• Title/Summary/Keyword: D_1%24

Search Result 5,233, Processing Time 0.038 seconds

Noise Exposure Level Measurements for Different Job Categories on Ships (선박의 담당업무에 따른 소음노출레벨 측정에 관한 연구)

  • Im, Myeong-Hwan;Choe, Sang-Bom
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.875-882
    • /
    • 2021
  • To minimize occupational noise induced hearing loss, it is recommended that workers should not be exposed to noise levels exceeding 85 dBA for over 8 h. In the present study, noise exposure levels were measured for seven workers based on their tasks on a training ship. The A-weighted noise exposure level (Lex,24h) was measured by taking into account the A-weighted equivalent continuous sound level (LAeq,i), duration (h) and noise contribution (Lex,24h,i) from the workers' locations. Results are thus obtained for different job categories as follows: officer group Lex,24h=56.1 dB, navigation crew Lex,24h=58.9 dB, navigation cadet Lex,24h=62.0 dB, ship's cook Lex,24h=64.3 dB, engine cadet Lex,24h=91.1 dB, engineer Lex,24h=91.1 dB, and engine crew Lex,24h=95.1 dB. It was determined that the engineers, engine crews, and engine cadets in charge of machinery must wear hearing protection devices. By wearing hearing protection devices when working in highly noisy engine rooms, it is estimated that the noise expose levels could be reduced by the following amounts: engineer Lex,24h=23.1 dB, engine Crew Lex,24h=24.4 dB, and engine cadet Lex,24h=21.5 dB. Moreover, if the no. 2 lecture room and mess room bottom plates in the cadets accommodations were improved to the 64 mm A-60-class floating plates, then further reductions are possible as follows: navigation cadet Lex,24h=4.3 dB and engine cadet Lex,24h=1.8 dB.

2,4-D Biodegradation Using Microorganism Extracted From Soil (1) (토양미생물에 의한 2, 4-D 분해에 관한 연구 (1))

  • Choung, Youn-kyoo;Lee, Byung chan;Kim, Jin-wook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.4
    • /
    • pp.45-53
    • /
    • 1999
  • The microbial organisms named "Pseudomonas sp. LK-14" were isolated from farm land and shallow river sediment, activated, augmented and identified; which were using 2,4-D (2,4-Dichlorophenoxyacetic acid) as a sole carbon source and energy source. 2,4-D removal efficiency of LK-14 with 2,4-D sole carbon source (reactor S) were higher than that of Activated Sludge with 2,4-D sole carbon source (reactor A). Dynamic bioligical reaction kinetic parameters (sole carbon source was 2,4-D) obtained from batch reactor experiments were ${\mu}_{max}$ $0.105hr^{-1}$, $K_{s,24D}$ 15.64mg/L, $K_{i,24D}$ $1.94h^{r-1}$, $Y_{24D}$ 0.39 for LK-14 and ${\mu}_{max}$ $0.008hr^{-1}$, $K_{s,24D}$ 26.95mg/L, $K_{i,24D}$ $1.75hr^{-1}$, $Y_{24D}$ 0.10 for Activated Sludge. Using these parameters, we could predict the behaviors of 2,4-D substrate utilized by LK-14 and Activated Sludge in batch reactors. The kinetic parameters are enable to predict the 2,4-D substrate and microbial population behavior entering into wastewater treatment plants by using unsteady states dynamic simulation modeling technique.

  • PDF

Idiopathic infantile hypercalcemia with severe nephrocalcinosis, associated with CYP24A1 mutations: a case report

  • Yoo, Jeesun;Kang, Hee Gyung;Ahn, Yo Han
    • Childhood Kidney Diseases
    • /
    • v.26 no.1
    • /
    • pp.63-67
    • /
    • 2022
  • Nephrocalcinosis often occurs in infants and is caused by excessive calcium or vitamin D supplementation, neonatal primary hyperparathyroidism, and genetic disorders. Idiopathic infantile hypercalcemia (IIH), a rare cause of nephrocalcinosis, results from genetic defects in CYP24A1 or SLC34A1. Mutations in CYP24A1, which encodes 25-hydroxyvitamin D 24-hydroxylase, disrupt active vitamin D degradation. IIH clinically manifests as failure to thrive and hypercalcemia within the first year of life and usually remits spontaneously. Herein, we present a case of IIH wih CYP24A1 mutations. An 11-month-old girl visited our hospital with incidental hypercalcemia. She showed failure to thrive, and her oral intake had decreased over time since the age of 6 months. Her initial serum parathyroid hormone level was low, 25-OH vitamin D and 1,25(OH)2 vitamin D levels were normal, and renal ultrasonography showed bilateral nephrocalcinosis. Whole-exome sequencing revealed compound heterozygous variants in CYP24A1 (NM_000782.4:c.376C>T [p.Pro126Ser] and c.1310C>A [p.Pro437His]). Although her hypercalcemia and poor oral intake spontaneously resolved in approximately 8 months, we suggested that her nephrocalcinosis and renal function be regularly checked in consideration of potential asymptomatic renal damage. Hypercalcemia caused by IIH should be suspected in infants with severe nephrocalcinosis, especially when presenting with failure to thrive.

A 24-GHz Wide-IF Down-Conversion Mixer Based on 0.13-μm RFCMOS Technology (0.13-μm RFCMOS 공정 기반 24-GHz 광대역 하향 변환 혼합기)

  • Kim, Dong-Hyun;Rieh, Jae-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.11
    • /
    • pp.1235-1239
    • /
    • 2010
  • In this work, a wideband technique has been proposed that improves the IF bandwidth of mixers and a 24-GHz down-conversion mixer employing the proposed technique has been designed and fabricated based on 0.13-${\mu}m$ RFCMOS technology. The mixer showed the conversion gain of $2.7{\pm}1.5$ dB from DC to 5.25 GHz IF for a fixed LO frequency of 24 GHz. Measured P-1dB and LO-RF isolation was -8.7 dBm and 21 dB, respectively. The mixer draws DC current of 10.6 mA from 1.3 V supply.

Fabrication of Low Cost Radar Antennas using Two Receiving Antennas (두 개의 수신안테나를 이용한 저가 레이더용 안테나 제작)

  • Hyeon-Cheol Ki
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.97-102
    • /
    • 2023
  • In this paper, we fabricated transmitting and receiving antennas to realize the low cost radar using two receiving antennas and investigated their characteristics. The antennas are designed with MPA(Microstrip Patch Array) structure for the beam concentration in horizon direction and low cost and used Taylor array pattern synthesis to suppress sidelobes. As a results of measurement in the 24GHz ISM band(24.0-24.25GHz), our using band, antenna gains are placed between 15.2 dBi and 16.26 dBi which are satisfied with the design specification of higher than 15dBi and lower than 17dBi. The sidelobes are -13.15 dBc, -13.1 dBc and -12.8 dBc at the operating frequencies of 24.0 GHz, 24.125 GHz and 24.25 GHz repectively, which are satisfied with the specification of lower than -10 dBc.

A Study on the effects of CSRR-metamaterial on Microstrip Comb-line Array Antennas (마이크로스트립 콤 어레이 안테나에서 CSRR-메타물질의 영향에 관한 연구)

  • Ki, Hyeon-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.187-192
    • /
    • 2017
  • We investigated the effects of the CSRR-metamaterial on microstrip comb-line array antennas. Microstrip comb-line array antennas was designed with 12 radiators, gain of 16.09dBi and bandwidth of 0.24GHz in the 24GHz ISM band. The designed antenna had radiation beam perpendicular to the antenna plane, co-polarization gain of 16.09dBi and cross-polarization gain of -10.86dBi. the CSRR-metamaterial increased largely the impedance bandwidth of the antenna from 0.24GHz to 3.6GHz. however as co-polarization gain became 10.08dBi and cross-polarization gain became 14.1dBi, co-polarization was mixed with cross-polarization. And the antenna gain lowered by 1.99dB. On the investigation of the dependence on the split-direction of the CSRR rings, it showed nearly the same characteristics for up-splitted ring used case and down-splitted ring used case. However in the case of arranging up-splitted ring and down-splitted ring in alternation, co-polarization gain decreased to -1.29dBi and cross-polarization gain increased to 13.9dBi, which meant the wave was transited to cross-polarization majority wave.

A 24 GHz I/Q LO Generator for Heartbeat Measurement Radar System (심장박동 측정 레이더를 위한 24GHz I/Q LO 발생기)

  • Yang, Hee-Sung;Lee, Ockgoo;Nam, Ilku
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.66-70
    • /
    • 2016
  • This paper presents an 24 GHz I/Q LO generator for a heartbeat measurement radar system. In order to improve the mismatch performance between I and Q LO signals against process variation, a 24 GHz I/Q LO generator employing a low-pass phase shifter and a high-pass phase shifter composed of inductors and capacitors is proposed. The proposed 24 GHz I/Q LO generator consists of an LO buffer, a low-pass phase shifter and a high-pass phase shifter. It was designed using a 65 nm CMOS technology and draws 8 mA from a 1 V supply voltage. The proposed 24 GHz I/Q LO generator shows a gain of 7.5 dB, a noise figure of 2.3 dB, 0.1 dB gain mismatch and $4.3^{\circ}$ phase mismatch between I and Q-path against process and temperature variations for the operating frequencies from 24.05 GHz to 24.25 GHz.

Design of a 24 GHz Power Amplifier Using 65-nm CMOS Technology (65-nm CMOS 공정을 이용한 24 GHz 전력증폭기 설계)

  • Seo, Dong-In;Kim, Jun-Seong;Cui, Chenglin;Kim, Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.10
    • /
    • pp.941-944
    • /
    • 2016
  • This paper proposes 24 GHz power amplifier for automotive collision avoidance and surveillance short range radar using Samsung 65-nm CMOS process. The proposed circuit has a 2-stage differential power amplifier which includes common source structure and transformer for single to differential conversion, impedance matching, and power combining. The measurement results show 15.5 dB maximum voltage gain and 3.6 GHz 3 dB bandwidth. The measured maximum output power is 13.1 dBm, input $P1_{dB}$ is -4.72 dBm, output $P1_{dB}$ is 9.78 dBm, and maximum power efficiency is 17.7 %. The power amplifier consumes 74 mW DC power from 1.2 V supply voltage.

Design of 24-GHz 1Tx 2Rx FMCW Transceiver (24 GHz 1Tx 2Rx FMCW 송수신기 설계)

  • Kim, Tae-Hyun;Kwon, Oh-Yun;Kim, Jun-Seong;Park, Jae-Hyun;Kim, Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.758-765
    • /
    • 2018
  • This paper presents a 24-GHz frequency-modulated continuous wave(FMCW) radar transceiver with two Rx and one Tx channels in 65-nm complementary metal-oxide-semiconductor(CMOS) process and implemented it on a radar system using the developed transceiver chip. The transceiver chip includes a $14{\times}$ frequency multiplier, low-noise amplifier, down-conversion mixer, and power amplifier(PA). The transmitter achieves >10 dBm output power from 23.8 to 24.36 GHz and the phase noise is -97.3 GHz/Hz at a 1-MHz offset. The receiver achieves 25.2 dB conversion gain and output $P_{1dB}$ of -31.7 dBm. The transceiver consumes 295 mW of power and occupies an area of $1.63{\times}1.6mm^2$. The radar system is fabricated on a low-loss Duroid printed circuit board(PCB) stacked on the low-cost FR4 PCBs. The chip and antenna are placed on the Duroid PCB with interconnects and bias, gain blocks and FMCW signal-generating circuitry are mounted on the FR4 PCB. The transmit antenna is a $4{\times}4$ patch array with 14.76 dBi gain and receiving antennas are two $4{\times}2$ patch antennas with a gain of 11.77 dBi. The operation of the radar is evaluated and confirmed by detecting the range and azimuthal angle of the corner reflectors.

Effects of Photoperiod Manipulation on Growth Performance and Hematological Responses of Juvenile Caspian Roach Rutilus rutilus caspicus

  • Shahkar, Erfan;Kim, Dae-Jung;Mohseni, Mahmoud;Khara, Hossein;Yun, Hyeonho;Bai, Sungchul C.
    • Fisheries and Aquatic Sciences
    • /
    • v.18 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • A 8-week trial was conducted to evaluate the effects of photoperiod manipulation on the growth performance and hematological parameters of juvenile Caspian roach, Rutilus rutilus caspicus (average weight $1.46{\pm}0.12g$ mean${\pm}$SD) reared under five photoperiods (24 h Light, 24L; 18 h Light & 6 h Dark, 18L:6D; 12 h Light & 12 h Dark, 12L:12D; 6 h Light & 18 h Dark, 6L:18D; 24 h Dark, 24D) with constant light intensity 1,500 lx on the water surface. Triplicate of 20 fish were allocated into each of 15 fiberglass tanks of 50 L capacity and they were fed three times per day with the commercial feed (SFK, Co., Sari - Iran) contains 50.0% protein and 10.5% lipid. At the end of experimental period, final body weight, weight gain and specific growth rates of fish exposed to 24L were significantly higher than those of fish exposed to 12L:12D, 6L:18D and 24D (P < 0.05). Red blood cell and hemoglobin of fish exposed to 24L were significantly higher than those of fish exposed to 24D. No significant difference observed in hematocrit, white blood cell and plasma glucose among the different treatments groups. Therefore, these results demonstrated that the growth performance of juvenile Caspian roach can be significantly stimulated by using 24L and 18L:6D photoperiods without any measurable significant stress response such as plasma glucose concentration.