• Title/Summary/Keyword: DRRs

Search Result 14, Processing Time 0.021 seconds

A Study on the Cross-Polarization Interference Canceller of Radio Relay System for Spectral Efficiency Enhancement (주파수 효율 향상을 위한 무선 중계장치의 직교편파 간섭제거기에 관한 연구)

  • 서경환
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.25-28
    • /
    • 2001
  • In this paper. to eliminate a cross-polarization interference caused by co-channel dual polarization technique of digital radio relay system(DRRS), a cross-polarization interference canceller(XPIC) is analysed in terms of the analytical modeling, digital design, and its performance. By virtue of a 13-tap adaptive equalizer and XPIC, about 23dB in XPIC improvement can be obtained by computer simulation. To show the operation of designed XPIC, some simulated results are reviewed under 64-QAM DRRS with co -channel dual Polarization.

  • PDF

Monte Carlo Simulation Based Digitally Reconstructed Radiographs

  • Kakinohana, Yasumasa;Ogawa, Kazuhiko;Toita, Takafumi;Murayama, Sadayuki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.436-438
    • /
    • 2002
  • As the use of virtual simulation expands, digitally reconstructed radiographs (DRRs), which mimic conventional simulation films, play an increasingly important role as reference images in the verification of treatment fields. The purpose of our study is to develop an algorithm for computation of digitally reconstructed radiographs based on Monte Carlo simulation that take into account almost all possible physical processes by which photons interact with matter. The Monte Carlo simulation based DRRs have the following features. 1) Account has been taken of almost all possible physical processes of interaction of photons with matter, including a detector (film) response. In principle, this is equivalent to X-ray radiography. 2) Arbitrary photon energies (from diagnostic to therapeutic) can be used to produce DRRs. One can even use electrons as the source. 3) It is easy to produce a double exposure, which mimics the double exposure portal image and may have superior visual appeal for treatment field verification, with weighting within the treatment field.

  • PDF

Analysis of Uncertainties due to Digitally Reconstructed Radiographic (DRR) Image Quality in 2D-2D Matching between DRRs and kV X-ray Images from the On-Board Imager (OBI) (디지털 재구성 방사선영상과 온보드 영상장치를 이용한 2D-2D 정합 시 디지털 재구성 방사선영상의 질이 정합 정확도에 미치는 영향 분석)

  • Cheong Kwang-Ho;Cho Byung-Chul;Kaug Sei-Kwon;Kim Kyoung-Joo;Bae Hoon-Sik;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.67-76
    • /
    • 2006
  • We evaluated the accuracy of a patient setup error correction due to reference image quality for a 2D-2D matching process. Digitally reconstructed radiographs (DRRs) generated by use of the Pinnacle3 and the Eclipse for various regions of a humanoid phantom and a patient for different CT slice thickness were employed as a reference images and kV X-ray Images from the On-Board Imager were registered to the reference DRRs. In comparison of the DRRs and profiles, DRR image quality was getting worse with an increase of CT image slice thickness. However there were only slight differences of setup errors evaluation between matching results for good and poor reference DRRs. Although DRR image quality did not strongly affect to the 2D-2D matching accuracy, there are still potential errors for matching procedure, therefore we recommend that DRR images are needed to be generated with less than 3mm slice thickness for 2D-2D matching.

  • PDF

DRRS : An Implementation Case of Federation and Replication for ebXML Registry and Repository (DRRS: ebXML 정보등록저장소를 위한 Federation and Replication 구현 사례)

  • Lee Youngkon;Jang Jasmine
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.11a
    • /
    • pp.531-534
    • /
    • 2004
  • 기업간 전자상거래 국제 표준인 ebXML 의 표준 사양에 따른 정보등록저장소를 활용하여 각 산업별 B2B 표준 컨텐츠를 저장, 등록, 관리하는 사례가 증가하고 있다. 각 산업별 기관별 등록저장 소가 만들어지고 또한 국가별로도 중앙등록저장소가 구현됨에 따라 이들을 서로 연계하여 산업간의 B2B 활용도를 높이고 또한 연동성을 향상시킬 수 있는 방안을 찾고 있는 중이다. 이미 OASIS에서는 Federation 및 Replication 기능을 추가한 ebRS 2.5 버전 사양에 대한 드래프트를 제시하였고 표준으로 승인받기 위한 절차를 진행 중에 있다. 본 논문에서는 한국전자거래진흥원의 지원하에 개발된 정보등록저장소의 Federation 및 Replication 처리시스템의 개발방법에 대해 살펴보고 현실에 적용할 때에 발생할 수 있는 제반 프로토콜상에서의 문제점 및 해결방안에 대해 논의해 보고자 한다.

  • PDF

Risk-Based Allocation of Demand Response Resources Using Conditional Value-at Risk (CVaR) Assessment

  • Kim, Ji-Hui;Lee, Jaehee;Joo, Sung-Kwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.789-795
    • /
    • 2014
  • In a demand response (DR) market run by independent system operators (ISOs), load aggregators are important market participants who aggregate small retail customers through various DR programs. A load aggregator can minimize the allocation cost by efficiently allocating its demand response resources (DRRs) considering retail customers' characteristics. However, the uncertain response behaviors of retail customers can influence the allocation strategy of its DRRs, increasing the economic risk of DRR allocation. This paper presents a risk-based DRR allocation method for the load aggregator that takes into account not only the physical characteristics of retail customers but also the risk due to the associated response uncertainties. In the paper, a conditional value-at-risk (CVaR) is applied to deal with the risk due to response uncertainties. Numerical results are presented to illustrate the effectiveness of the proposed method.

Radiation Oncology Digital Image Chart 8nd Digital Radiotherapv Record System at Samsung Medical Center (디지털 화상 병력 시스템과 디지털 방사선치료 기록 시스템의 개발과 사용 경험)

  • Huh Seung Jae;Ahn Yong Chan;Lim Do Hoon;Cho Chung Keun;Kim Dae Yong;Yeo Inhwan;Kim Moon Kyung;Chang Seung Hee;Park Suk Won
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.67-72
    • /
    • 2000
  • Background :The authors have developed a Digital image chart(DIC) and digital Radiotherapy Record System (DRRS). We have evaluated the DIC and DRRS for reliability, usefulness, ease of use, and efficiency. Materials and Methods :The basic design of the DIC and DRRS was to build an digital image database of radiation therapy Patient records for a more efficient and timely flow of critical image information throughout the department. This system is a submit of comprehensive radiation oncology management system (C-ROMS) and composed of a picture archiving and communication system (PACS), a radiotherapy information database, and a radiotherapy imaging database. The DIC and DRRS were programmed using Delphi under a Windows 95 environment and is capable of displaying the digital images of patients identification photos, simulation films, radiotherapy setup, diagnostic radiology images, gross lesion Photos, and radiotherapy Planning isodose charts with beam arrangements. Twenty-three clients in the department are connected by Ethernet (10 Mbps) to the central image server (Sun Ultra-sparc 1 workstation). Results :From the introduction of this system in February 1998 through December 1999, we have accumulated a total of 15,732 individual images for 2,556 patients. We can organize radiation therapy in a 'paperless' environment in 120 patients with breast cancer. Using this system, we have succeeded in the prompt, accurate, and simultaneous access to patient care information from multiple locations throughout the department. This coordination has resulted in improved operational efficiency within the department. Conclusion :The authors believe that the DIC and DRRS has contributed to the improvement of radiation oncology department efficacy as well as to time and resource savings by providing necessary visual information throughout the department conveniently and simultaneously. As a result, we can also achieve the 'paperless' and 'filmless' practice of radiation oncology with this system.

  • PDF

A Study on the Design of Cross-Polarization Interference Canceler for Digital Radio Relay System with Co-Channel Dual Polarization (동일 채널 이중편파를 적용하는 디지털 무선 중계장치의 직교편파간섭제거기 설계에 관한 연구)

  • 서경환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.3
    • /
    • pp.225-236
    • /
    • 2002
  • In this paper, to counteract a cross-polarization interference caused by co-channel dual polarization technique of digital radio relay system(DRRS), we analyze the theoretical model and digital design of cross-polarization interference canceller(XPIC). In addition a complex adaptive time domain equalizer(ATDE) is designed using a finite impulse response filter, and the structure of XPIC and its control method are also illustrated including ATDE. Our computer simulation shows that about 25 dB signature and more than 23 dB XPIC improvement factor can be obtained with XPIC and ATDE. In order to verify the operation of designed XPIC, we review the simulated results in view of tap number, algorithm convergence, system signature, and XPlC improvement factor in connection with 64-QAM DRRS with co-channel dual polarization.

Setup Verification in Stereotactic Radiotherapy Using Digitally Reconstructed Radiograph (DRR) (디지털화재구성사진(Digitally Reconstructed Radiograph)을 이용한 정위방사선수술 및 치료의 치료위치 확인)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.84-88
    • /
    • 1999
  • Purpose :To develop a method for verifying a treatment setup in stereotactic radiotherapy by ma- tching portal images to DRRs. Materials and Methods : Four pairs of orthogonal portal images of one patient immobilized by a thermoplastic mask frame for fractionated stereotactic radiotherapy were compared with DRRs. Portal images are obtained in AP (anteriorfposterior) and lateral directions with a target localizer box containing fiducial markers attached to a stereotactic frame. DRRs superimposed over a planned iso-center and fiducial markers are printed out on transparent films. And then, they were overlaid over onhogonal penal images by matching anatomical structures. From three different kind of objects (isgcenter, fiducial markers, anatomical structure) on DRRs and portal images, the displacement error between anatomical structure and isocenters (overall setup error), the displacement error between anatomical structure and fiducial markers (irnrnobiliBation error), and the displacement error between fiducial markers and isocenters (localization error) were measured. Results : Localization error were 1.5$\pm$0.3 mm (AP), 0.9$\pm$0.3 mm (lateral), and immobilization errors were 1.9$\pm$0.5 mm (AP), 1.9$\pm$0.4 mm (lateral). In addition, overall setup errors were 1.0$\pm$0.9 mm (AP), 1.3$\pm$0.4 mm (lateral). From these orthogonal displacement errors, maximum 3D displacement errors($\sqrt{(\DeltaAP)^{2}+(\DeltaLat)^{2}$)) were found to be 1.7$\pm$0.4 mm for localization, 2.0$\pm$0.6 mm for immobilization, and 2.3$\pm$0.7 mm for overall treatment setup. Conclusion : By comparing orthogonal portal images with DRRs, we find out that it is possible to verify treatment setup directly in stereotactic radiotherapy.

  • PDF

Development of Demand Response Operation System for Load Aggregators (부하관리사업자용 수요반응 운영 시스템 개발)

  • Kim, Ji-Hui;Moon, Guk-Hyun;Joo, Sung-Kwan;Oh, Jae-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2221-2224
    • /
    • 2011
  • During an emergency due to a shortage of power, a load aggregator (LA) can use the demand response operation system to deploy demand response resources (DRRs) through various demand response (DR) programs. This paper introduces the demand response operation system for a load aggregator to manage various demand response resources in a smart grid environment.

DNA Repair Capacity in Peripheral Blood Lymphocytes Predicts Efficacy of Platinum-based Chemotherapy in Patients with Gastric Cancer

  • Zhang, Yi-Yin;Gu, Kang-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5507-5512
    • /
    • 2013
  • Objective: To investigate the correlation between ERCC1 expression levels in tumor tissue and peripheral blood lymphocytes (PBL) from patients with gastric cancer and assess the relationship between PBL DNA repair rate (DRR) and the efficacy of platinum chemotherapy. Methods: A total of 53 patients with gastric cancer receiving surgery and 20 controls were studied. ERCC1 protein expression in tumour tissue and PBL were determined by immunohistochemical staining. The PBL DRRs of 47 advanced patients and 20 controls were estimated by comet assay. Results: The positive expression rates of ERCC1 were 67. 9%, 56. 6% and 10.0% in tumour tissues, PBLs of gastric cancer patients, and PBLs of the control group. PBL ERCC1 expression correlated with that in tissue (${\chi}^2$=15. 463, p=0.000). Pearson contingency coefficient=0.475). DRRs of cancer patients by tail length (TL) (Z=4. 662, p=0.000) and tail moment (TM) (Z=3. 827, p=0.000) were significantly lower than that of control group. When TL was applied as an indicator, the correlation between DRR and chemotherapy efficacy was significant (Spearman rank correlation r=0.327, p=0.032). Patients with low levels of DRR in PBL presented better short-term efficacy of chemotherapy than those with high levels of DRR. Conclusions: The ERCC1 expression in PBLs may indirectly reflect ERCC1 expression in gastric cancer tissues. Compared with non-cancer populations, patients with gastric cancer may have lower DNA repair capacity. DRR in PBL may predict the short-term efficacy of platinum-based chemotherapy for patients with advanced gastric cancer.