• Title/Summary/Keyword: Counts Rate

Search Result 495, Processing Time 0.03 seconds

Acoustic emission behavior during fatigue crack propagation in 304 Stainless steel (피로균열진전에 따른 304 강의 음향방출 거동)

  • Oh, Kwang-Hwan;Jung, Chang-Kyu;Yang, Yoo-Chang;Han, Kyung-Seop
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.213-219
    • /
    • 2003
  • Acoustic emission behavior during fatigue crack growth test was investigated under various loading condition. To describe the acoustic emission activity, counts rate (d/dn) was related with SIFR (stress intensity factor range, K). Results indicated that SIFR could be divided into two parts according to its relationship with counts rate. For $K<25_{MPa\sqrt{m}}$, counts rate was increased as the SIFR increased. However, for values greater than $25_{MPa\sqrt{m}}$ , decreasing behavior was shown. This behavior of counts rate corresponding SIFR was keeping the same trend regardless of load range or crack length. Acoustic emission response to the single overload was sudden drop and slow recovery in counts rate like crack growth retardation. Under variable loading condition, counts rate of each loading block was same as that of constant amplitude loading. Overall experimental data was somewhat scattered since sensitive characteristics of acoustic emission method. However, these empirical relations indicated that counts rate was uniquely correlate with single parameter, SIFR.

  • PDF

Relationship between Fatigue Crack Growth Rate and Total Acoustic Emission Counts per Cycle (피로균열 성장률과 싸이클당 AE수 증가율간의 상호관계)

  • Kang-Yong,Lee;Hyung-Kyu,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.23 no.3
    • /
    • pp.17-26
    • /
    • 1986
  • A new relationship between total acoustic emission counts per cycle and crack growth rate is derived in terms of stress intensity factor to explain the acoustic emission behavior due to fatigue crack growth. The experimental results of the total acoustic emission counts per cycle obtained from aluminium 5,000 series alloy specimens are compared with the theoretical values. Both experimental and theoretical total acoustic emission counts per cycle result in the linear relationship to the crack length.

  • PDF

Evaluation of Grade of WA-Vitrified and Resinoid Bond Grinding Wheels by Acoustic Emission (AE에 의한 WA계 비트리파이드 및 레지노이드 결합제 연삭숫돌의 결합도 평가)

  • Joung, In-Kuen;Lim, Young-Ho;Kwon, Dong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.9
    • /
    • pp.74-85
    • /
    • 1995
  • The purpose of this paper is to evaluate the grade of WA vitrified and resinoid bond grinding wheels by the sue of AE measuring system. When the manufactured 48 kinds of specimens were scratched by the method of OKOSHI'S grade test, the relationship between the amount of bit scratch depth of grinding wheel specimens and the character- istics of AE signals, and the relationship of AE counts and grade were considered as fololws; (1) The higher the grades are AE cumlulative event counts N and AE event count rate n, the smaller the values tend to be. But A $E_{rms}$is in reverse. (2) In the case of same grade, the smaller the grain size is, the higher the value of AE cumulative event counts N and A $E_{rms}$is results of comparison and observation. The grinding wheel with lower elasticity and with higher percentage of pore detected higher value of AE cumula- tive event counts N than with higher elasticity and lower percentage of pore. But A $E_{rms}$ is in reverse. (3) AE cumulative event counts N and bit scratch depth h have normally one to one correspondence. (4) It can be expected that quantitative evaluations of grade by using AE have been carried out by the wave observation of AE signal in line with the relationship between load speed of bit and AE cumulative event counts N & AE event count rate n.' AE event count rate n.ate n.

  • PDF

A Study of Counting Efficiency according to the Window-width on Radionuclides $^{131}I\;and\;^{198}Au$ (방사성핵종(放射性核種) $^{131}I$$^{198}Au$에서 Window 폭(幅)에 따른 계수측정(計數測定)에 관(關)한 연구(硏究))

  • Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.85-92
    • /
    • 1984
  • It is a esperimental report to investigation for optimum window-width on radionuclides $^{131}I\;and\;^{198}Au$ The obtained results were as follow; 1. In case of $^{131}I$, 1) The lowest counts produced at the window-width of 10KeV and 20KeV. 2) The count rate, more increased, when the window-width more opened, but the counting efficiency is very good between 70KeV and 130KeV window-width (19.23% -35.71% about the peak energy). 3) The heighest counting rate per KeV of window appeared at 130KeV window-width. 4) BKG counts increased proportionally to the wider window as 5.473 + 0.016 cpm. 2. In case of $^{198}Au$ 1) The lowest counts appeared at 10KeV and 20KeV window. 2) Count rate more increased, when window-width more opened, but the counting efficiency is very good between 80KeV and 140KeV window (19.46% - 34.06% about the peak energy). 3) The highest counting rate per KeV of the window appeared at 140KeV window. 4) BKG counts increased proportionally to the wider window-width as 4.74 + 1.09 cpm.

  • PDF

부화장 위생검사

  • Kim, Jin-Hyeon;Ha, Jong-Su;Seon, Jeong-Won;Yun, Mi-Yeong;Kim, Gi-Seok
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2006.11a
    • /
    • pp.86-87
    • /
    • 2006
  • The hatchery sanitation has a significant impact on chick quality. This study was carried out to investigate the bacterial contamination in the broiler hatchery. The aerosol bacterial contamination was low except for the operating hatcher that the bacterial counts were measured almost over 300 counts/64cm$^{2}$. The bacterial contamination of the facilities and equipments had a similar tendency as compared with the aerosol bacterial contamination. More than six groups of the Salmonella species were isolated almost from the hatcher and the related facilities and equipments. Also, in this study, we compared the effects of four methods of 37% formalin adminstration in hatcher. At hatch, the aerosol bacterial counts in hatcher receiving 37% formalin as constant rate infusion method during hatching were significantly lower than in each hatcher receiving 37% formalin once at transfer and not receiving 37% formalin, respectively(p<0.05).

  • PDF

Intrusion Detection System for In-Vehicle Network to Improve Detection Performance Considering Attack Counts and Attack Types (공격 횟수와 공격 유형을 고려하여 탐지 성능을 개선한 차량 내 네트워크의 침입 탐지 시스템)

  • Hyunchul, Im;Donghyeon, Lee;Seongsoo, Lee
    • Journal of IKEEE
    • /
    • v.26 no.4
    • /
    • pp.622-627
    • /
    • 2022
  • This paper proposes an intrusion detection system for in-vehicle network to improve detection performance considering attack counts and attack types. In intrusion detection system, both FNR (False Negative Rate), where intrusion frame is misjudged as normal frame, and FPR (False Positive Rate), where normal frame is misjudged as intrusion frame, seriously affect vechicle safety. This paper proposes a novel intrusion detection algorithm to improve both FNR and FPR, where data frame previously detected as intrusion above certain attack counts is automatically detected as intrusion and the automatic intrusion detection method is adaptively applied according to attack types. From the simulation results, the propsoed method effectively improve both FNR and FPR in DoS(Denial of Service) attack and spoofing attack.

The clinical study on the chronic prostatitis patient (만성 전립선염 환자에 대한 임상적 고찰)

  • Cho, Chung-Sik;Kim, Chul-Jung;Lim, Bum-Soo
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.4
    • /
    • pp.519-525
    • /
    • 2001
  • Objectives : In order to study the effect of oriental medical therapy on chronic prostatitis patient, the change of WBC counts on expressed prostatic secretion(EPS) was investigated. Methods : Chronic prostatitis patient who had been diagnosed by EPS test was re-tested as same way after improvement of symptom And then we investigated the change of WBC counts on EPS according to therapeutic period, age, usual habit, herb medicine and symptom of each patient, and his and his sexual partner's past history of STD or UTI. Results : According to the change of WBC counts on EPS, improvement rate was 83.3%, cure rate was 46.7%. The youth who didn't have the usual habit of enduring ejaculation during sexual intercourse, enduring urination and sitting long time a day was improved well. Conclusions : According to the above results, it is suggested that oriental medical therapy is effective to the change of WBC counts on EPS.

  • PDF

Analysis of Factors Influencing Patent Citations (특허 인용에 영향을 미치는 요인 분석)

  • Yoo, Jae-Bok;Chung, Young-Mee
    • Journal of the Korean Society for information Management
    • /
    • v.27 no.1
    • /
    • pp.103-118
    • /
    • 2010
  • Recently, the valuation of patented technology has been greatly emphasized, and patent citation has been accepted as a very useful index of this technology. In this study, we performed correlation analyses between the patent citation counts and 17 explanatory variables of morphological, technological, and conceptual factors with a test dataset of U.S. patents in five subject fields. Seven variables having 5% or more standardized variances($r^2$) with patent citation counts were identified; number of pages, number of claims, reference-average-citation rate, patent increase/decrease rate, strength of bibliographic coupling, co-citation counts and document similarity. The result of the ANOVA test shows that the mean values of these variables vary among most subject fields.

Survey on Bacteriological Contamination of Restaurants in Seoul Area (서울지역 대중음식점의 위생상태에 관한 미생물학적 조사연구 - 물수건, 냉면육수, 엽차를 중심으로 -)

  • Shin Jung Sik;Park Sang Huun
    • Journal of environmental and Sanitary engineering
    • /
    • v.1 no.1 s.1
    • /
    • pp.41-46
    • /
    • 1986
  • This study was performed to investigate the sanitation of restaurants in Seoul Area. The subjects were 153 wet towels, 64 cold noodle soup and 190 barely tea. The results were as follows: In wet towels: The detected rate of standard plate counts was $86.9\%$ (133 samples) and average count was $1.8\times10^3/g$ $the detected rate of coliform was $37.9\%$ (58 samples) and average count by MPN method was $2.0\times10^3/100g$, the detected rate of fecal coliform was $15.7\%$ (24 samples) and average count by MPN method was $3.2\times10/100g$. In cold noodle soups: The detected rate of standard plate counts was $100\%$ (64 samples) and average count was $9.4\times10^5/ml$, the detected rate of coliform was $75\%$ (48 samples) and average count by MPN method was $6.0\times10^5/100ml$, the detected rate of fecal coliform was $51.6\%$ (33 samples) and average count by MPN method was $3.4\times10^3/100ml$. In barely tea: The detected rate of standard plate counts was $87.4\%$(166 samples) and average count was $5.8\times10^3/ml$the detected rate of coliform was $66.3\%$ (126 samples) and average count by MPN method was $3.9\times10^3/100ml$, the detected rate of fecal coliform was $32.6\%$ (62 samples) and average count was by MPN method was $4.7\times10/100ml$.

  • PDF

Detection of Pulsed Photostimulated Luminescence Signals Emitted by Infrared Stimulation of Irradiated Spices during Storage under Two Conditions

  • Yi, Sang-Duk;Woo, Si-Ho;Yang, Jae-Seung
    • Preventive Nutrition and Food Science
    • /
    • v.6 no.3
    • /
    • pp.152-157
    • /
    • 2001
  • Accumulated photon counts in immediate measurement after irradiation of marjoram, basil and thyme were shown to be below 625$\pm$162, 577$\pm$178 and 1261$\pm$640 Pc, respectively. The accumulated photon counts increased linearly with increasing irradiation doses up to 5 kGy and slightly increased from 5 kGy to 10 kGy. This trend was similar after storage periods. According to storage conditions, the difference of the accumulated photon counts was net clearly observed. The accumulated photon counts of irradiated spice samples decreased with increasing storage periods. The rate of decrease was higher in 5 and 10 kGy irradiated samples than that in 1 kGy, and in room conditions than that in darkroom conditions. The photon counts of the irradiated spice samples measured for 120 s were higher than those measured for 60 s. The irradiated spice samples showed higher photon counts than those of unirradiated samples in both room and darkroom conditions during all the storage periods. These results indicate that detection of irradiation was still possible after 24 weeks, although the PPSL signal of all spice samples decreased with increasing storage times.

  • PDF