• Title/Summary/Keyword: Current source

Search Result 3,987, Processing Time 0.039 seconds

EEG Current Source Imaging using VEP Data Recorded inside a 3.0T MRI Magnet

  • Han Jae Y.;Choi Young H.;Im Chang H.;Kim Tae-S.;Lee Soo Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.95-99
    • /
    • 2005
  • We have performed EEG current source imaging on the cortical surface using visual evoked potentials (VEPs) recorded inside a 3.0 T MRI magnet. In order to remove ballistocardiogram (BCG) artifacts in the VEPs, an improved BCG template subtraction technique is devised. Using the cortically constrained current source imaging technique and pattern-reversal visual stimulations, we have obtained current source maps from 10 subjects. To validate the EEG current source imaging inside the magnet, we have compared the current source maps to the ones obtained outside the magnet. The experimental results demonstrate that there is a strong correspondence between the current source maps, proving that current source imaging is feasible with the evoked potentials recorded inside a 3.0 T MRI magnet.

Finite Element Analysis of the Eddy Currents Inside the Source Conductors (전류원 도체 내의 와전류 현상의 2차원 유한 요소 해석)

  • Kim, Hong-Kyu;Jung, Hyun-Kyo;Sim, Dong-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.22-24
    • /
    • 1998
  • The current distribution in the source coil region is analyzed using the two dimensional finite element method. The variables in the FEM are the magnetic vector potentials and the source current density. The boundary condition for the source current density is that the total current is the sum of the eddy current and the source current and is known quantity from measurement. The simulation results are compared with the analytical solution. It is found that the method can analyze the current distribution in the source conductors very accurately.

  • PDF

Commutation Performance of Current Source Converters fed Switched Reluctance Motors (스위치드 리럭턴스 전동기 구동 전류형 컨버터의 전류특성)

  • Jang, Do-Hyun;Choe, ㅍ;Kim, Ki-Su;Jeong, Seon-Ung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.38-46
    • /
    • 1996
  • The commutation operation of the current source converter for switched reluctance motor drives is analyzed in this paper. The commutation operation in the current source converter consists of two modes. At turn-off of phase switch, the phase current decreases sinusoidally, and the sum of two phase currents during commutation period is constant. At this time, the capacitor voltage increases quickly with changing polarity and decreases slowly when another phase switches turn on or off. Frequency of step-down DC chopper in the current source converter is low because of the dump such as BJTs and GTOs are possible as phase switches instead of Power MOSFET and IGBTS. They may result in reductions of conduction losses and manufacturing cost in the current source converter comparing to the voltage source converter of SRM.

  • PDF

A Study on Source Current Control of Voltage Source PWM Converter based on Lossless Resonator (무손실 공진기를 가지는 전압형 PWM 컨버터의 전원전류 제어에 관한 연구)

  • Heo, T.W.;Shin, D.W.;Kim, G.H.;Jin, H.J.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2040-2042
    • /
    • 1997
  • A voltage source PWM converter based on lossless resonator and a source current control system are proposed in this paper. It is proved that steady-state deviation reduces to zero from the transfer function of source current control system, owing to the lossless resonator. The system can be controlled by the feedback control only, because of no need to use a feedforward control in the proposed a source current control system. Therefore, as using lossless resonator, control system can be simply made up. Simulations are described in the case of difference between source current and source current reference.

  • PDF

Study on the Heat Generation Characteristics of the Carbon Heating Source with High Temperature (고온 카본발열체의 발열특성에 관한 연구)

  • Bae, K.Y.;Lee, K.S.;Shin, J.H.;Jeong, H.M.;Chung, H.S.;Chun, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.106-111
    • /
    • 2001
  • This paper is a study on the heat generation characteristics of the carbon heating source with high temperature. The main variables of this study are the input current and the amount of carbon heating source. As the results of the experiment in the waste rate of carbon heating source. The case of carbon heating source 300g was large than 500g. As the input current and the temperature are increased, the resistance values of carbon heating source were large. The Joule heat was represented the large value as the amount of heating source decrease with the input current. Finally, the heating source was represented the electrical steady state as the input current is increase.

  • PDF

A Fault Location Algorithm Using Adaptively Estimated Local Source Impedance for a Double-Circuit Transmission Line System (자기단 전원 임피던스 추정 기법을 사용한 병행 2회선 송전선로 고장점 표정 알고리즘)

  • Park, Gun-Ho;Kang, Sang-Hee;Kim, Sok-Il;Shin, Jonathan H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.373-379
    • /
    • 2012
  • This paper presents a fault location algorithm based on the adaptively estimated value of the local sequence source impedance for faults on a parallel transmission line. This algorithm uses only the local voltage and current signals of a faulted circuit. The remote current signals and the zero-sequence current of the healthy adjacent circuit are calculated by using the current distribution factors together with the local terminal currents of the faulted circuit. The current distribution factors consist of local equivalent source impedance and the others such as fault distance, line impedance and remote equivalent source impedance. It means that the values of the current distribution factors can change according to the operation condition of a power system. Consequently, the accuracy of the fault location algorithm is affected by the two values of equivalent source impedances, one is local source impedance and the other is remote source impedance. Nevertheless, only the local equivalent impedance can be estimated in this paper. A series of test results using EMTP simulation data show the effectiveness of the proposed algorithm. The proposed algorithm is valid for a double-circuit transmission line system where the equivalent source impedance changes continuously.

Current-Type Nine-Switch Inverters

  • Dehghan, Seyed Mohammad;Mohamadian, Mustafa;Yazdian, Ali
    • Journal of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.146-154
    • /
    • 2010
  • In this paper two dual output current-type inverters are proposed. These inverters have been called a current source nines-witch inverter and a current-type z-source nine-switch inverter by the authors. The proposed inverters have two independent current source outputs. Compared to two independent current source inverters, the proposed converters are implemented with fewer semiconductor switches. Space vector modulation (SVM) is proposed for these converters. Simulation results show the validity and performance of the proposed inverters.

Current Control of a Single-phase PWM Converter under the Distorted Source Voltage and Frequency Condition (전원 전압 왜곡과 주파수 변동 시 단상 PWM 컨버터의 전류 제어)

  • Ahn, Chang-Heon;Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.356-362
    • /
    • 2015
  • This paper presents a current control strategy in the synchronous reference frame for a single-phase PWM converter, which ensures sinusoidal input current control under the distorted source voltage and frequency condition. Given that the distorted source voltage distorts the phase angle for PWM converter control, the input current contains the same harmonics as the source voltage. Aside from the distorted voltage, the variation in source frequency reduces the performance of input current control. To achieve sinusoidal input current control under the distorted source voltage and frequency condition, this paper proposes a compensation strategy of current reference with the distortion component extracted from the phase angle and a detection strategy of frequency variation from the output of a synchronous reference frame phase-lock loop. The experimental results confirm the validity of the proposed method under the distorted source voltage and frequency condition.

Design and Implementation of High Power Source Measurement Unit (고 전력 Source Measurement Unit의 설계 및 제작)

  • Lee, Sang-Gu;Baek, Wang-Gi;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.860-863
    • /
    • 2003
  • In this paper high power SMU(Source Measurement Unit) having 50V/1.5A source/measure range has been designed and implemented. The SMU has two operation mode, voltage mode and current mode. The SMU can be used as variable voltage source, variable current source, voltage meter, or current meter. Combining two different unit, output power can be doubled as 100V/1.5A. The developed SMU tan be used many semiconductor testing system and electronic device inspecting system.

  • PDF

Two Modified Z-Source Inverter Topologies - Solutions to Start-Up Dc-Link Voltage Overshoot and Source Current Ripple

  • Bharatkumar, Dave Heema;Singh, Dheerendra;Bansal, Hari Om
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1351-1365
    • /
    • 2019
  • This paper proposes two modified Z-source inverter topologies, namely an embedded L-Z-source inverter (EL-ZSI) and a coupled inductor L-Z source inverter (CL-ZSI). The proposed topologies offer a high voltage gain with a reduced passive component count and reduction in source current ripple when compared to conventional ZSI topologies. Additionally, they prevent overshoot in the dc-link voltage by suppressing heavy inrush currents. This feature reduces the transition time to reach the peak value of the dc-link voltage, and reduces the risk of component failure and overrating due to the inrush current. EL-ZSI and CL-ZSI possess all of the inherent advantages of the conventional L-ZSI topology while eliminating its drawbacks. To verify the effectiveness of the proposed topologies, MATLAB/Simulink models and scaled down laboratory prototypes were constructed. Experiments were performed at a low shoot through duty ratio of 0.1 and a modulation index as high as 0.9 to obtain a peak dc-link voltage of 53 V. This paper demonstrates the superiority of the proposed topologies over conventional ZSI topologies through a detailed comparative analysis. Moreover, experimental results verify that the proposed topologies would be advantageous for renewable energy source applications since they provide voltage gain enhancement, inrush current, dc-link voltage overshoot suppression and a reduction of the peak to peak source current ripple.