• 제목/요약/키워드: Desulfurization system

검색결과 91건 처리시간 0.03초

$CaCo_3-CO_2-NH_3$계에서의 배연탈황 특성 (Characteristics of the Flue Gas Desulfurization in $CaCo_3-CO_2-NH_3$ System)

  • 모세영;이경재;장홍기;손종렬
    • 환경위생공학
    • /
    • 제14권2호
    • /
    • pp.84-89
    • /
    • 1999
  • This experiment was performed to develop the new desulfurization process which can eliminate the possibility of generation of the secondary pollutants by regenerating the limestone from the sulfite/sulfate slurry generated from the wet lime/limestone flue gas desulfurization process by treating it with the ammonium hydroxide and carbon dioxide and using it again. In the experiments, regent grade calcium carbonate was dissolved to obtain the 200ml of sample slurry of the concentration of 2.0~0.4 weight percent. After three times of regeneration and desulfurization process, the coefficients of regeneration and desulfurization efficiencies are calculated/measured. The obtained results are that the coefficients of generation of the first. second, and third regenerated calcium carbonate were 90.88, 92.13, and 91.50%, respectively; and the desulfurization efficiencies of those are 93.4, 94.2 and 93.0%, respectively.

  • PDF

The Utilization of Waste Seashells for $H_{2}S$ Removal

  • Kim, Young-Sik;Suh, Jeong-Min;Jang, Sung-Ho
    • 한국환경보건학회지
    • /
    • 제31권6호
    • /
    • pp.483-488
    • /
    • 2005
  • The waste seashells were used for the removal of hydrogen sulfide from a hot gas stream. The sulphidation of waste seashells with $H_{2}$S was studied in a thermogravimetric analyzer at temperature between 600 and $800^{circ}C$. The desulfurization performance of the waste seashell sorbents was experimentally tested in a fixed bed reactor system. Sulfidation experiments performed under reaction conditions similar to those at the exit of a coal gasifier showed that preparation procedure and technique, the type and the amount of seashell, and the size of the seashell affect the $H_{2}$S removal capacity of the sorbents. The pore structure of fresh and sulfided seashell sorbents was analyzed using mercury porosimetry, nitrogen adsorption, and scanning electron microscopy (SEM). Measurements of the reaction of $H_{2}$S with waste seashells show that particles smaller than 0.631 mm can achieve high conversion to CaS. According to TGA and fixed bed reactor results, temperature had influenced on $H_{2}$S removal efficiency. As desulfurization temperature increased, desulfurization efficiency increased. Also, maximum desulfurization efficiency was observed at $800^{circ}C$. Desulfurization was related to calcinations temperature.

석탄화력발전소 현장의 석탄연소 배가스 고도처리용 건식 분류층 반응 실증장치에서의 $SO_2$ 제거성능 특성 (Removal Characteristics of $SO_2$ in the Coal Combustion Flue Gas Treatment Convergence System)

  • 전성민;박형상;박영옥
    • 한국입자에어로졸학회지
    • /
    • 제9권4호
    • /
    • pp.239-246
    • /
    • 2013
  • The purpose of this study is to determine the feasibility of dry-type desulfurization process for actual application to coal-fired power plant. We used actual exhaust gas from Facility Y, Plant #2 to fabricate a demo-scale testing device to attempt to improve the efficiency of desulfurization. A spout-bed circulating dry scrubber convergence system connecting turbo reactor with bag filter was devised, then analyzed for performance characteristics of $SO_2$ removal for Ca/S mole ratio, superficial gas velocity, and ammonia injection, and for secondary reaction characteristics of the non-reactive sorbent at the bag filter. As a result, the installation of spout-bed circulating dry scrubber convergence system showed better economy and efficiency for removing sulfur than the existing wet/semidry-type desulfurization process. In addition, the best efficiency for desulfurization occurred when connected to the bag filter, with differential pressure maintained at 150 $mmH_2O$.

국산 개발 배연탈황 설비의 제어루프 구현 (An implementation Of Control Loop For Domestic Flue Gas Desulfurization System)

  • 이찬주;김응석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.825-827
    • /
    • 1998
  • Air pollution is one of the most important global issues of the environmental concerns. Some advanced foreign countries have developed the air pollution control technology. KEPCO has been researching on the air pollution control technology and developed the FGD(Flue Gas Desulfurization) system for 200MW thermal power plant. In this paper, we describe the major control loops implemented to the domestic FGD system. The major control loops are to be classified into booster fan control, absorber PH control and limestone density control. The control loops were applied to the actual desulfurization processes and proved to their performance.

  • PDF

습식 배연탈황설비용 습분제거기 포집효율 평가 (Collection Efficiency of a Mist Eliminator for Wet Flue Gas Desulfurization)

  • 김문원;육세진;류태우
    • 한국입자에어로졸학회지
    • /
    • 제14권3호
    • /
    • pp.73-80
    • /
    • 2018
  • Recently, there has been much research on the effect of ultrafine dust on human body with increasing interest in the ultrafine dust. In the Republic of Korea, there are many old thermal power plants, and the amount of ultrafine dust emitted from the thermal power plants is reported to be about 14% of the total amount of domestic fine dust. Therefore, the amount of fine dust from the flue gas desulfurization facility in the thermal power plant needs be reduced. In this study, we made an experimental setup to simulate a flue gas desulfurization facility and analyzed the physical characteristics of the particles passing through a mist eliminator. Experiments were carried out to investigate the collection efficiency of the mist eliminator by using the Arizona Test Dust in a dry environment, and then spraying limestone slurry into the flue gas desulfurization system equipped with the mist eliminator to examine the size and morphology of limestone particles upstream and downstream of the mist eliminator. Cut-off size of the mist eliminator was formed at about $6{\mu}m$. The result of this study is expected to be helpful for designing an electrostatic precipitator for removing particles passing through the mist eliminator.

탈황 설비용 유기 라이너의 평가 (Evaluation of the Organic Linings at Gas Desulfurization System)

  • 송요승;권현옥;조남인
    • 한국정밀공학회지
    • /
    • 제29권11호
    • /
    • pp.1178-1182
    • /
    • 2012
  • The organic linings at flue gas desulfurization systems (FGD system) in power plant have the excellent chemical properties but, lose the anticorrosive properties according to the aging with environment conditions. The properties of the organic linings depend on the manufacturing company. Therefore, the basic properties of organic linings for the preestimate of life time should be examined by conducting the aging and the bond strength test according to temperature. The pre-aging samples were compared with the post-aging samples. The temperature conditions of the aging process were 70, 150 and $200^{\circ}C$. The bond strength was calculated and the cross sections of fracture surface were examined by optical microscope and SEM. The $T_g$ was examined by DSC, DTA and TGA.

반건식 세정기의 산성가스 제거성능에 관한 실험적 연구 (An Experimental Approach to Evaluate the Desulfurization Yield in Spray Drying Sorber)

  • 양현모;김상수
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.589-598
    • /
    • 2000
  • A pilot-scale Spray Drying Sorber (SDS) system was set up to evaluate the effect of spray characteristics on the desulfurization yield. The size distribution and the Sauter Mean Diameters of slurry droplets were measured in advance using the optical size measurement system, Malvern 2600. The desulfurization yield of the drying chamber by size was measured for the conditions of inlet gas and spray injection. As a reagent, 10% limestone slurry of $Ca(OH)_2$ was treated with flue gas containing $SO_2$, and the combustion gas analyzer and gas detectors were attached to measure the $SO_2$ concentration. With a flow rate of 144 Nm3/h and a temperature range of $200{\sim}300^{\circ}C$, the experiments were performed for the Stoichiometric Ratio (SR) of 1.0 to 3.0 and droplet mean diameter of 6.5 to $34.3{\mu}m$. In case of smaller spray droplets, the desulfurization efficiency improved due to the increase of total droplet surface area, while the reduction in evaporation time reduced the contact time between the droplets and $SO_2$ gas. In some typical region of droplet diameter, this negative effect, reduction of contact time, became dominant and the desulfurization yield decreases the desulfurization yield in spite of the expansion in absorption area. These results revealed that there exists the optimal size of spray droplets for a given state, which is determined by the compromise between the total surface area of slurry droplets and the evaporation time of droplets. The measurements also indicated that the inlet temperature of flue gas changes the optimal injection condition by varying the driving force for evaporation. The results confirm that the effect of the evaporation time of slurry droplets should be considered in analyzing the desulfurization yield as well as the total surface area, for it is a significant aspect of the correlation with the capabilities of $SO_2$ absorption in wet droplets. In conclusion, the optimal condition of spray can be determined based on these results, which might be applied to design or scale-up of SDS system.

1,000 MW 석탄화력발전소 대기환경오염물질 제거효율 향상을 위한 탈황설비 성능개선 (Enhancement of Desulfurization System Efficiency in 1,000 MW Coal-Fired Power Plants)

  • 이영수;문승재
    • 플랜트 저널
    • /
    • 제17권2호
    • /
    • pp.32-41
    • /
    • 2021
  • 최근 미세먼지 등 대기환경 문제가 국가적 이슈로 급부상 하고있는 추세이며 특히 석탄화력발전소에 대한 강도높은 환경규제치가 적용되고 있는 실정이다. 본 연구는 석탄화력발전소 주요 대기오염 배출물질인 황산화물과 먼지 제거를 위한 탈황설비 성능개선 사례에 대해 소개하고 있으며 현재 운영중인 1,000 MW 발전소의 성능개선을 위한 네가지 Case Study를 수행하고 공사를 하였다. 탈황설비 흡수탑 개조를 통해 액기비를 증대시켰으며 산화공기 유량을 증대시켜 기액 반응을 촉진하였다. 또한 가스가스히터 누설률을 개선하여 최종 탈황설비 효율을 향상시켰다. 기존 설비와 조화를 고려한 성능개선 공사를 통해 2023년부터 적용될 규제치(황산화물 25ppm, 먼지 5mg/Sm3)를 만족할 것으로 예상되며 타 화력발전소에 검토 및 적용하는데 참고될 수 있다고 기대된다.

철산화 박테리아 Thiobacillus ferrooxidans를 이용한 충전탑 반응기에서의 석탄의 생물학적 탈황 (Microbial Desulfurization of Coal by Iron-Oxidizing Bacteria Thiobacillus ferrooxidans in packed beds)

  • 류희욱
    • KSBB Journal
    • /
    • 제14권1호
    • /
    • pp.124-130
    • /
    • 1999
  • 아적장에서의 석탄의 탈황 가능성을 조사하기 위하여 Thiobacllus ferrooxidans를 이용한 탈황특성을 연구하였다. 배지의 배수를 고려할 때 야적장에서 미생물 탈황공정을 적용하기 위해서는 석탄입자 크기가 1mm 이상이어야 하고, 균일한 입자분포가 요구됨을 확인하였다. 1~2mm의 입자층과 2~4mm의 입자층에서의 약 70일 동안에 24%와 42%의 pyrite를 제거할 수 있었다. 두 석탄 입자층의 탈황속도는 각락 248mg S/kg coal.day (5,638mg S/kg pyritic-S.day)와 803mg S/kg coal.day(6,805mg S/kg pyritic-S,day)로 현탁배양의 약 15~25%로 낮았다. 석탄층에 액체배지를 순환하지 않고 단지 T.ferrooxidans의 접종만으로도 석탄의 표층부에서는 탈황이 가능하였다. 석탄을 야적장 등에 장기간 보관하는 동안에 고유황 석탄으로부터 미생물 탈황공정을 응용하여 부분적인 pyritic sulfur의 제거가 가능한 것을 알 수 있었다.

  • PDF

기계적 합금화 공정에 의한 Fe가 코팅된 Mg 탈황 분말 제조 연구 (Fabrication of Fe coated Mg Based Desulfurization Powder by Mechanical Alloying Process)

  • 송준우;;천병선;홍순직
    • 한국분말재료학회지
    • /
    • 제19권3호
    • /
    • pp.226-231
    • /
    • 2012
  • In this research, the coating behavior of Mg and Fe desulfurization powder fabricated by low energy and conventional planetary mill equipment was investigated as a function of milling time, which produces uniform Fe coated powders due to milling energy. Since high energy ball milling results in breaking the Fe coated Mg powders into coarse particles, low energy ball milling was considered appropriate for this study, and can be implemented in desulfurization industry widely. XRD and FE-SEM analyses were carried out to investigate the microstructure and distribution of the coating material. The thickness of the Fe coating layer reaches a maximum of 14 ${\mu}m$ at 20 milling hours. The BCC structures of Fe particles are deformed due to the slip system of Fe coated Mg particles.