• 제목/요약/키워드: Current-fed

검색결과 790건 처리시간 0.029초

전압 이득이 향상된 단상 전류형 qZ-소스 인버터 (Enhanced Voltage Gain Single-Phase Current-Fed qZ-Source Inverter)

  • 신현학;차헌녕;김흥근
    • 전력전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.305-311
    • /
    • 2013
  • This paper proposes a performance improvement of existing single-phase current-fed qZ-Source inverter. Voltage gain of the traditional voltage-fed full-bridge inverter and single-phase current-fed qZ-source inverter is only equal to or smaller than input voltage. The proposed inverter can obtain twice higher voltage gain than the single-phase current-fed qZ-Source inverter by adding an extra switch and a capacitor in the circuit. In addition, the proposed inverter shares the common ground between dc input and ac output voltage. Therefore, the proposed inverter can eliminate the possible ground leakage current problem when it is used for grid-tied photovoltaic inverter system. A 120 W prototype inverter is built and tested to verify performances of the proposed inverter.

전류형 능동 교류 전력 필터의 해석 (Analysis of Current-Fed Active AC Power Filters)

  • Choe, Gyu-Ha
    • 대한전기학회논문지
    • /
    • 제38권6호
    • /
    • pp.441-450
    • /
    • 1989
  • A control technique for current-fed filters is proposed which not only eliminates the harmonic current, but also controls the reactive power at the ac sides of PWM inverter-induction motor drive system. Injecting the proposed PWM current enables the harmonic components of orders not greater than the number of pulses per half-cycle to be removed completely. Also it enables the input fundamental power factor to become unity and hence total input power factor can be improved greatly. Digital simulation is performed to investigate the theoretical output characteristics of the current-fed filters by the proposed control technique.

  • PDF

연료전지 응용을 위한 HF Link 전류원 인버터 (HE Link Current-Fed Inverter for Fuel Cell Applications)

  • 정세교;신휘범;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.17-20
    • /
    • 2003
  • This paper presents a high frequency (HF) link current-fed inverter fur fuel cell applications. The circuit topology, operation and control method of the proposed HF link current-fed inverter are presented. The active cancellation technique of the 120Hz input harmonic current is also considered. The simulation results are provided to show the feasibility of the proposed inverter scheme.

  • PDF

5'' True Color FED 구동시스템 설계 (Design of 5'' True Color FED Driving System)

  • 신홍재;권오경;곽계달
    • 전자공학회논문지SC
    • /
    • 제38권5호
    • /
    • pp.70-78
    • /
    • 2001
  • 본 연구에서는 전류제어 효과를 갖는 전압제어 펄스폭 변조 방식의 5' true color FED 구동시스템을 설계하였다. 제안한 구동방식은 전압제어 펄스폭 변조방식과 전류제어 방식의 장점을 가지고 있다. 또한, FED 구동회로의 시뮬레이션을 위하여 FED 서브 픽셀에 대한 새로운 회로 모델을 제안한다. 제안된 모델은 FED 서브 픽셀의 특성과 FED 패널의 기생 효과인 게이트 라인간 커플링 현상과 인접한 캐소드 라인을 통하여 흐르는 누설 전류 등을 고려하고 있다. FED 구동회로의 출력단은 제안된 모델을 사용하여 최적화되었다. R.G.B 입력데이터 신호 처리를 병렬처리 방식으로 하여 기존의 직렬처리 방식에 비해서 화면에 영상을 디스플레이하는 duty ratio를 최대로 하여 휘도를 높일 수 있도록 하였다. 이러한 연구 결과를 바탕으로 $300{\times}224$의 해상도를 가지는 5' true color FED를 성공적으로 디스플레이 하였다.

  • PDF

전압원 및 전류원 구동 공진형 인버터로 구성된 형광등용 전자식 안정기의 역률개선에 적합한 수동 역률 개선 회로에 관한 연구 (Passive Power Factor Correction Circuits for Electronic Ballasts using Voltage-Fed and Current-Fed Resonant Inverters)

  • 채균;류태하;조규형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.266-269
    • /
    • 1999
  • Several power factor correction(PFC) circuits are presented to achieve high PF electronic ballast for both voltage-fed and current-fed electronic ballast. The proposed PFC circuits use valley-fill(VF) type DC-link stages modified from the conventional VF circuit to adopt the charge pumping method for PFC operations during the valley intervals. In voltage-fed ballast, charge pump capacitors are connected with the resonant capacitors. In current-fed type, the charge pump capacitors are connected with the additional secondary-side of the power transformer. The measured PF and THD are higher than 0.99 and 15% for all proposed PFC circuits. The lamp current CF is also acceptable in the proposed circuits. The proposed circuit is suitable for implementing cost-effective electronic ballast.

  • PDF

Analysis and Design of a Current-fed Two Inductor Bi-directional DC/DC Converter using Resonance for a Wide Voltage Range

  • Noh, Yong-Su;Kim, Bum-Jun;Choi, Sung-Chon;Kim, Do-Yun;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1634-1644
    • /
    • 2016
  • In this paper, a current-fed two-inductor bi-directional DC/DC converter using resonance (CF-TIBCR) and its design method are proposed. The CF-TIBCR has characteristics of low current ripple and a high current rating because of two separated inductors. Also, it achieves zero voltage switching for all switches and zero current switching for switches of a low voltage stage by using the resonant tank. Besides, a voltage spike problem in conventional current-fed converters is solved without the need for an additional snubber or clamping circuits. As a result, the CF-TIBCR features high step-up and high efficiency. Since the proposed converter has difficulty achieving the soft-switching condition when the converter requires the low voltage transfer ratio, a method that varies the number of resonant cycles is adopted to extend the output voltage range with satisfying the soft-switching condition. The principles of the operation characteristics are presented with a theoretical analysis, and the proposed converter is verified through results of an experiment using a laboratory prototype.

SINGLE-PHASE CURRENT SOURCE INVERTER WITH PULSE AREA MODULATION SCHEME FOR SOLAR POWER CONDITIONER

  • Hirachi, K.;Matsumoto, K.;Ishitobi, M.;Ishibashi, M.;Nakaoka, M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.724-729
    • /
    • 1998
  • In general, a single-phase current-fed PWM inverter using IGBTs has some unique advantages for small scale distributed utility-interactive power supply system as compared with voltage-fed PWM inverter. In particular, this is more suitable and acceptable for a non-isolated type utility-interactive power conditioner, which is going to be widely used for residential solar photovoltaic (PV) power generation system in Japan. However, this current-fed PWM inverter has a significant disadvantage. The output current of this inverter includes large harmonic contents when the inductance of smoothing reactor in its DC side is not large enough to eliminate its current ripple components of this inverter. In order to overcome this problem, a new conceptual pulse area modulation scheme for this inverter is introduced in difference with conventional PWM strategy. This paper presents a new effective control implementation of this PV power conditioner which is able to reduce the harmonic component in the output current produced by the single-phase current-fed PWM inverter even when the ripple current in the smoothing DC reactor is relatively large. The operating principle of the proposed control strategy introdued for this inverter system is described, and its simulation results are evaluated and discussed herein.

  • PDF

전류형 Z-Source 컨버터를 이용한 새로운 LED 전류 밸런싱 기법 (New LED Current Balancing Scheme Using C-Fed Z-Source Converter)

  • 홍다헌;차헌녕
    • 전력전자학회논문지
    • /
    • 제26권1호
    • /
    • pp.9-15
    • /
    • 2021
  • In multi-string light-emitting diode (LED) driver system, current balancing is crucial because the brightness of LED is directly related to its forward current. This paper presents a novel LED current balancing topology using current-fed Z-source converter. With the proposed structure, currents flowing through two LED strings are automatically balanced owing to the charge-balance condition on capacitors. Operation of the proposed converter is simple and the proposed converter uses only one active switch and one diode. Moreover, low-side gate driving can be used to operate the active switch. To verify the operation of the proposed LED current balancing converter, a prototype is built and tested with different numbers of LEDs.

An Improved Topology for the Current Fed Parallel Resonant Half Bridge Circuits Used in Fluorescent Lamp Electronic Ballasts

  • Wang, Qingsong;Cheng, Ming;Zhang, Bing
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.567-575
    • /
    • 2015
  • An improvement in the current fed parallel resonant half bridge (CFPRHB) circuits used in fluorescent lamp electronic ballasts is provided in this paper. The CFPRHB belongs to the self-oscillating family which includes the current fed push-pull and series resonant inverters, most of which are used in instant-start applications. However, many failure modes are related to the bypass capacitor according to an analysis of failed samples. In this paper, the operating functions of the existing topology in the steady state are analyzed and the main root cause of failure modes has been found. Comparisons between the two topologies are conducted in terms of the voltage stress of the bypass capacitor as well as the thermal and performance of the ballasts to verify the advantages of the proposed topology. It is found that the improved topology is capable of enhancing the reliability and reducing the cost of products without having a negative influence on the system performance.

지중케이블 변전소의 고장전류 분류율과 접지전위상승 특성 (Characteristics of Fault Current Division Factor & Groud Potential Rise of a Substation fed exclusively by Power Cables)

  • 최종기;정길조;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.295-297
    • /
    • 1998
  • This paper shows characteristics of fault current division factor $S_f$, which is a ratio of earth- return current to total fault current, at a substation fed exclusively by power cables under unsymmetrical fault condition, such as single line-to-ground fault. In substation grounding system design, $S_f$ is a very important factor determining GPR, touch and step voltage at a substation under fault condition. In case of substations fed by overhead lines, 40-60% of $S_f$ has been typically used, although it is a very conservative value with no other network conditions considered. It is authors' hope that $S_f$ presented in this paper could hopefully be a basic reference in designing of substation grounding system, especially for a substation fed exclusively by power cables.

  • PDF