• Title/Summary/Keyword: Diagnostic

Search Result 11,094, Processing Time 0.042 seconds

A Study of Standard Diagnostic Communications Modules for ECU Diagnostic Communications (ECU 진단통신을 위한 표준 진단통신 모듈 연구)

  • Chang, Moon-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.507-509
    • /
    • 2022
  • In order to collect vehicle internal diagnostic data, it is necessary to collect diagnostic data of ECU (Electronic Control Unit) included in various automotive parts. Diagnostic communication can be used to collect diagnostic data of ECU. In this paper, the method of collecting diagnostic data according to ECU function through standard diagnostic communication and the diagnostic communication module were analyzed. Among the standard modules of AUTOSAR, a standard for automotive electronics used by many automobile manufacturers, the diagnostic communication module was studied, and the process of diagnostic data processing through ECU was studied.

  • PDF

Extrahepatic Cholestasis in a Jindo Dog

  • Bae, Jang-Hoon;Lim, Soo-Ji;An, Ji-Young;Son, Seon-Ho;Chang, Jin-Hwa;Kwon, Young-Hang;Ahn, Se-Joon;Song, Geun-Ho;Lee, Young-Won;Choi, Ho-Jung
    • Proceedings of the Korean Society of Veterinary Clinics Conference
    • /
    • 2009.10a
    • /
    • pp.239-239
    • /
    • 2009
  • PDF

Novel reassortants of clade 2.3.4.4 H5N6 highly pathogenic avian influenza viruses possessing genetic heterogeneity in South Korea in late 2017

  • Lee, Yu-Na;Cheon, Sun-Ha;Kye, Soo-Jeong;Lee, Eun-Kyoung;Sagong, Mingeun;Heo, Gyeong-Beom;Kang, Yong-Myung;Cho, Hyun-Kyu;Kim, Yong-Joo;Kang, Hyun-Mi;Lee, Myoung-Heon;Lee, Youn-Jeong
    • Journal of Veterinary Science
    • /
    • v.19 no.6
    • /
    • pp.850-854
    • /
    • 2018
  • Novel H5N6 highly pathogenic avian influenza viruses (HPAIVs) were isolated from duck farms and migratory bird habitats in South Korea in November to December 2017. Genetic analysis demonstrated that at least two genotypes of H5N6 were generated through reassortment between clade 2.3.4.4 H5N8 HPAIVs and Eurasian low pathogenic avian influenza virus in migratory birds in late 2017, suggesting frequent reassortment of clade 2.3.4.4 H5 HPAIVs and highlighting the need for systematic surveillance in Eurasian breeding grounds.

Salmonella enterica serotype Choleraesuis infection in weaned pigs: a first clinicopathological case report from Korea

  • Kim, Jongho;Kim, Gyeongyeob;Lee, Hyunkyoung;Moon, Bo-Youn;Lee, Kichan;Byun, Jae-Won;Park, Ji-Young;Lee, Kyoung-Ki;Jeoung, Hye-Young;Ko, Mi-Kyeong;Ku, Bok-Kyung;Chung, Yun Soo;Bae, You-Chan
    • Korean Journal of Veterinary Research
    • /
    • v.62 no.2
    • /
    • pp.14.1-14.5
    • /
    • 2022
  • Salmonella enterica serotype Choleraesuis causes swine paratyphoid, with clinical findings of enterocolitis and septicemia. However, the clinicopathological features of S. Choleraesuis infections in pigs have not been reported in Korea. We describe the pathological findings of two weaned pigs with S. Choleraesuis infections, presenting with diarrhea, cough, and sudden death. Pathological examination indicated severe necrotic colitis in pig 1 and septicemic lesions in pig 2. Multidrug-resistant S. Choleraesuis was isolated from the pigs' lungs and intestinal contents. Further research is required for the surveillance of S. Choleraesuis infections in pigs and the virulence estimation in the S. Choleraesuis isolates.

Establishment of Diagnostic Criteria in the Preventive Diagnostic System for the Power Transformer (전력용 변압기 예방진단새스템의 진단기준치 실정)

  • Kweon Dong-Jin;Koo Kyo-Sun;Kwak Joo-Sik;Woo Jung-Wook;Kang Yeon-Wook
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.9
    • /
    • pp.449-456
    • /
    • 2005
  • The preventive diagnostic technique prevents transformers from power failure through giving alarm and observing transformers in service. And it helps to establish the plan for optimum maintenance of the transformer as well as to find location or cause of fault using accumulated data. Data detection and experience of the preventive diagnostic system need to establish the preventive diagnostic algorithm regarding interrelationship between detected data and deterioration of equipment. Therefore in-depth analysis about the preventive diagnosis system is required. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Techniques for component sensors of the preventive diagnosis system were settled but diagnosis algorithm, diagnostic criteria and practical use of accumulated data are not yet established. This paper, to build up the base of preventive diagnostic algorithm for the Power transformer. investigated the preventive diagnostic criteria for the power transformer.

Analysis of the Data Reliability for the Preventive Diagnostic System (예방진단시스템의 데이터 신뢰성 분석)

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Joo-Sik;Woo, Jung-Wook;Choo, Jin-Boo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.2
    • /
    • pp.94-100
    • /
    • 2005
  • Abnormal symptoms on operating conditions of power transformer are monitored by a preventive diagnostic system which prevents the sudden power failure in case of quick progress of abnormal situation. The preventive diagnostic system helps plan the proper maintenance method according to the transformer conditions via accumulated data. KEPCO has adopted the preventive diagnostic system at nine of 345kV substations since 1997. Application techniques of the diagnostic sensors were settled, but diagnostic algorithm and practical use of accumulated data are not yet established. To build up the diagnostic algorithm and effective use of the preventive diagnostic system, the reliability of the data which were accumulated in a server computer is very important. This paper describes the data analysis in the server in order to advance the reliability of the accumulated data of the preventive diagnostic system. The principles and data flows of the diagnostic sensors were analyzed, and the data discrepancy between sensors and server were calibrated.

A reliable intelligent diagnostic assistant for nuclear power plants using explainable artificial intelligence of GRU-AE, LightGBM and SHAP

  • Park, Ji Hun;Jo, Hye Seon;Lee, Sang Hyun;Oh, Sang Won;Na, Man Gyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1271-1287
    • /
    • 2022
  • When abnormal operating conditions occur in nuclear power plants, operators must identify the occurrence cause and implement the necessary mitigation measures. Accordingly, the operator must rapidly and accurately analyze the symptom requirements of more than 200 abnormal scenarios from the trends of many variables to perform diagnostic tasks and implement mitigation actions rapidly. However, the probability of human error increases owing to the characteristics of the diagnostic tasks performed by the operator. Researches regarding diagnostic tasks based on Artificial Intelligence (AI) have been conducted recently to reduce the likelihood of human errors; however, reliability issues due to the black box characteristics of AI have been pointed out. Hence, the application of eXplainable Artificial Intelligence (XAI), which can provide AI diagnostic evidence for operators, is considered. In conclusion, the XAI to solve the reliability problem of AI is included in the AI-based diagnostic algorithm. A reliable intelligent diagnostic assistant based on a merged diagnostic algorithm, in the form of an operator support system, is developed, and includes an interface to efficiently inform operators.

Fatal cryptosporidiosis in a calf (송아지에서 발생한 중증 크립토스포리듐 증 증례)

  • Baek, Kang-Hyun;Lee, Hyun-Kyoung;Lee, Kyung-Hyun;Kim, Ha-Young;Park, Jung-Won;Lee, Bo-Ram;Her, Ji-Woong;Lee, Myoung-Heon;Bae, You-Chan
    • Korean Journal of Veterinary Research
    • /
    • v.54 no.4
    • /
    • pp.257-260
    • /
    • 2014
  • A calf suffering from diarrhea was admitted to the Animal and Plant Quarantine Agency for diagnostic evaluation. Postmortem examination revealed that the mesenteric lymph node was enlarged and small intestine wall was thin. Microscopically, a large number of small round organisms were attached to the small intestine villi. Villous atrophy and proprial neutrophil infiltration were also observed. Based on modified Ziehl-Neelsen staining, electron microscopy, and ELISA results, the calf was diagnosed with fatal cryptosporidiosis.