• Title/Summary/Keyword: Cut-off angle

Search Result 84, Processing Time 0.022 seconds

Effect of Cut-off Angle on Flow Pattern of Centrifugal Multi-blade Fan (원심 다익홴의 유동에 대한 컷 오프 각도의 영향)

  • Kang, Kyung-Jun;Shin, You-Hwan;Lee, Yoon-Pyo;Kim, Kwang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.3
    • /
    • pp.37-42
    • /
    • 2010
  • This study investigated on details of flow characteristics of a multi-blade fan for domestic ventilation. Experiments and analysis were carried out to describe on flow pattern with variations of cut-off angle near the scroll housing throat, which were performed by PIV measurement for the flow field and by total pressure probes. The stagnation point at cut-off region of the fan moves to the exit of the scroll housing as the cut-off angle increases. The movement of stagnation point and the variation of throat area of the scroll housing influence to the distribution of velocity magnitude at the exit of the fan. Furthermore, a large distortion of the velocity distribution at the scroll exit causes to increase mixing loss along the flow path.

Shape Optimization of Cut-Off in Multiblade Fan/Scroll System Using CFD and Neural Network (신경망 기법을 이용한 다익 홴/스크롤 시스템의 컷오프 최적화)

  • Han, S.Y.;Maeng, J.S.;Yoo, D.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.365-370
    • /
    • 2001
  • In order to minimize unstable flow occurred at a multiblade fan/scroll system, optimal angle and shape of cut-off was determined by using two-dimensional turbulent fluid field analyses and neural network. The results of CFD analyses were used for learning as data of input and output of neural network. After learning neural network optimization process was accomplished for design variables, the angle and the shape of cut-off, in the design domain. As a result of optimization, the optimal angle and shape were obtained as 71 and 0.092 times the outer diameter of impeller, respectively, which are very similar values to previous studies. Finally, it was verified that the fluid field is very stable for optimal angle and shape of cut-off by two-dimensional CFD analysis.

  • PDF

Some Relations Between the Geometric Parameters and Internal Flow Field Characteristics in Multiblade Fan/Scroll System (다익 홴/스크롤 시스템의 형상변수와 내부 유동장 특성과의 관계)

  • Maeng, Joo-Sung;Yoo, Dal-Hyun;Lee, Kwang-Ho;Park, ln-Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.9
    • /
    • pp.1139-1147
    • /
    • 2000
  • This paper describes that the size of inactive zone can be directly applied to design multiblade fan/scroll system. From the experimental studies using a five hole pitot tube and smoke test, it is found that the size of inactive zone has linear relations with the mean velocity of impeller inlet and cut-off angle gives a great influences to the fan efficiency. For the practical design, a function related with geometric parameters(i.e. inner radius, cord length, cut-off clearance and cut-off angle) of fan/scroll system is suggested. By using these formulas, the size and distribution of inactive zone can be predicted without the measurements through the full domain, it can be possible to use them to know the efficiency improvement for new model designed.

Experimental Study on the Aerodynamic Performance of Double Inlet Sirocco Fan for a Package Air Conditioner (PAC용 양흡입 시로코홴의 공력성능에 관한 실험적 연구)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.58-63
    • /
    • 2013
  • The aerodynamic performance of double inlet sirocco fan is strongly dependent upon the design factors of impeller and scroll. In this paper, the change of scroll size was adopted to investigate the aerodynamic performances of double inlet sirocco fan and indoor PAC. Especially, a scroll expansion angle and a cut-off clearance ratio were considered to change the scroll size. In addition, the installation depth between double inlet sirocco fan and indoor PAC was considered. As a result, the total pressure efficiency of double inlet sirocco fan shows about 62%~73% according to the change of scroll expansion angles. Moreover, the flowrate performance of indoor PAC is the best at the condition of a scroll expansion angle of 8°, an installation depth of 15 mm and a cut-off clearance ratio of 8%.

Shape Optimization of Cut-Off in a Multi-blade Fan/Scroll System Using Neural Network (신경망 최적화 기법을 이용한 다익 홴/스크롤 시스템의 설부에 대한 형상 최적화)

  • Han, Seog-Young;Maeng, Joo-Sung;Yoo, Dal-Hyun;Jin, Kyong-Uk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.10
    • /
    • pp.1341-1347
    • /
    • 2002
  • In order to improve efficiency of a system with three-dimensional flow characteristics, this paper presents a new method that overcomes three-dimensional effects by using two-dimensional CFD and neural network. The method was applied to shape optimization of cut-off in a multi-blade fan/scroll system. As the entrance conditions of two-dimensional CFD, the experimental values at the positions out of the inactive zone were used. The distributions of velocity and pressure obtained by two-dimensional CFD were compared with those of three-dimensional CFD and experimental results. It was found that the distributions of velocity and pressure have qualitative similarity. The results of two-dimensional CFD were used for teaming as target values of neural network. The optimal angle and radius of cut-off were determined as 71$^{\circ}$and 0.092 times the outer diameter of impeller, respectively. It is quantified in the previous report that the optimal angle and radius of cut-off are approximately 72$^{\circ}$and 0.08 times the outer diameter of impeller, respectively.

Shape Optimization of Cut-Off in a Multi-blade Fan/Scroll System Using Response Surface Method (반응표면법을 이용한 다익 홴/스크롤 시스템의 설부에 대한 형상 최적화)

  • 한석영;맹주성;황영민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.1
    • /
    • pp.225-231
    • /
    • 2003
  • In order to improve efficiency of a system with three-dimensional flow characteristics, this paper presents a new method that overcomes three-dimensional effects by using two-dimensional CFD and response surface method. The method was applied to shape optimization of cut-off in a multi-blade fan/scroll system. As the entrance conditions of two-dimensional CFD, the experimental values at the positions out of the inactive zone were used. In order to examine the validity of the two-dimensional CFD the distributions of velocity and pressure obtained by two-dimensional CFD were compared with those of three-dimensional CFD and experimental results. It was found that the distributions of velocity and pressure show qualitatively similarity. The results of two-dimensional CFD were used for constructing the objective function with design variables using response surface method. The optimal angle and radius of cut-off were determined as $72.4^{\circ}$ and 0.092 times the outer diameter of impeller, respectively. It is quantified the previous report that the optimal angle and radius of cut-off are approximately $72^{\circ}$ and 0.08 times the outer diameter of impeller, respectively.

Correction and Evaluation for Color Aberration on the Cut-off Line of a Vehicle Headlamp (차량용 헤드램프의 Cut-off Line에서 색수차 보정 및 평가)

  • Shim, Ju Yong;Park, Sung-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.1
    • /
    • pp.8-14
    • /
    • 2019
  • This paper presents methods to correct and evaluate the chromatic aberration occurring on the cut-off line of a headlamp without additional optical components and alignment process. To correct the chromatic aberration using a geometrical concept, the maximum differences in exit-ray angle between wavelengths are reduced by tilting the convex surface of an aspheric projection lens. To evaluate the chromatic aberration, the position and luminous intensity to be measured are suggested, and the criterion for chromatic aberration is presented through color coordinates. From the evaluation of an automotive headlamp designed using this geometrical method, it is found that the chromatic aberration of the cut-off line is significantly reduced.

Design of Complementary Filter using Least Square Method (최소자승법을 이용한 상보필터의 설계)

  • Min, Hyung-Gi;Yoon, Ju-Han;Kim, Ji-Hoon;Kwon, Sung-Ha;Jeung, Eun-Tae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.2
    • /
    • pp.125-130
    • /
    • 2011
  • This paper shows a method to design complementary filter using least square. The complementary filter is one of useful filters estimating angle. The basic concept of this filter is to enhance advantages of each sensor that angle detecting using a gyroscope has good accuracy at a high frequency and an accelerometer at a low frequency. When designing complementary filter, the most commonly used method is using cut-off frequency. However, it may be not easy to obtain a cut-off frequency. This paper presents a systematic method to determine the coefficients of the complementary filter using well-known linear least squares minimizing error between estimating angle and true angle.

IR Cut-off Filter Made of CeO2 and SiO2 Thin Films Coated on PMMA Substrate (PMMA 기판에 CeO2와 SiO2를 코팅하여 제작한 적외선 차단필터)

  • Yu, Yeon-Serk;Choi, Sang-Serk
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.480-486
    • /
    • 2006
  • Generally, IR cut-off filters for mobile phone is coated on the glass substrate at high temperature(above $300^{\circ}C$). In this work, we prepared IR cut-off filters on the poly(methyl methacrylate)(PMMA) substrates at low temperature(about $70^{\circ}C$ ). using the $CeO_2\;and\;SiO_2$ coatings by physical vapor deposition. The surface energies of coated and uncoated PMMA, and adhesive properties of IR cut-off filters coatings were examined using contact angle measurements. We demonstrate the improve of mobile phone optical system using these results.

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.