
    • Journal of the Korea society of information convergence
    • /
    • v.6 no.1
    • /
    • pp.37-41
    • /
    • 2013
  • In this study, by using the Oculus Pentacam, we analyzed the relationship of corneal front astigmatism corneal and the radius of curvature of the rear face of the 20's to 40's. The vertical radius of curvature were man 7.94mm (${\pm}0.22$), women 7.87mm (${\pm}0.21$), the horizontal radius of the anterior corneal appeared man 7.69mm (${\pm}0.27$), women 7.63mm(${\pm}0.23$). And rear vertical radius of curvature were man 6.52mm(${\pm}0.23$), woman 6.55mm (${\pm}0.22$), the horizontal radius of the anterior corneal appeared man 6.06mm (${\pm}0.24$), woman 6.08mm(${\pm}0.24$). The results of correlation analysis between the radius of corneal posterior surface and the anterior corneal surface, it was found out that there is a significant correlation. In this study, similar results were obtained anterior surface of the cornea, the radius of curvature of the rear surface, the refractive power, and astigmatism, as other papers that have been reported. But in this paper, the cornea thickness was thicker than other previously reported paper.

  • PDF

Scotopic Pupil Size in Myopes (근시안에서 암순응상태의 동공크기)

  • Jeong, Woo-Jae;Jeon, In-Chul;Kang, Ji-Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.197-202
    • /
    • 2013
  • Purpose: This research was performed to measure and analyze scotopic pupil size in myopes and to figure out the factors that influence it. Methods: The pupil size of 191 healthy myopic subjects were measured with the pupillometer (Colvard pupillometer, OASIS medical, USA) in scotopic and analyzed with the age, corneal size, spherical equivalent refractive error, corneal curvature. In addition, it was compared with the measurements of intra-examiner and inter-examiner to verify reproducibility of pupillometer. Results: The mean (${\pm}$SD) scotopic pupil size was $6.64{\pm}0.68$ mm (range, 5.00~8.00 mm), the lower age and the larger corneal size, The bigger the pupil size. The lower spherical equivalent refractive error and steepper corneal curvature tends to be smaller. The reproducibility of intra-examiner and inter-examiner in pupillometer showed the reliability highly (Guttman splithalf point > 0.91). Conclusions: The pupil size associated with age, corneal size, spherical equivalent refractive error and corneal curvature in scotopic condition. It can refer to prevent inconvenience that may occur RGP contact lenses, cataract surgery and refractive surgery.

Validating a New Approach to Quantify Posterior Corneal Curvature in Vivo (각막 후면 지형 측정을 위한 새로운 방법의 신뢰도 분석 및 평가)

  • Yoon, Jeong Ho;Avudainayagam, Kodikullam;Avudainayagam, Chitralekha;Swarbrick, Helen A.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.223-232
    • /
    • 2012
  • Purpose: Validating a new research method to determine posterior corneal curvature and asphericity(Q) in vivo, based on measurements of anterior corneal topography and corneal thickness. Methods: Anterior corneal topographic data, derived from the Medmont E300 corneal topographer, and total corneal thickness data measured along the horizontal corneal meridian using the Holden-Payor optical pachometer, were used to calculate the anterior and posterior corneal apical radii of curvature and Q. To calculate accurate total corneal thickness the local radius of anterior corneal curvature, and an exact solution for the relationship between real and apparent thickness were taken into consideration. This method differs from previous approach. An elliptical curve for anterior and posterior cornea were calculated by using best fit algorism of the anterior corneal topographic data and derived coordinates of the posterior cornea respectively. For validation of the calculations of the posterior corneal topography, ten polymethyl methacrylate (PMMA) lenses and right eyes of five adult subjects were examined. Results: The mean absolute accuracy (${\pm}$standard deviation(SD)) of calculated posterior apical radius and Q of ten PMMA lenses was $0.053{\pm}0.044mm$ (95% confidence interval (CI) -0.033 to 0.139), and $0.10{\pm}0.10$ (95% CI -0.10 to 0.31) respectively. The mean absolute repeatability coefficient (${\pm}SD$) of the calculated posterior apical radius and Q of five human eyes was $0.07{\pm}0.06mm$ (95% CI -0.05 to 0.19) and $0.09{\pm}0.07$ (95% CI -0.05 to 0.23), respectively. Conclusions: The result shows that acceptable accuracy in calculations of posterior apical radius and Q was achieved. This new method shows promise for application to the living human cornea.

The differences of tear film for young Korean of a day indoor space (실내 공간 내에서 한국인 청년의 하루 중 눈물층 변화)

  • Oh, Hyun Jin;Lee, Ji-Young
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.535-540
    • /
    • 2012
  • This study is to research the differences of tear film for young people in of a day in a restricted indoor space. The subjects are 58 eyes volunteers for twice preliminary inspection and tear test of a day. 58 healthy individuals with no eye disease, no body disease, orthophoria, corrective visual acuity more than 0.8, binocular spherical equivalence difference over 0.50 diopter, the flattest corneal curvature in horizontal meridian and the steepest corneal curvature in vertical meridian were tested. The uncorrective visual acuity, refractive error, corneal curvature, schirmer test and tear break up test were performed in the morning and afternoon. Schirmer test were $16.0{\pm}7.0mm$ in the morning and $14.1{\pm}7.1mm$ in the afternoon. TBUT were $11.3{\pm}0.6$ sec in the morning and $12.1{\pm}0.9$ sec in the afternoon. They have no significant differences.