Development of a High-performance COVID-19 Diagnostic Kit Employing Improved Antibody-quantum dot Conjugate

  • Seongsoo Kim;Hyunsoo Na;Hong-Geun Ahn;Han-Sam Park;Jaewoong Seol;Il-Hoon Cho
    • Biomedical Science Letters
    • /
    • v.29 no.4
    • /
    • pp.344-354
    • /
    • 2023
  • This study emphasizes the importance of early diagnosis and response to COVID-19, leading to the development of a rapid diagnostic kit using quantum dots. The research focuses on finely tuning bioconjugation with quantum dots to enhance the accuracy and sensitivity of COVID-19 diagnosis. We have developed a COVID-19 rapid diagnostic kit that exhibits a sensitivity more than 50 times higher than existing COVID-19 diagnostic kits. Quantum dots enable the accurate detection of COVID-19 viral antigens even at low concentrations, providing a rapid response in the early stages of infection. The COVID-19 quantum dot diagnostic kit offers quick analysis time, utilizing the quantum properties of particles to swiftly measure COVID-19 infection for immediate response and isolation measures. Additionally, this diagnostic kit allows for multiple analyses with ease, as multiple quantum dots can detect various antigens and antibodies simultaneously in a single experiment. This efficiency enhances testing, reduces sample requirements, and lowers experimental costs. The application of this diagnostic technology is anticipated in the future for early diagnosis and monitoring of other infectious diseases.

Development of Automated Rapid Influenza Diagnostic Test Method Based on Image Recognition (영상 인식 기반 신속 인플루엔자 자동 판독 기법 개발)

  • Lee, Ji Eun;Joo, Yoon Ha;Lee, Jung Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.3
    • /
    • pp.97-104
    • /
    • 2019
  • To examine different types of influenza diagnostic test kits automatically, automated rapid influenza diagnostic test method based on image recognition is proposed in this paper. First, the proposed methods classify a variety of the rapid influenza diagnostic test kit based on support vector machine that analyzes the kits' feature point. Then, to improve the accuracy of test, the proposed methods match the histogram of both the target image of influenza kit and the input image of influenza kit for minimizing the effect of environment factors, such as lighting and exposure variations. And, to minimize the effect from composition of the hand-helds devices, the proposed methods extract the feature point and match point-by-point between target image of influenza kit and input image of influenza kit. Experimental results of 124 experimental group show that the proposed methods significantly have effectiveness, which shows 90% accuracy in moderate antigen, for the preliminary examination of influenza, and provides the opportunity for taking action against influenza.

Clinical evaluation of a rapid diagnostic test kit for detection of canine coronavirus

  • Yoon, Seung-Jae;Seo, Kyoung-Won;Song, Kun-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.1
    • /
    • pp.27-31
    • /
    • 2018
  • Canine coronavirus is a single-stranded RNA virus that causes enteritis in dogs of any age. Coronaviral enteritis is seldom definitively diagnosed, since it is usually much less severe than many other types of enteritis and is self-limiting. Conventional diagnostics for the canine coronaviral enteritis such as polymerase chain reaction (PCR), virus isolation, and electron microscopic examination are inappropriate for small animal clinics due to the complicated experimental processes involved. Therefore, a commercially available lateral flow test kit based on chromatographic immunoassay techniques was tested to evaluate its performance as a first-line diagnostic test kit that could be used in clinics. The coronavirus antigen test kit detected canine coronavirus-infected dogs with 93.1% sensitivity and 97.5% specificity. The detection limit of the test kit was between $1.97{\times}10^4/mL$ and $9.85{\times}10^3/mL$ for samples with a 2-fold serial dilution from $1.25{\times}10^6\;TCID_{50}$ ($TCID_{50}$, 50% tissue culture infectious dose). Additionally, the test kit had no cross-reactivity with canine parvovirus, distemper virus, or Escherichia coli. Overall, the commercially available test kit showed good diagnostic performance in a clinical setting, with results similar to those from PCR, confirming their potential for convenient and accurate use in small animal clinics.

Evaluation of the Malaria Rapid Diagnostic Kit in Ganghwa County (강화군에서 시행한 말라리아 신속진단킷트의 유용성 평가)

  • Kweon, Su-Jung;Kweon, Oh-Jun;Youn, Sung-Tae;Yim, Jun;Im, Jeong-Soo
    • Journal of agricultural medicine and community health
    • /
    • v.31 no.2
    • /
    • pp.157-164
    • /
    • 2006
  • Objectives: Early diagnosis and treatment is the most important strategy to control malaria effectively. Microscopic examination of blood films is a traditional and standard method for diagnosing malaria, which takes a long time and needs expertise, Therefore, the alternative method, rapid diagnostic kit has been used for quick diagnosis in some counties, a highly infectious region by P. vivax. The purpose of this study was to evaluate the utility of malaria rapid diagnostic kit in Ganghwa county. Methods: The utility was evaluated by mean diagnosis time and sensitivity and specificity. For monitoring mean diagnosis time, 942 cases which were diagnosed for P. vivax were collected between 1998 and 2005, And for calculating sensitivity and specificity, 434 whole bloods in EDTA which were presented for P. vivax by microscopy and rapid diagnostic kit were collected between 2004 and 2005. Results: After malaria rapid diagnostic kit was used in 2003, mean diagnosis time has decreased to 3.36-3.14 day. The sensitivity and specificity of the rapid diagnostic kit was 98.2% and 98,5% and comparable to that of microscopic examination. Conclusions: The malaria rapid diagnostic kit is useful tool in a highly infectious region like Ganghwa county.

  • PDF

How accurate are rapid diagnostic tests for covid-19? (코로나19 신속진단검사는 얼마나 정확한가?)

  • Yeo, In-Kwon
    • The Korean Journal of Applied Statistics
    • /
    • v.35 no.3
    • /
    • pp.435-443
    • /
    • 2022
  • In this paper, using Covid-19 diagnostic data provided by the Korea Disease Control and Prevention Agency (KDCA), we examine the probability of confirmed cases and the probability of actually being confirmed when the rapid test is negative according to the sensitivity and specificity of the rapid diagnostic kit. When we know the conditional probability of confirmation given a positive test, we induce the relationship between sensitivity and specificity, and compute the actual sensitivity of the rapid diagnosis kit based on the data of KDCA.

Nested-PCR and a New ELISA-Based NovaLisa Test Kit for Malaria Diagnosis in an Endemic Area of Thailand

  • Thongdee, Pimwan;Chaijaroenkul, Wanna;Kuesap, Jiraporn;Na-Bangchang, Kesara
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.4
    • /
    • pp.377-381
    • /
    • 2014
  • Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.

Diagnostic and Clinical Significance of KIT(CD117) Expression in Thymic Epithelial Tumors in China

  • Song, Nan;Chen, Gang;Zhang, Peng;Liu, Ming;He, Wen-Xin;Jiang, Ge-Ning
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2745-2748
    • /
    • 2012
  • Aims: To study KIT (CD117) expression in thymic epithelial tumors in China, and investigate diagnostic and clinical significance. Material and Methods: Thymic epithelial tumors (TETs) from 102 patients (3 type A, 29 type AB, 5 type B1, 22 type B2, 29 typeB3 and 16 thymic carcinomas) were examined. Immunohistochemical staining with an antic-kit monoclonal antibody was performed on a tissue microarray. Relationships between KIT positive expression and the TET clinical characteristics (WHO histologic classification and Masaoka stage system) were analysed. Results: The KIT positive expression rate was significantly higher in thymic carcinoma (60%, 9/16) than in thymoma (8%, 7/86), a strong correlation being found with the WHO classification, but not the Masaoka tumor stage. The overall survival for patients with KIT positive lesions was significantly worse. Conclusions: KIT is a good molecule marker to differentially diagnose thymic carcinoma from thymoma, while also serving as a predictor of prognosis for TETs. Further research into KIT mutations in Chinese TETs should be conducted to assess the efficacy of targeted therapy.

Effects of Optimal Heat Detection Kit on Fertility after Artificial Insemination (AI) in Hanwoo (Korean Native cattle) (한우 인공수정에서 수정적기 진단키트 활용이 수태율에 미치는 영향)

  • Choi, Sun-Ho;Jin, Hyun-Ju
    • Journal of Embryo Transfer
    • /
    • v.32 no.3
    • /
    • pp.153-157
    • /
    • 2017
  • This study was conducted to investigate the optimal artificial insemination (AI) time with diagnostic kit at ovulation time. We already applied the patent about the protein in the cow heat mucose in external reproductive tract. And we would examine the accuracy for detection of cow heat by the kit produced with the protein. Evaluation of optimal heat detection was tried two time at 12 hrs and 24 hrs after the heat. And then, AI service also performed two times with no relation to the results of heat diagnosis by heat detection kit and pregnancy rates were checked with rectal palpation on $60^{th}$ day after AI. Heat diagnostic results by kit in natural heat after 12 hrs in Hanwoo cows were showed 31.3~75.0% on positive in first heat detection and 33.3~100.0% on positve in second heat detection. In the $1^{st}$ positive results were significant different (p<0.05), but $2^{nd}$ positive were not. The results of heat detection showed different result on regional influence and individual cow effects. The pregnancy rates of first trial of heat detection were showed 34.4~78.7% on positive and 21.3~68.8% on negative after the diagnosis by heat detection kit. And the pregnancy rates of next trial of heat detection were showed 33.3~85.7% on positive and 14.3~66.6% on negative after the heat diagnosis. Both positive results of first trial and next trial also were showed significant different (p<0.05), but negative results were not. In positive result, first trial of total pregnancy rates was higher than the next trial of pregnancy, but there showed opposite results on negative results. In conclusion, the optimal heat detection kit is suitable to ordinary Hanwoo cows and it suggested that we have to improve the kit's accuracy by detecting the materials like proteins related optimal AI time.

Serodiagnosis of Extraintestinal Amebiasis: Retrospective Evaluation of the Diagnostic Performance of the Bordier® ELISA Kit

  • Beyls, Nicolas;Cognet, Odile;Stahl, Jean-Paul;Rogeaux, Olivier;Pelloux, Herve
    • Parasites, Hosts and Diseases
    • /
    • v.56 no.1
    • /
    • pp.71-74
    • /
    • 2018
  • Soluble antigens from an axenic culture of Entamoeba histolytica were used to develop a commercial ELISA kit to quantify anti-E. histolytica antibodies in sera of patients with extraintestinal amebiasis in non-endemic settings. The diagnostic specificity and sensitivity of the test were assessed retrospectively using 131 human serum samples with amoebic serologic status available. They were selected according to their results in immunofluorescence (IFAT) and were separated in 2 sample categories: 64 sera with positive results by IFAT and 67 with negative results by IFAT. The sensitivity and specificity of the ELISA kit were assessed at 95.0% and 94.0% compared to the IFAT. The test can be useful to exclude a potential diagnosis of amebiasis and could be used as a screening method since ELISA is an automated technique.

Facile and Effective Detection of Vitamin C on a Paper Based Kit (종이기반 소수성 채널에서의 효율적이고 간편한 비타민 C의 검출기술 개발)

  • Hwang, Jangsun;Seo, Youngmin;Choi, Jonghoon
    • KSBB Journal
    • /
    • v.31 no.1
    • /
    • pp.46-51
    • /
    • 2016
  • Recently paper based diagnostic kits have drawn great interest in the point-of-care testing market (POCT). The paper based detection systems provide inexpensive, rapid and safe analyses for disease markers and/or pathogens. Vitamin C (i.e., ascorbic acid) regulates body's immune system as an antioxidant agent. Humans, however, do not have enough amounts of enzymes involved in the synthesis of vitamin C that it is required to be obtained from their diets (e.g., beverages and/or supplements). Here, we have prepared a paper based kit to detect the concentration of Vitamin C presented in commercially available beverages. The evaluation provides the fast, simple and accurate results for detecting Vitamin C in the prepared paper based kit.