• Title/Summary/Keyword: Digital I%26C

Search Result 16, Processing Time 0.031 seconds

A Design of Effective Analog-to-Digital Converter Using RC Circuit for Configuration of I2C Slave Chip Address (I2C 슬래이브 칩의 주소 설정을 위한 RC회로를 이용한 효과적인 아날로그-디지털 변환기 설계)

  • Lee, Mu-Jin;Seong, Kwang-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.87-93
    • /
    • 2012
  • In this paper, we propose an analog-to-digital converter to set the address of a I2C slave chip. The proposed scheme converts a fixed voltage between 0 and VDD to the digital value which can be used as the address of the slave chip. The rising time and the falling time are measured with digital counter in a serially connected RC circuit, while the circuit is being charged and discharged with the voltage to be measured. The ratio of the two measured values is used to get the corresponding digital value. This scheme gives a strong point which is to be implementable all the parts except comparator using digital logic. Although the method utilizes RC circuit, it has no relation with the RC value if the quantization error is disregarded. Experimental result shows that the proposed scheme gives 32-level resolution thus it can be used to configure the address of the I2C slave chip.

Dicon Hot News

  • Korea Database Promotion Center
    • Digital Contents
    • /
    • no.10 s.161
    • /
    • pp.17-26
    • /
    • 2006
  • PDF

Clinical Studies for the Development of Non-contact Thermometer to Take Easily the Body Temperature of Domestic Animals (가축에서 간이 체온측정 비접촉성 체온계 개발을 위한 임상적 연구)

  • 김용준;이대영;한경호
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.357-363
    • /
    • 2003
  • These studies were carried out to develop non-contact thermometer to take easily the body temperature of domestic animals instead of taking rectal temperature. For the studies, 86 cattle, 57 horses, 72 pigs, 43 goats, and 42 dogs were used and body parts as neck, flank, axilla, lateral abdomen, gluteus, inguinal region, or jugular groove were chosen for taking temperature according to different species. Two types of commercial non-contact thermometers were used to take the temperature of certain body part and at the same time the rectal temperature using digital thermo-meter was taken to compare the difference of temperature between rectum and certain body part. The difference of mean temperature in cattle between rectum and axilla and flank were 0.52 and $2.41^{\circ}C$, respectively, using non-contact thermometer I, whereas $3.02^{\circ}C$ between rectum and flank using thermometer II. The difference of mean temperature in horses between rectum and axilla, gluteus, and jugular groove were 0.52, 1.49, and $0.26^{\circ}C$, respectively, using thermometer I, whereas 2.28 ane $0.92^{\circ}C$ between rectum and gluteus or jugular groove using thermometer II. The difference of mean temperature in swine between rectum and flank, inguinal region, and neck were 1.23, 0.21, and $0.8^{\circ}C$, respectively, using thermometer I, whereas 1.42, 0.711, and $1.25^{\circ}C$ using thermometer II The difference of mean temperature in goats between rectum and lateral abdomen and inguinal region were 1.02 and $0.12^{\circ}C$, respectively, using thermometer I, whereas 1.96 and $1.01^{\circ}C$ using thermometer II. The difference of mean temperature in dogs between rectum and lateral abdomen, inguinal region, and neck were 3.26, 0.24, and $2.37^{\circ}C$, respectively, using thermometer I, whereas 3.45, 0.56, and $2.61^{\circ}C$ using thermometer II.

DIGITAL TOPOLOGICAL PROPERTY OF THE DIGITAL 8-PSEUDOTORI

  • LEE, SIK;KIM, SAM-TAE;HAN, SANG-EON
    • Honam Mathematical Journal
    • /
    • v.26 no.4
    • /
    • pp.411-421
    • /
    • 2004
  • A digital $(k_0,\;k_1)$-homotopy is induced from digital $(k_0,\;k_1)$-continuity with the n kinds of $k_i$-adjacency relations in ${\mathbb{Z}}^n$, $i{\in}\{0,\;1\}$. The k-fundamental group, ${\pi}^k_1(X,\;x_0)$, is derived from the pointed digital k-homotopy, $k{\in}\{3^n-1(n{\geq}2),\;3^n-{\sum}^{r-2}_{k=0}C^n_k2^{n-k}-1(2{\leq}r{\leq}n-1(n{\geq}3)),\;2n(n{\geq}1)\}$. In this paper two kinds of digital 8-pseudotori stemmed from the minimal simple closed 4-curve and the minimal simple closed 8-curve with 8-contractibility or without 8-contractibility, e.g., $DT_8$ and $DT^{\prime}_8$, are introduced and their digital topological properties are studied by the calculation of the k-fundamental groups, $k{\in}\{8,\;32,\;64,\;80\}$.

  • PDF

A High-Efficiency Driver Design for Mobile Digital Audio Speakers (모바일용 디지털 오디오 스피커를 위한 고효율 드라이버 설계)

  • Kim, Yong-Serk;Rim, Min-Joon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.19-26
    • /
    • 2011
  • In this paper, we designed Interpolation FIR(Finite Impulse Response) filter and 1-bit SDM(Sigma- Delta Modulator) for small digital audio speaker, which has low power consumption and high output characteristics. In order to achieve high linearity and low distortion performance of the systems, we adopt Type I Chevychev FIR filter which has equiripple characteristics in the pass band and proposed high efficient FIR filter structure. SDM is the most efficient modulation technique among the noise shaping techniques. In this paper, we implemented SDM using CIFB(Cascade of Intergrators, Feed-Back) which is generally used in DAC of small digital audio speakers. The proposed SDM structure can achieve high SNR, high-efficiency characteristics and low power consumption in mobile devices. Also considering manufacture of SoC(System on Chip), we performed simulation with Matlab and Verilog HDL to obtain optimal number of operational bits and verified a good experimental results.

Improvement in computing times by the elimination of redundancies in existing DFT and FFT (DFT 및 FFT에 있어서의 Redundancies와 그의 제거에 의한 Fourier 변환고속화)

  • 안수길
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.14 no.6
    • /
    • pp.26-30
    • /
    • 1977
  • Redundancies in the Calculation of DFT and FFT are analized and new algorithms are proposed which are capable of reducing the machine time by a considerable amount. New extensions of T.D C.F. and T.D.F.T. are given for the discrete case which permit a deeper insights for the techniques of digital signal Proessing i. e. Discrete Fourier Transform, Convolution Sum and Correlation sequences.

  • PDF

A Comparision of the Radiation dose by Distance and the Direction according to a Tube Position of the C-arm Unit (C-arm의 Tube 위치에 따른 거리 및 방향별 피폭선량 비교)

  • Kim, Jin-Su;Woo, Bong-Cheol;Kim, Sung-Jin;Lee, Kwan-Sup;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • In operation room, the use of the C-arm unit is increasing. So, the radiation dose of the person who work in operation room was even more increased than before. Thus, this study is shown the measurement of expose dose and the way for decrease of the radiation dose by using the C-arm unit. The experiment was performed with the C-arm unit and used a phantom which is similar to tissue of the human body and fluoro-glass dosimeter for dose measurement. The expose dose were measured by the tube position(over tube, under tube) of the C-arm unit, distance(50, 100$\sim$200cm), direction(I, II, III, IV), runtime(1min, 3min), wearing of the apron. The radiation dose was decreased twice and three times at under tube rather than over tube. The I direction was measured 20$\sim$30% more than the others. The biggest expose dose is 50cm from center on distance. The expose dose is decreased to far from center. In case of Wearing of the apron, the radiation dose was decreased 60$\sim$90% by the distance. But there weren't change of the radiation dose by C-arm tube position. In present, by increasing the usage of the C-arm unit, the radiation dose is inevitable. So, this study recommends us to use the under tube of the C-arm unit. Also, Wearing of the apron is required for minimum of the radiation exposure.

  • PDF

Thermal Imager Implementation Using Infrared Sensor (적외선 센서를 이용한 열상장비의 구현)

  • Yu, W.K.;Yoon, E.S.;Kim, C.W.;Song, I.S.;Hong, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1250-1254
    • /
    • 1992
  • This paper describes the designed and fabricated thermal imaging system with the SPRITE(Signal PRocessing in The Element) detector, operating in the 3-12 micron band. This system consists of an afocal telescope, a scan unit containing the SPRITE detector, an electronic processor unit and a cooler. The optical scan system utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using five elements of the detector. And the electronic processor unit performs digital scan conversion to reform the parallel data stream into serial analog data compatable with conventional RS-170 video. The scan field of view is 40 ${\times}$ 26.7 and the MRTD(Minium Resolvable Temperature Difference) is 0.6 K at 7.5 cycles/mm. The acquired thermal image indicates that this system has a satisfactory performance.

  • PDF

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).

Body Composition Analysis Study of Postpartum Women With Cold-Hypersensitivity (수부냉증이 있는 산모의 체성분학적 특성 분석)

  • Lee, Mi-Joo;Lee, Chang-Hoon;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.9 no.1
    • /
    • pp.22-28
    • /
    • 2011
  • Purpose :To analyze body composition in postpartum women with cold-hypersensitivity, their edema index, skelectal muscle's weight and body fat were measured and analyzed with cold hypersensitive postpartum women compared with those of non-cold hypersensitivity. Methods : We studied 38 postpartum women visiting Gangnam Kyung-Hee Korean Hospital from 1 st October 2010 to 30th september 2011. they were subjected to Digital Infrared Thermal Imaging and those with thermal difference greater than $0.3^{\circ}C$ between anterior forearm and center of hand were diagnosed with cold hypersensitivity. Cold hypersensitivity group were consisted of 11 women, the other were consisted of 26 women. All of them were measured Edema index, skelectal muscle's weight and body fat by Inbody720(body composition scanner). We studied the difference of Body composition factor between two groups and relationship between cold-hypersensitivity, Edema index, skelectal muscle's weight and body fat by Independent Samples T-test and Spearman Correlation. Results : No significant differences were observed in edema index, skelectal muscle's weight and body fat between two groups. Conclusion : There was no significant relationship among the Cold-hypersensitivity and Body composition factor(Edema index, skelectal muscle's weight. body fat). But furthemore large scale study is required.

  • PDF