• Title/Summary/Keyword: DGA

Search Result 66, Processing Time 0.032 seconds

The Criteria and Results of the Power Transformer DGA (전력용 변압기 유중가스분석의 기준과 적용결과)

  • Cho, Sung-Min;Shin, Hee-Sang;Kim, Jae-Chul;Kweon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.166-168
    • /
    • 2007
  • The DGA (Dissolved Gases Analysis) technique has been widely using for fault diagnosis of the power transformers. This technique has a high reliability than other techniques. KEPCO (Korea Electric Power Cooperation) has been using DGA technique since KEPCO established the criteria of DGA in 1985. In this paper, we introduce the DGA criteria of KEPCO and analyze the result of DGA. Also we introduce the cases of thoroughgoing inspection of the power transformers caused by DGA and compare the judgment of DGA with the result of throughgoing inspection.

  • PDF

A Result and Pattern of Dissolved Gases Analysis in Kepco (전력용 변압기 유중가스분석 결과와 동향)

  • Cho, Sung-Min;Kim, Jae-Chul;Kweon, Dong-Jin;Koo, Kyo-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.95-96
    • /
    • 2007
  • Dissolved gas analysis (DGA) is one of the most widely used diagnostic tools for detecting and evaluating faults in electrical equipment. However, interpretation of DGA results is often complex and should always be done with care, involving experienced insulation maintenance personnel. KEPCO (Korea Electric Power Cooperation) has been using DGA technique since KEPCO established the criteria of DGA in 1985. In this paper, we introduce the DGA criteria of KEPCO and analyze the result of DGA. Also we sort pattern in result of DGA. Then, relation between pattern and inner inspection was studied. 67 DGA data was used for analyzing pattern. Some patterns have something to do with cause of incipient fault.

  • PDF

DGA-based Botnet Detection Technology using N-gram (N-gram을 활용한 DGA 기반의 봇넷 탐지 방안)

  • Jung Il Ok;Shin Deok Ha;Kim Su Chul;Lee Rock Seok
    • Convergence Security Journal
    • /
    • v.22 no.5
    • /
    • pp.145-154
    • /
    • 2022
  • Recently, the widespread proliferation and high sophistication of botnets are having serious consequences not only for enterprises and users, but also for cyber warfare between countries. Therefore, research to detect botnets is steadily progressing. However, the DGA-based botnet has a high detection rate with the existing signature and statistics-based technology, but also has a high limit in the false positive rate. Therefore, in this paper, we propose a detection model using text-based n-gram to detect DGA-based botnets. Through the proposed model, the detection rate, which is the limit of the existing detection technology, can be increased and the false positive rate can also be minimized. Through experiments on large-scale domain datasets and normal domains used in various DGA botnets, it was confirmed that the performance was superior to that of the existing model. It was confirmed that the false positive rate of the proposed model is less than 2 to 4%, and the overall detection accuracy and F1 score are both 97.5%. As such, it is expected that the detection and response capabilities of DGA-based botnets will be improved through the model proposed in this paper.

Improvement in Transformer Diagnosis by DGA using Fuzzy Logic

  • Dhote, Nitin K.;Helonde, J.B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.615-621
    • /
    • 2014
  • Power transformer is one of the most important equipments in electrical power system. The detection of certain gases generated in transformer is the first indication of a malfunction that may lead to failure if not detected. Dissolved gas analysis (DGA) of transformer oil has been one of the most reliable techniques to detect the incipient faults. Many conventional DGA methods have been developed to interpret DGA results obtained from gas chromatography. Although these methods are widely used in the world, they sometimes fail to diagnose, especially when DGA results falls outside conventional method codes or when more than one fault exist in transformer. To overcome these limitations, fuzzy inference system (FIS) is proposed. 250 different cases are used to test the accuracy of various DGA methods in interpreting the transformer condition.

Internal Defect Analysis of Transformers using DGA (유중가스분석을 통한 변압기 내부결함 분석)

  • Kim, Seong-Hwan;Park, Tae-Sik
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.354-359
    • /
    • 2020
  • DGA(Dissolved Gas Analysis) is regularly performed to detect internal defects of power transformers and prevent failures. The overheating or discharging in the transformer can be confirmed by DGA but the defective parts should be identified by internal inspection. However, winding or iron core defects cannot be checked by internal inspection, so it is impossible to establish actions by DGA alone. In this paper, the internal defect mode is analyzed and presented based on the transformer internal inspection reports, and the internal defect can be predicted by considering DGA.

A study on Cause of Errors of Dissolved Gases Analysis in Transformer (변압기 유중 가스 진단 오차 원인에 대한 연구)

  • Cho, Sung-Min;Lee, Yang-Jin;Kim, Young-Sung;Kim, Jae-Chul;Kweon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.141-143
    • /
    • 2006
  • Dissolved gas analysis (DGA) is widely used to detect incipient faults in oil-filled electrical equipment. KEPCO make a rule of DGA in 1985. They have been diagnosing power transformer using their DGA criteria. In this paper, we analysis the result of DGA data about transformer in the substation. We try to find out what is cause of an error in DGA diagnosis considering accuracy in extracting gases from mineral oil in transformer. The carbon-monoxide was primary reason of warning in DGA data. We specially consider that aging is a cause of generating of carbon-monoxide in power transformer.

  • PDF

Intelligent Diagnosis System for DGA Using Fuzzy Pattern Classification and Neural Network (퍼지 패턴 분류와 뉴럴 네트워크를 이용한 지능형 유중가스 판정 시스템)

  • Cho, Sung-Min;Kweon, Dong-Jin;Nam, Chang-Hyun;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2084-2090
    • /
    • 2007
  • The DGA (Dissolved Gases Analysis) technique has been widely using for fault diagnosis of the power transformers. Some electric power utility company establishes the criteria of DGA to improve reliability, because of difference of operation environment and design of power transformer. In this paper, we introduce intelligent diagnosis system for DGA result of KEPCO (Korea Electric Power Cooperation). This system can classify patterns type of gases ratio that frequently occurs in recent result of gases analysis using Fuzzy Inference. The classification of Patterns let us know that major causes of gases generation based on type of patterns. Finally, Neural Network based on patterns diagnose transformer. NN was trained using result data of DGA of actually faulted transformers recently. Result of intelligent diagnosis system is right well in comparison with actual inner inspection of transformers.

The Study of Effect and Safety related to Dong-gi Acupuncture(DGA) and Complex therapy on Lumbago due to blood stasis and sprain (좌섬(挫閃)·어혈(瘀血) 요통(腰痛)에 동기침법(動氣鍼法) 및 복합치료(複合治療)의 유효성(有效性) 및 안정성(安定性) 연구(硏究))

  • Kim, Kee-Hyun;Lim, Hyung-Ho;Hwang, Hyeon-Seo;Song, Ho-Sueb;Song, Young-Sang;Kwon, Soon-Jung;Kim, Kyung-Nam;Ahn, Koang-Hyun;Lee, Seong-No;Kang, Mi-Suk;Gyun, Im-Jung
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.107-114
    • /
    • 2002
  • Objective : This study was designed to find the most effective and safest way to overcome Lumbago due to blood stasis and sprain involved in a few Meridian Tendino-musculatures by evaluating the effect of two kinds of Dong-gi(Dong-qi) Acupuncture(DGA) and by reporting their side effects. Material : 97 patients of out and admission patients were selected, who were diagnosed with lumbar sprain caused by repetitive bending, heavy weight lifting, unsuitable posture, concussion and falling down and whose Lumbago due to blood stasis and sprain in the concept of oriental medicine. Methods : 97 patients were divided into three groups. One is exclusive DGA group to which DGA and the method retaining needles on the acupoints for about 20 minutes were applied, the other is DGA combined active exercise group in which patients stretched their Meridian Tendino-muscuIatures with their hips moving up and downward repeatedly during DGA, the third is DGA combined passive exercise group in which patients were made to flex or extend their bodies on the auto flexion-distraction table in a prone position, from 10 to 20 degree, during DGA. In each group, bed rest, physical therapy and herbal medicine were used according to symptoms, in addition to DGA. In DGA method, "Su(Shu)" points of the meridian related to the involved Meridian Tendino-musculature were mainly chosen, that is, Sokkol(Shugu, B65), Hugye(Houxi, SI3), ChungJo(Zhongzhu, TE3) were used, for most LBP belonged to Bladder and Gallbladder Meridian Tendino-musculature disorders. Pyong-Bo-Pyong-Sa(Ping-Bu-Ping-Xie) such as Dong-Gi and Yeom-Jeon(Nian-Zhuan) was applied as Bo-Sa method. For evaluation of effectiveness, new score system was devised by severity of pain and range of movement. the score was given twice at patients' first and last visit and the difference between first and last score was regarded as a evaluation scale, the effectiveness was classified into four grade by evaluation scale.(scale : 12-15; excellent, 8-11; good, 4-7; fair, 0-3; bad) Results : 1. Exclusive DGA, DGA combined active exercise and DGA combined passive exercise group showed 97, 87 and 89% in effectiveness. 2. Exclusive DGA, DGA combined active exercise and DGA combined passive exercise group showed no aggravation of pain, range of movement. 3. In blood test of 34 patients, only one patient showed abnormal rise of sGOT, sGPT and $\gamma$-GTP at his first visit and the others didn't show any detrimental change. DGA had no bad influence upon BUN and creatinine of patients. Conclusion : For complex theraphy combining DGA, exercise, physical therapy and Herbal medicine proved to be highly effective on treating lumbago due to blood stasis and sprain, this is expected to be available for clinical use.

  • PDF

DGA-DNS Similarity Analysis and APT Attack Detection Using N-gram (N-gram을 활용한 DGA-DNS 유사도 분석 및 APT 공격 탐지)

  • Kim, Donghyeon;Kim, Kangseok
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.5
    • /
    • pp.1141-1151
    • /
    • 2018
  • In an APT attack, the communication stage between infected hosts and C&C(Command and Control) server is the key stage for intrusion into the attack target. Attackers can control multiple infected hosts by the C&C Server and direct intrusion and exploitation. If the C&C Server is exposed at this stage, the attack will fail. Therefore, in recent years, the Domain Generation Algorithm (DGA) has replaced DNS in C&C Server with a short time interval for making detection difficult. In particular, it is very difficult to verify and detect all the newly registered DNS more than 5 million times a day. To solve these problems, this paper proposes a model to judge DGA-DNS detection by the morphological similarity analysis of normal DNS and DGA-DNS, and to determine the sign of APT attack through it, then we verify its validity.

A Study on the Development of DGA based on Deep Learning (Deep Learning 기반의 DGA 개발에 대한 연구)

  • Park, Jae-Gyun;Choi, Eun-Soo;Kim, Byung-June;Zhang, Pan
    • Korean Journal of Artificial Intelligence
    • /
    • v.5 no.1
    • /
    • pp.18-28
    • /
    • 2017
  • Recently, there are many companies that use systems based on artificial intelligence. The accuracy of artificial intelligence depends on the amount of learning data and the appropriate algorithm. However, it is not easy to obtain learning data with a large number of entity. Less data set have large generalization errors due to overfitting. In order to minimize this generalization error, this study proposed DGA which can expect relatively high accuracy even though data with a less data set is applied to machine learning based genetic algorithm to deep learning based dropout. The idea of this paper is to determine the active state of the nodes. Using Gradient about loss function, A new fitness function is defined. Proposed Algorithm DGA is supplementing stochastic inconsistency about Dropout. Also DGA solved problem by the complexity of the fitness function and expression range of the model about Genetic Algorithm As a result of experiments using MNIST data proposed algorithm accuracy is 75.3%. Using only Dropout algorithm accuracy is 41.4%. It is shown that DGA is better than using only dropout.