• 제목/요약/키워드: Dental impression technique

검색결과 71건 처리시간 0.026초

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.

A simple technique for impression taking of teeth and functionally generated paths

  • Yamamoto, Takatsugu;Sato, Yohei;Watanabe, Hidehiko;Punj, Amit;Abe, Minoru;Momoi, Yasuko;Ohkubo, Chikahiro
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.9.1-9.6
    • /
    • 2018
  • The objective of this case report is to introduce a simple technique for simultaneously taking a closed-mouth impression and functionally generated path (FGP) for a full coverage crown restoration. A monolithic zirconia crown was the restoration of choice. An alginate impression of the abutment tooth was taken to fabricate a custom-made closed-mouth impression tray covering the abutment tooth and the adjacent teeth. The tray had an FGP table and an abutment tray in cameo and intaglio surfaces, respectively. The impression was taken with silicone impression material after adjusting the abutment tray and inscribing the FGP using self-curing acrylic resins. Plaster casts were made from the impression, and a zirconia crown was fabricated. The crown was cemented to the abutment tooth with minimal adjustments. This simple technique resulted in a well-fitting crown that accounted for mandibular movements. Using the custom closed-mouth impression tray incorporating an FGP table simultaneously aids in fabricating an accurately fitting restoration that incorporates harmonious mandibular movements using a single impression capture.

폐구인상채득법을 이용한 임플란트 인상채득 증례 (Implant impression using closed mouth impression technique: a case report)

  • 김소연;김주현;정경화;전혜미;강은숙;윤미정
    • 구강회복응용과학지
    • /
    • 제33권3호
    • /
    • pp.223-229
    • /
    • 2017
  • 단일 치아의 인상채득을 위해서는 바이트 트레이를 이용한 폐구인상법이 선호된다. 그러나 임플란트 인상채득을 위해서는 단일치와 다수치 구분 없이 편악 트레이를 이용한 개구인상법이 주로 사용되고 있다. 바이트 트레이를 이용하는 폐구인상법은 시간이 절약되고 재료가 적게 들며, 모형의 교합기 부착 시 상하악 악간 위치 관계 오차 발생 확률이 적다. 본 증례에서는 2 가지 종류의 폐구인상용 코핑을 이용해 바이트 트레이로 인상채득 후 단일 임플란트 고정성 보철물을 제작함에 있어 만족할 만한 결과를 얻어 보고하고자 한다.

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

  • Pastoret, Marie-Helene;Krastl, Gabriel;Buhler, Julia;Weiger, Roland;Zitzmann, Nicola Ursula
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.287-293
    • /
    • 2017
  • PURPOSE. To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS. A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (${\pm}SD$). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS. Dimensional changes compared to reference values varied between -74.01 and $32.57{\mu}m$ (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION. The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth.

Effectiveness of the novel impression tray "cleftray" for infants with cleft lip and palate: a randomized controlled clinical trial

  • Kalaskar, Ritesh;Bhaje, Priyanka;Balasubramanian, Shruti;Kalaskar, Ashita
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권2호
    • /
    • pp.82-90
    • /
    • 2021
  • Objectives: Cleft lip and palate (CLP) is one of the most common congenital deformities with worldwide prevalence. It causes a range of issues for infants that mainly involve difficulty in feeding due to abnormal oronasal communication. For this purpose, feeding plates are provided to infants to act as an artificial palate to aid in feeding. The most crucial procedure in fabrication of a feeding plate is creation of the impression using the traditional finger technique or impression trays. This preliminary research aims to compare the effectiveness of novel impression trays with that of the traditional finger technique for recording impressions of infants with CLP. Materials and Methods: This randomized controlled trial was conducted among 30 infants who were divided into two groups based on the method of obtaining impressions: Group I, finger technique; Group II, specialized acrylic tray (cleftray). Results: Use of cleftray required less impression time, a reduced amount of material, no incidence of cyanosis/choking in infants, and lower anxiety among doctors compared to the traditional method. Additionally, there was no distortion of cleft impressions, recorded maxillary tuberosity, or other fine details. Therefore, the novel impression tray (cleftray) exhibited superior outcomes in all the parameters compared to the finger technique. Conclusion: Within the limitations of this study, we conclude that impression trays are superior to the traditional finger, spoon, or ice cream stick methods of creating impressions of CLP. However, it is necessary to conduct more clinical trials on a larger population based on other parameters to compare the effectiveness of the two techniques to draw definitive conclusions.

디지털 방식을 이용하여 제작한 전부 지르코니아 수복물의 변연 적합도 평가 (Evaluation of marginal fit of monolithic zirconia restoration by digital impression)

  • 윤미정;김소연;강은숙
    • 대한치과의사협회지
    • /
    • 제56권7호
    • /
    • pp.366-374
    • /
    • 2018
  • Purpose : The purpose of this study was to compare the marginal fit of monolithic zirconia restorations fabricated form the conventional and the digital impression technique. Materials and methods : Ten patients were restored with monolithic zirconia restorations fabricated from the digital and the conventional impression technique. Before definitive insertion, silicone replicas were produced from all twenty crowns. The silicone replicas were cut in three sections; each section was evaluated at two points. The measurement was carried out by using a measuring microscope (Olympus BX 51) and I-Solution. Data from the silicone replica scores were analyzed by Shapiro-Wilk test for normal distribution and the t-test for equality of two population's mean. All tests were performed with ${\alpha}-level$ of 0.05. Results : The average marginal gaps of monolithic zirconia restorations were $133.81{\pm}36.46{\mu}m$ for the conventional impression technique, $90.07{\pm}9.47{\mu}m$ for the digital impression technique. No statistical differences were found between the two impression techniques Conclusion : Both prostheses presented clinically acceptable results with comparing the marginal fit.

  • PDF

Alternative impression technique for multiple abutments in difficult case to control

  • Jung, Bock-Young;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권1호
    • /
    • pp.1-3
    • /
    • 2010
  • BACKGROUND. Even though excellent impression materials are now available for making accurate replication for hard and soft tissue, the numerous dentists have faced lots of obstacles in making simultaneous impressions of multiple abutments. CASE DESCRIPTION. This article describes a modified method of tray fabrication using auto-polymerizing acrylic resin and impression technique for multiple prepared teeth in cases with limitations and difficulties in taking dental impressions. CLINICAL IMPLICATION. This segmental tray technique has several advantages, including higher impression quality, fewer impressions, and being more comfortable for the patient and less stressful for the clinician.

편측후방연장 국소의치에서 인상채득 방법과 클라스프 설계에 따른 지대치의 응력분석에 관한 연구 (STRESS ANALYSIS OF ABUTMENT FOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE BY CLASP DESIGN AND IMPRESSION METHOD)

  • 안희영;김광준;조혜원;진태호
    • 대한치과보철학회지
    • /
    • 제39권5호
    • /
    • pp.547-555
    • /
    • 2001
  • This study was performed tn investigate the effects of impression method and design of the retainer on the stress of abutment tooth in distal extension RPD. Three different types of direct retainer such as Akers clasp, RPI clasp, and wrought wire clasp were designed. Stress on the abutment tooth was measured and analyzed with strain gauge method. Impressions were anatomic impression technique and functional impression technique. The following conclusions were drawn from this study. 1. The stress at the abutment tooth on all RPD was decreased in functional impression except RPI clasp retained RPD. 2 The stress at the abutment tooth on RPI clasp retained RPD was the most smallest in anatomic Impression. 3. While load is increase the stress at the abutment tooth was increased, but the change of stress at the buccal side of abutment tooth was not too much in functional impression.

  • PDF

Putty 인상재를 채용한 PVS 인상채득 기법에 관한 연구 (A STUDY OF IMPRESSION TECHNIQUE USING PUTTY MATERIAL OF PVS IMPRESSION MATERIAL)

  • 전영찬;나경수
    • 대한치과보철학회지
    • /
    • 제35권3호
    • /
    • pp.535-543
    • /
    • 1997
  • In order to compare the accuracy of impression technique using the addition silicone putty and improved heavy body material, impression were taken for the natural 6 maxillary anterior teeth, and for the metal mast model that has full arch shape with 4 cylindrical abutment teeth. Marginal gingiva was retracted by routine method using retraction cord, and two techniques were tried to compare the length of impression materials in the gingival sulcus. This was aimed to see the effect of viscosity and hydraulic pressure of impression materials for the subgingival impression. Impressions for the full arch-shaped metal master model were taken to compare the linear stability of the different impression materials and their related techniques. The conclusions were as belows : 1. The one-step impression technique showed longer extension of impression material in gingival sulcus than two-step impression technique. 2. High viscosity and hydraulic pressure of impression material were useful to take subgingival impression. 3. There was no statistically significant difference for the two-dimensional accuracy of impression technique, but two-step technique showed better trend than one-step technique.

  • PDF

Open and Closed Mouth Impression Techniques for Mandibular Implant Overdenture: Two Cases Report

  • Ha-Jin, Yoon;Jung-Yoon, Bae
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.152-161
    • /
    • 2022
  • Mandibular implant overdenture is a good treatment option for complete edentulous patients with restoring removable prosthesis. Mandibular implant overdenture with two implants and locator attachments is widely used. It is tissue-supported overdenture that is made with the concept of conventional complete denture fabrication. There are two patients who provided impressions by open mouth technique and closed mouth technique in each case. In both cases, mandibular implant overdentures were restored with functionally and aesthetically satisfying results.