발전용 발전기 여자설비의 오일 오염방지 (Prevention of Oil Contamination in the Excitation System of a Power Plant Generator)

  • 최재규;유호선;문승재
    • 플랜트 저널
    • /
    • 제7권2호
    • /
    • pp.30-38
    • /
    • 2011
  • The purpose of this paper is to review the understanding of pollution causes in the excitation system and how to solve the problem. The cause of the problem was in-leakage of bearing lubricant oil through the gap between rotor and outer in the air deflector, which was triggered by a negative pressure with respect to the operation of a collector ring fan in the collector house. In order to prevent exciting current transmission equipment pollutant, the reduction of the negative gage pressure of the inside of collector house is required. The protection in-leakage of bearing lubricant oil through the gap between rotor and outer of the air deflector are necessary. The reduction of the inside diameter of air deflector and the expansion of inlet filter of collector house are inevitable.

  • PDF

발전용 증기터빈의 Oil Deflector부 탄화물 퇴적에 의한 간헐적 고진동 현상 규명 (Examination of the Intermittent High Vibration by the Accumulated Carbide at Oil Deflector of a Steam Turbine for Power Plant)

  • 양승헌;박철현;김재실;하현천
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.190-195
    • /
    • 2002
  • The intermittent high vibration has been occurred one or two times a day for a 500MW large steam turbine during 5 months. This abnormal vibration was caused by the rubbing between the rotor and the carbide accumulated on the seal tooth of oil deflector. It was found that the accumulated carbide was insulation material installed on the HIP casing from the examination of the chemical composition. Also, this paper presents the mechanism of the intermittent high vibration and the proper method to eliminate this vibration problem. This result would be good practice to find the solution of similar high vibration in the steam turbines for power plant as well as industrial rotating machineries.

  • PDF

양자교환된 LiNbO$_{3}$에서 박막도파형 음향광학 광변위기 (Thin film acoustooptic beam deflector in proton-exchanged LiNbO$_{3}$)

  • 김성국;백운석;김광택;정성갑;송재원
    • 전자공학회논문지A
    • /
    • 제32A권7호
    • /
    • pp.94-103
    • /
    • 1995
  • Thin film acoustooptic beam deflector in proton-exchanged Y-cut LiNbO$_{3}$ was fabricated and measured. The planar waveguide was fabricated by using the proton-exchanged and annealing method in Y0cut LiNbO$_{3}$. Interdigital transducer for SAW(surface acoustic wave) was made by the laser lithography. Using above method, the thin film acoustooptic beam deflector was constructed. Its SAW wavelength was 20.mu.m at 174MHz center frequency. The interaction length between guided optical wave and SAW was 2.16mm. The measured 3dB bandwidth was 17MHz using He-Ne laser. And 70% diffraction efficiency was obtained at 970mW RF driving power.

  • PDF

1단용 액체로켓엔진 후류의 물분사 방식에 따른 수치적 냉각 성능 평가 (Numerical Evaluation of Cooling Performance of 1st Stage Liquid Rocket Engine Plume by Water Injection Types)

  • 문윤완;김승한;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.739-740
    • /
    • 2010
  • 1단용 액체로켓엔진 후류 때문에 발생하는 유도로의 열적 부하를 감소시키기 위한 방법 중 물분사 방식의 효과적인 냉각 성능을 고찰하기 위해 두 가지 방법과 다양한 물분사 조건에 대해 수치적 계산을 수행하였다. 중앙분사 방식이 측면분사 방식보다 보다 효과적으로 후류를 냉각시켜 유도로의 열적부하를 감소시킴을 알 수 있었다.

  • PDF

초소형 전자칼럼의 대면적 주사 적정조건 (The Optimal Condition for Scanning Large Area with a Micro-electron-column)

  • 박성순;김호섭;장원권
    • 한국전기전자재료학회논문지
    • /
    • 제20권6호
    • /
    • pp.481-486
    • /
    • 2007
  • In large area scanning with a micro-electron-column, the operating condition for the best resolution was investigated in factors of working distance and field of view. The resolution of a test sample was dependent on electron beam energy and scanning field size. The best resolution with single deflector was obtained at 300 V and 30 mm in the electron emitting tip voltage and a working distance, respectively. The scanning area at that condition was $13.9{\times}13.9mm^2$, linearly increased with the working distance. Double deflector was employed for larger scanning size without increasing working distance, but showed only 1.7 times larger than that of single deflector, and the resolution was inverse proportional to the scanning size.

발전용 증기터빈의 Oil Deflector부 탄화물 퇴적에 의한 주기적 고진동 현상 규명 (Examination of the Periodic High Vibration by the Accumulated Carbide at Oil Deflector of a Steam Turbine for Power Plant)

  • 양승헌;박철현;김재실;하현천
    • 한국소음진동공학회논문집
    • /
    • 제12권11호
    • /
    • pp.897-903
    • /
    • 2002
  • The periodic high vibration has been occurred one or two times a day for a 500 MW large steam turbine during 5 months. This abnormal vibration was caused by the rubbing between the rotor and the carbide accumulated on the seal tooth of oil deflector. It was found that the accumulated carbide was insulation material installed on the HIP casing from the examination of the chemical composition. Also, this paper presents the mechanism of the periodic high vibration and the proper method to eliminate this vibration problem. This result would be good practice to find the solution of similar high vibration in the steam turbines for power plant as well as industrial rotating machineries.

정전형 8중극 비점수차 보정기가 내장된 극초소형 마이크로컬럼의 구조 설계 연구 (Study on the Structural Design of an Ultra-miniaturized Microcolumn with a Built-in Electrostatic Octupole Stigmator)

  • 오태식
    • 반도체디스플레이기술학회지
    • /
    • 제22권3호
    • /
    • pp.52-61
    • /
    • 2023
  • We designed a novel ultra-miniaturized microcolumn structure having an stigmator to significantly improve throughput per unit time, which is the biggest disadvantage of microcolumns. We adopted the structure of the stigmator in the form of an electrostatic octupole electrode, and used an electrostatic quadrupole deflector with a relatively simple structure considering the increase in wiring due to the introduction of the stigmator. We have dramatically reduced the effect of astigmatism that occurs when the electron beam probe is scanned to the periphery of the target by introducing the stigmator between the control electrode and the deflector. As our numerical analysis simulation results, the field of view obtained as a result of this study is about 46.3% improved compared to our previous study, and the electron beam probe size of less than 10 nm was achieved in the entire field of view.

  • PDF

Holeburning 광메모리용 가변파장 레이저 시스템의 구현에 관한연구 (A study on the implementation of a tunable laser system for holebuning optical memory)

  • 김민지
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1998년도 제15회 광학 및 양자전자 학술발표회 논문집
    • /
    • pp.170-171
    • /
    • 1998
  • Here are proposed the tunable laser for optical memory which uses the acousto-optic deflector. This laser includes the acousto-optic deflector in the Littrow mount configuration so that we may control the beam deflection by means of the induced RF. Consequently, we can achieve the higher speed and accuracy to compare with the Littrow monut configuration only.

  • PDF

EDISON-CFD를 활용한 대형 트럭 디플렉터 형상에 따른 항력 감소 효과에 관한 연구

  • 박상현
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제6회(2016년)
    • /
    • pp.1-3
    • /
    • 2016
  • 대형 화물 트럭(heavy-duty truck)은 화물 적재에 용이하지만, 공기역학적으로 불리한 형상을 가진다. 이러한 단점을 극복하고자 대형 화물 트럭에는 공기저항력(aerodynamic drag)을 줄일 수 있는 여러 가지 장치가 달려있다. 본 논문에서는 디플렉터(deflector) 형상이 항력 감소에 어떠한 영향을 주며, 평판 형태와 굴곡진 형태의 디플렉터 형상에 대한 항력 계수 비교를 EDISON-CFD를 활용하여 비교하였다. 해석 결과, 측풍(side-wind)의 영향을 무시하며 차량 속도 95 km/h로 등속을 유지하는 조건에서 평판 형태의 Model 1과 바깥으로 굴곡진 Model 2에서 전체 항력 계수가 낮게 나타났다.

  • PDF

싸이폰식 여수토의 진공촉진에 대한 연구 (A Study on Accalerated Vocous Condition in Siphon Spillway)

  • 김시원
    • 한국농공학회지
    • /
    • 제6권2호
    • /
    • pp.816-825
    • /
    • 1964
  • 1. Outline: The flow of the siphon spillway is very intricate and affected by vacuous condition. It is an intresting problem to make vacuum rapidly in_siphon, i.e, to provoke the perfect siphonaoge with the lowest water-level of overflow. The hydraulic experiments of siphon spillway have practiced at the Masan Lake, Haenam, the province of Junnam and gained rational and economical results which cannot be odtained by calculation. 2. Experiment: The model scale was a half of that of the prototype. 3. Results and discussion: In the experiments of 14 runs, washing, overflow water level, outlet, water level of cushion, phenomenon of water flying and water pressure of every part, etc. were studied. a) The relation of overflow water-level at siphon inlet and deflector When the elevation of the deflector is 10. 65m and the form of deflector O.4m long is the hypotenuse of an $45^{\circ}$ isosceles triangle, the over flow water-level is the minimum, i. e. the siphonage was excellent. There is no effect by the rising of overflow water-Ievel between 11.95m to 1O.65m of deflector elevation (in the first plan, it is 11.05m). But the overflow water-level rises remarkably in the outside region of the above limits. b) The relation of overflow water-level, the length of cushion and standard height of the base. The reduction of the length of cushion brings the rising of overflow waterlevel, and the rising of the standard height of the base brings the rising of overflow water level. For the long cushion length and low standard height of the base, it cannot be expeted to have the falling of overflow water-level. The most satisfactory data were obtained at 5.20m of the base standard height and 6.1m of the length of cushion. The first vah,le planned was 5.70 m and 4.30m.

  • PDF