• Title/Summary/Keyword: Current limitation effect

Search Result 100, Processing Time 0.028 seconds

The Effect of Gap Size on Counter Current Flow Limitation Phenomena in Narrow Annular Gaps with Large Diameter

  • Jeong, Ji-Hwan;Lee, Seung-Jin;Park, Rae-Joon;Kim, Sang-Baek
    • Nuclear Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.396-405
    • /
    • 2002
  • An experimental study on counter-current flow limitation phenomena in narrow annular passages was carried out The gap sizes tested were 1, 2 and 3 mm. This is very small compared with the outer diameter of the annular passage, 500 mm. It was visually observed that a CCFL might occur in some part of the periphery while the other part is remained in a counter current flow pattern. That is, non-uniform behaviour of fluids due 4o a 2-dimensional effect appear in a large diameter facility. Because of this non-uniformity, a CCFL is defined in the present work as the situation where net water accumulation is sustained. That is, some amount of water should not be allowed to penetrate the gap and accumulate over the gap at CCFL criterion. The measured data are presented in the form of Wallis'type correlation with characteristic length of gap size. It was found that the present correlation is in good agreement with other empirical correlation based on measurements whose test section diameter is close and the gap size is much larger than that of the present test section.

Analysis of effects of OCR in operation mode during fault ocuurs in Distribution System (배전계통 내 고장발생시 운전모드가 과전류계전기에 미치는 영향 분석)

  • Kim, Yong-Hwan;Rhee, Sang-Bong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.563-564
    • /
    • 2015
  • Recently, distributed generation using renewable energy resources have increased due to the limitation of conventional energy. To utilize these energy source effectively, a method of applying the energy storage system(ESS) in distribution system has been considered. In this paper, we simulated the one line-to-ground fault in power system with ESS. Based on these simulations, we analyzed the effect on Over Current Relay(OCR) operation. As a result, ESS operation modes result fault current fluctuation. Thus, OCR need to reset the pick up current. This paper analyze effect of ESS in distribution system according to OCR setting by using ElectroMagnetic Transient Program(EMTP).

  • PDF

Hydrodynamically Optimal Blade Design for 500kW Class Horizontal Axis Tidal Current Turbine (500kW급 수평축 조류발전기의 수력 최적 설계)

  • Ryu, Ki-Wahn
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.73-80
    • /
    • 2009
  • A tidal current turbine is designed and analyzed numerically by using blade element momentum theory. The rated power has a limitation because the diameter of the tidal current turbine cannot exceed the depth of sea water. This study investigates a horizontal axis tidal-current turbine with a rated power of 500 kW. NACA-6 series laminar foil shape is used for basic airfoil along the blade span. The distributions of chord length and twist angle along the blade span are obtained from the hydrodynamic optimization procedure. Prandtl's tip loss correction and angle of attack correction considering the three-dimensional effect are applied for this study. The power coefficient curve shows maximum peak at the rated tip speed ratio of 6.0, and the maximum torque coefficient is developed at the tip speed ratio of 4. The drag coefficient reaches about 0.85 at the design tip speed ratio.

Effect of Five Star Hotel Restaurant Cook's Emotional labor on Job Satisfaction and Customer Orientation

  • KIM, Hey-Sook
    • East Asian Journal of Business Economics (EAJBE)
    • /
    • v.8 no.2
    • /
    • pp.1-14
    • /
    • 2020
  • Purpose - The current study analyzes effects of hotel restaurant cook's emotional labor on job satisfaction and customer orientation. Research design and methodology - In order to achieve the current study's goal, sample was extracted targeting cooks working in 5-stars hotels located in Seoul considering spatial and time limitation. Method of research was direct research method with survey. Survey was conducted from April 1st, 2018 to April 20, 2018 (approximately 20 days). Total of 300 surveys were distributed to cooks working in 5-stars hotels located in Seoul, and among those 250 surveys were returned. Among returned 250 surveys, 246 surveys. Results - First, in order to test H1, effect of hotel restaurant cook's emotional labor on job satisfaction (satisfaction on superior and coworker) was analyzed. Second, in order to test H2, effect on hotel restaurant cook's emotional labor on job satisfaction (satisfaction on compensation and promotion) was analyzed. Third, satisfaction on superior and coworker had statistically significantly positive effect on customer orientation, while satisfaction on compensation and promotion did not have statistically significant effect. Conclusions - First, deep acting had statistically significantly positive effect on job satisfaction (satisfaction on superior and coworker), while surface acting did not have statistically significant effect. Second, both deep and surface acting had statistically significantly positive effect on job satisfaction (satisfaction on compensation and promotion). Third, satisfaction on superior and coworker had statistically significantly positive effect on customer orientation, while satisfaction on compensation and promotion did not have statistically significant effect.

Current-voltage Characteristics of Ceramics with Positive Temperature Coefficient of Resistance

  • Li, Yong-Gen;Cho, Sung-Gurl
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.10
    • /
    • pp.921-924
    • /
    • 2003
  • A current-voltage relation for Positive Temperature Coefficient of Resistance (PTCR) ceramic was derived and compared with the experimental data. The new current-voltage relation was developed based on Heywangs double Schottky barrier model and a bias distribution across the grain boundary. The voltage limitation V < 4${\Phi}$$\sub$b/ suggested by Heywang is no longer necessary in the new expression for the voltage dependence of the resistance. The pulsed voltages were applied to the PTCR ceramic specimen in order to avoid possible temperature variation during the measurement.

Trends of Sensor-based Intelligent Arc Welding Robot System (센서기반 지능형 아크 용접 로봇 시스템의 동향)

  • Joung, Ji Hoon;Shin, Hyeon-Ho;Song, Young Hoon;Kim, SooJong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.10
    • /
    • pp.1051-1056
    • /
    • 2014
  • In this paper, we introduce an intelligent robotic arc welding system which exploits sensors like as LVS (Laser Vision Sensor), Hall effect sensor, voltmeter and so on. The use of industrial robot is saturated because of its own limitation, and one of the major limitations is that industrial robot cannot recognize the environment. Lately, sensor-based environmental awareness research of the industrial robot is performed actively to overcome such limitation, and it can expand application field and improve productivity. We classify the sensor-based intelligent arc welding robot system by the goal and the sensing data. The goals can be categorized into detection of a welding start point, tracking of a welding line and correction of a torch deformation. The Sensing data can be categorized into welding data (i.e. current, voltage and short circuit detection) and displacement data (i.e. distance, position). This paper covers not only the explanation of the each category but also its advantage and limitation.

A Study on Stability Criterion for Cryocooler Operating HTS Coils (냉동기운전 고온초전도코일의 안전성평가기준에 관한 연구)

  • Ishiyama, Atsushi;Kim, Seok-Beom;Han, Kyung-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.317-323
    • /
    • 2001
  • We investigated the stability of cryocooler-cooled high-temperature superconducting (HTS) coils by using a computer program based on FEM. In this study, the current at which "thermal runaway" occurs, which depends on the relationship between the cooling power of the cryocooler and the heat generation in HTS coils, was adopted as a stability criterion of cryocooler operating HTS coils. It was shown that cryocooler-cooled HTS coil was stable in operating current above the critical current from the numerical analysis results by HTS model coil. And also, if we efficiently remove the heat generation from HTS coils by potimizing heat drain, the ramp-rate limitation can be mitigated because the effect of AC loss by the current rise was too small. Furthermore, in the case of pulsed operation; the HTS model coil is ramped from zero to the peak value in one second and back to zero current in one second, such as the operation of SMES device, the peak value of poerating current is 1.5-2 times greater than that of the thermal runaway current.

  • PDF

A Study on Estimation of Interrupting capability on Molded Case Circuit Breaker including Current Limiting Unit (2중 한류 구조를 갖는 배선용 차단기의 차단성능 평가 연구)

  • Kim, Yong-Gi;Song, Jung-Chun;Seo, Jung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.144-146
    • /
    • 2002
  • The latest development flow of MCCB(Molded Case Circuit Breaker) is largely separated from which are high capability of interrupting compact of size and multi-ability in functions. As follow of development of industrial system. MCCB which are including communication function and having a ultimate interrupting capability is required in electrical system. to attain an effective limitation of the peak let-through current and the let-through energy, the arc has to move rapidly off the contacts and has to increase the arc voltage which mainly effect to interrupt. In this paper. we made high performance circuit breaker which including current limiting unit which is attached to the main which is simulated by CAE tool that are repulsion force and mechanical dynamics after that we tested and finally selected optimized for circuit breaker.

  • PDF

Marketing Stimulating Factors of Impulsive Buying : Focus on TV Home Shopping Consumer (충동구매에 미치는 마케팅자극요인: TV홈쇼핑 이용자를 중심으로)

  • Kim, Chang-Ho
    • The Journal of Information Technology
    • /
    • v.8 no.4
    • /
    • pp.65-74
    • /
    • 2005
  • The central purpose of this paper is to examine impulsive buying from home shopping channels and to investigate some stimulating factors of marketing on the customers' impulsive buying. on TV. Survey questionnaires were given to 303 customers who have purchased products through TV home shopping more than once. We report the following findings. First, we find that product stimuli factors exert an effect on impulsive buying of fashion goods, but not of specialty goods. Second, of the two promotion stimuli factors a bonus pack and an extended payment period-the latter is shown to have a great effect. Third, in the case of price stimuli factors, concrete stimuli such as a discount range have a greater influence than abstract stimuli such as a reliable pricing. Finally, in the area of situational stimuli factors, speeches of show hosts have a bigger impact than buying situations such as limit selling. We believe that the current research provides a significant result, theoretically and practically, with respect to customers' behavior in TV home shopping. The methodological limitation involving samples and sampling method and the regional limitation make it difficult to generalize the findings. It should be worthy classifying and managing marketing stimuli. More practical research is in order.

  • PDF

Development and Application of Failure-Based Learning Conceptual Model for Construction Education

  • Lee, Do-Yeop;Yoon, Cheol-Hwan;Park, Chan-Sik
    • Journal of Construction Engineering and Project Management
    • /
    • v.1 no.2
    • /
    • pp.11-17
    • /
    • 2011
  • Recent demands from construction industry have emphasized the capability for graduates to have improved skills both technical and non-technical such as problem solving, interpersonal communication. To satisfy these demands, problem-based learning that is an instructional method characterized by the use of real world problem has been adopted and has proven its effectiveness various disciplines. However, in spite of the importance of field senses and dealing with real problem, construction engineering education has generally focused on traditional lecture-oriented course. In order to improve limitations of current construction education and to satisfy recent demands from construction industry, this paper proposes a new educational approach that is Failure-Based Learning for using combination of the procedural characteristics of the problem-based learning theory in construction technology education utilizing failure information that has the educational value in the construction area by reinterpreting characteristics of construction industry and construction failure information. The major results of this study are summarized as follows. 1) Educational effect of problem-based learning methodology and limitation of application in construction area 2) The educational value of the information on construction failure and limitation in application of the information in construction sector 3) Anticipated effect from application of the failure-based learning 4) Development and application of the failure-based learning conceptual model.