• 제목/요약/키워드: Digital Master Model

검색결과 63건 처리시간 0.026초

동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로 (Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system)

  • 김재홍
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.

CS-3500 구강 내 스캐너로 채득된 디지털 인상의 신뢰도 및 정확도 평가 (Reliability and Accuracy of Digital Impression Obtained from CS-3500 Intraoral Scanner)

  • 김사학;김재홍;김종견
    • 치위생과학회지
    • /
    • 제15권5호
    • /
    • pp.673-678
    • /
    • 2015
  • 본 연구는 최신 경향의 구강 내 스캐너로 채득된 3차원 디지털 인상의 정확도와 신뢰도를 평가하기 위해 4가지 계측 지점을 통하여 분석하였다. 주 모형과 비교하였을 때, 디지털 인상이 작게 계측되는 경향을 나타내었고, 각 계측지점별로 0.06~0.12 mm 범위의 차이를 보였다. 선행연구의 결과에 의해 임상적으로 오차범위를 허용할 수 있는 것으로 나타났으며, 환자의 진단이나 치아 교정치료 계획 수립 시 사용되는 모형에는 큰 영향이 없음을 확인할 수 있었다. 실험에서는 구강 내 상황이나 해부학적 구조를 무시하고 진행하였지만, 실제 임상에서 사용 시에는 구강 내 협소한 공간, 타액 등으로 인한 치아면의 난반사 증가, 혀 등의 해부학적 구조물로 인한 작업 방해 등의 여러 가지 요인이 인상과정에 영향을 줄 수 있을 것이라 판단된다. 추후 실험에서는 가능한 구강 내 상황을 재현한 상태에서 실험을 진행하면 좀 더 임상 적용에 도움이 될 것으로 생각된다.

스캐닝 방법에 따른 백색광 스캐너 기반으로 채득된 디지털 모형의 정확성 비교 (Comparison of the accuracy of digital models made from white light scanner by scanning method)

  • 김기백;이경탁;김재홍
    • 한국치위생학회지
    • /
    • 제12권6호
    • /
    • pp.1082-1089
    • /
    • 2012
  • Objectives : The aim of this study was to determine the accuracy of digitized stone models, impression materials compared to the master model and the reliability of the computer aided analysis. Methods : A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Ten vinyl polysiloxane impressions(Examix$^{(R)}$, GC Industrial Corp, Japan) of master model were taken and type IV stone(aesthetic-base gold$^{(R)}$, Dentona, Germany) were poured in stone models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK). The t-student test for paired samples was used for statistical analysis. Results : The mean differences to master model for stone model and impression material were 0.11~0.19mm, and 0.19~0.29mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between master model and stone model/impressions(p<.05). Conclusions : Two different scanning methods showed clinically acceptable accuracy of full arch digital impression produced by them. These results will have to be confirmed in further clinical studies.

Factors Influencing Customers to Use Digital Banking Application in Yogyakarta, Indonesia

  • MUFARIH, Muhammad;JAYADI, Riyanto;SUGANDI, Yovin
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권10호
    • /
    • pp.897-907
    • /
    • 2020
  • The development of information technology and the demands of society on an application in an operating system, as well as increasing the specifications and sophistication of smartphones, require banks to make changes to their mobile banking applications. The transformation of the mobile banking application into a digital banking application conducted by banks has made users re-evaluate based on their preferences. This study presents the behavior of users of digital banking applications in Yogyakarta, Indonesia. The hypothesis model is based on Technology Acceptance Model (TAM) with additional factors of the social image, perceived risk and perceived trust adopted from Muñoz-Leiva et al. (2017). The methodology in this study includes data collection through questionnaires distributed online and data analysis using the Structural Equation Model. The results of this study illustrate that the perceived trust and perceived risk have a more dominant part in influencing user attitude and user intention to use digital banking. Meanwhile, social image, perceived ease-of-use and perceived usefulness are not significant in influencing user attitude and user intention to use digital banking. The implication of this research helps to determine the right communication and strategy so that more users with more benefits can utilize this digital banking application.

A Study for Digital Transformation Based on Collaboration Master Plan for Shipbuilding & Marine Engineering Industry

  • Seung-Uk So;Myeong-Ki Han;Young-Hun Kim;Jun-Soo Park
    • 한국해양공학회지
    • /
    • 제37권5호
    • /
    • pp.190-197
    • /
    • 2023
  • In the shipbuilding and marine industry, digital transformation activities are promoted primarily by large shipyards. However, bottlenecks are observed across value chains, and digital transformation effects are reducing because of the cost and technical challenges encountered by supplies. In this study, we proposed a win-win cooperation model for large, small, and medium-sized companies using digital transformation based on the characteristics of the shipbuilding and marine industry through case studies. We investigated the digital transformation progress in German and Korean small and medium-sized enterprises (SMEs). In addition, we identified information-sharing methods and management challenges encountered in enterprise resource planning and manufacturing execution systems in the collaboration process of pipes, panels, blocks, etc. of SMEs that are suppliers of a Korean shipyard, and clarified communication by building a platform based on a common format between shipyards and suppliers. Further, we proposed a standard model of a digital transformation system for enhancing the collaboration between large companies and suppliers and proposed a basic plan including strategies to efficiently and effectively build a digital transformation system based on the standard model.

치과용 스캐너의 광원에 따른 디지털 모형의 정확도 비교연구 (Comparative study of accuracy of digitized model fabricated by difference optical source of non-contact 3D dental scanner)

  • 김재홍;이정수;심정석
    • 대한치과기공학회지
    • /
    • 제39권4호
    • /
    • pp.227-233
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by difference optical source of non-contact 3D dental scanner. Methods: A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the 3D dental scanner(Blue, white, red optical source). The linear distance between the reference points were measured and analyzed on the Delcam $Copycad^{(R)}$ graphic software. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test(${\alpha}=0.05$). Results: There were considerable differences in mean values between optical source within each color(blue, white, red), and this difference was not statistically significant(p>0.05). Conclusion : Three different color of dental scanner optical source showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

백색광 스캐너로 채득된 치과용 디지털모형의 정확도와 신뢰도 평가 (Evaluations of the Accuracy and Reliability of Measurements Made on White Light Scanner-based Dental Digital Models)

  • 김기백;김재홍
    • 한국콘텐츠학회논문지
    • /
    • 제12권10호
    • /
    • pp.357-364
    • /
    • 2012
  • 치과용 스캐너를 기반으로 하는 디지털 모형은 기존의 전통적인 석고모형을 대체할 만큼 발전되고 있다. 본 연구의 목적은 디지털모형의 정확도와 신뢰도를 평가하고자 하였다. 상악의 전악모형을 주 모형으로 설정하여 주 모형으로부터 석고모형을 제작하였고(N=10), 치과용 백색광 스캐너를 이용하여 10개의 디지털모형 데이터를 채득하였다. 제작된 두 실험군(석고모형, 디지털모형)을 1명의 검사자가 2회에 걸쳐서 6곳의 계측지점을 측정하였다. 짝 표본 t-검정과 급내 상관계수을 이용하여 통계적인 분석을 하였다. 실험결과 측정값의 검사자 내 신뢰도는 급내 상관계수 결과 두 실험군 0.75에서 0.87의 범위를 보였다. 석고모형과 디지털 모형의 평균 오차값은 0.11mm에서 0.23mm의 범위를 나타내었고, 모든 계측지점에서 통계적으로 유의한 차이를 보였다(P<0.05). 본 실험결과 모든 계측지점에서 적정수준의 정확성은 확보되지 않았으나, 선행연구에 비추어 볼 때 임상적인 효용성은 검증되었다. 추가적으로 임상적인 사례를 통해 평가되어야 할 것으로 사료된다.

CEREC$^{(R)}$ AC system으로 채득된 디지털 인상의 재현성, 정확성 평가에 관한 연구 (Reliability, accuracy of evaluations obtained from CEREC$^{(R)}$ AC system digital impression: an in-vitro study)

  • 김재홍;김기백;김혜영;김정애;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.121-128
    • /
    • 2012
  • Purpose: The aim of this study was to determine the reliability and accuracy of measurements in digital models(CEREC$^{(R)}$ AC) compared to stone models. Methods: A master model(500B-1, Nissin Dental Product, Japan) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CEREC$^{(R)}$ AC intra-oral scanner(n=10). One examiner measured two times the intercanine, intermolar distance, dental arch length. The stone model were measured using a digital caliper. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed very good reliability. At the intra-examiner reliability of measurement, ICC at the stone and CEREC$^{(R)}$ AC model were 0.81 and 0.94. The mean difference between measurements made directly on the stone models and those made on the CEREC$^{(R)}$ AC model was 0.20~0.28mm, and was statistically significant(P=0.001). Conclusion: These in vitro studies show that accuracy of the digital impression is similar to that of the conventional impression. These results will have to be confirmed in further clinical studies.

전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향 (The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression)

  • 김기백;이경탁;김혜영;김재홍
    • 치위생과학회지
    • /
    • 제12권6호
    • /
    • pp.617-623
    • /
    • 2012
  • 본 연구는 치과용 모형재 중 4형(type IV)석고와 스캔용(scannable)석고를 이용하여 작업모형을 제작한 후, 치과용 백색광 스캐너를 이용하여 3차원 디지털 모형으로 전환한 데이터의 계측지점간 거리를 측정하여, 그 결과 값을 토대로 이종의 치과용 석고가 3차원 디지털 모형의 크기재현 시 정확성여부를 비교하였다. 본 실험을 통하여 치과용 모형재에 따른 3차원 디지털 모형의 정확도를 확인함으로써 임상 적용의 가능성을 평가하였으며, 제한된 조건 하에서 수행된 본 연구에서 다음과 같은 결론을 얻었다. 1. 치과용 백색광 스캐너를 사용하여 주 모형과 두 종류의 모형재로 제작한 작업모형을 3차원 디지털 모형으로 전환한 후, 선계측의 값을 비교한 결과 전체적인 계측지점에서 모두 모형재로 제작된 작업모형이 작게 계측되는 경향을 보였다. 2. 각 모형별 동일한 계측지점의 계측값의 차이가 있는지 알아보기 위해 paired t-test의 시행결과, 모든 계측지점에서 통계적으로 유의한 차이를 보였다(p<0.05). 결론적으로 두 가지 석고 모두 통계적으로 적정한 수준의 정확성을 나타내지 않았으나, 오차 수준이 선행연구에 비추어 볼 때 임상적으로 수용 가능한 수준이라 생각된다. 전악 인상채득을 통한 디지털 모형의 정확성은 검증이 되었으나, 스캔용(scannable)석고에 대한 임상 효용성을 판단하기 위해 타 제품과의 성분 분석 비교연구나 실질적인 보철물 제작을 통한 적합도 평가를 통해 CAD/CAM 보철물 제작 시장점을 부각할 수 있는 연구가 뒷받침되어야 할 것으로 사료된다.

공공교육시설 설계프로세스의 디지털 건축 디자인 도입 가능성에 관한 연구 -계획설계 단계에서 BIM의 데이터베이스(DB)이용 중심으로- (A Study on the Possibility of Introduction of Digital Architectural Design by Public Education Facilities of the Design Process - Focus on Use the Database of BIM -)

  • 성기용;조병성
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권4호
    • /
    • pp.5-12
    • /
    • 2012
  • In this study, a digital design process by utilizing the program's database functionality in BIM, public education facilities master plan presented an alternative model to the layout of the design process. First of all, public education facilities master plan design process with digital design process and how to use the database of BIM in the process for review of the possibility of. Secondly, public educational facility planning the placement as needed for the switch to digital design limits, and the basic plan design at various elementary school planning alternatives in a school building and the school site is required to investigate. Thirdly, as a way of using the database features of GDL BIM lnn and teachers on how to create a variable by setting up a number of different alternatives so that you can choose the architect thought to have to organize and visualize the possibility of quick. A quantitative way the basic plan design that repeats some of the measures that can be used for digital design change as a process of continuous research is needed.