• 제목/요약/키워드: Direct Combination method

검색결과 172건 처리시간 0.025초

Optimum Directivity Synthesis of Ultrasonic Transducers Using Direct Inversion in Combination with Iterative DFP Method

  • K. R. Cho;Kim, C. D.;T. Tsuchiya;Y. Kagawa
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2001년도 The Seoul International Simulation Conference
    • /
    • pp.477-483
    • /
    • 2001
  • Optimum directivity synthesis of ultrasonic transducers in linear array is considered. To realize the desired directivity, a robust and efficient method is proposed which is the direct inversion combined with the iterative DFP (Davidon-Fletcher-Powell) method. A quasi-ideal beam with the beam width and the steering beam angle specified are chosen for the numerical demonstrations. The demonstration is then extended to the case of multi-beams. The proposed combination method shows quick convergence over the single LMS or DFP method at the expense of the system matrix inversion.

  • PDF

전력계통의 페이저 측정기 최적배치 (Optimal Placement of the Phasor Measurement Units in Power System)

  • 김재훈;조기선;김회철;신중린
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권7호
    • /
    • pp.313-322
    • /
    • 2000
  • This paper presents optimal placement of minimal set of Phasor Measurement Units (PMU's) and observability analysis of the network with PMU's. In order to find a observable system, a symbolic method which directly assigns an appropriate symbol for measurement or pseudo-measurement to every entry of node-branch incidence matrix is proposed. It is much simpler and easier to analyze the observability of the network with PMU's than the conventional ones. For the optimal PMU placement problem, two approaches which are based on a modified Simulated-Annealing (SA) method and a Direct Combination method are proposed. Some case studies with IEEE sample system are made to show the performance of the proposed methods are almost alike and more effective than the conventional simulated-annealing method. It is also shown that the Direct Combination method is more effective than the modified simulated-annealing one in the sense of computation burden. The results of this study showed also that the accuracy of power system estimation and system observability can be improved the proposed PMU placements.

  • PDF

Direct identification of aeroelastic force coefficients using forced vibration method

  • Herry, Irpanni;Hiroshi, Katsuchi;Hitoshi, Yamada
    • Wind and Structures
    • /
    • 제35권5호
    • /
    • pp.323-336
    • /
    • 2022
  • This study investigates the applicability of the direct identification of flutter derivatives in the time domain using Rational Function Approximation (RFA), where the extraction procedure requires either a combination of at least two wind speeds or one wind speed. In the frequency domain, flutter derivatives are identified at every wind speed. The ease of identifying flutter derivatives in the time domain creates a paradox because flutter derivative patterns sometimes change in higher-order polynomials. The first step involves a numerical study of RFA extractions for different deck shapes from existing bridges to verify the accurate wind speed combination for the extraction. The second step involves validating numerical simulation results through a wind tunnel experiment using the forced vibration method in one degree of freedom. The findings of the RFA extraction are compared to those obtained using the analytical solution. The numerical study and the wind tunnel experiment results are in good agreement. The results show that the evolution pattern of flutter derivatives determines the accuracy of the direct identification of RFA.

원판형 드래그펌프의 성능특성에 관한 연구 (A Study on the Performance Characteristics of a Disk-type Drag Pump)

  • 황영규;허중식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.643-648
    • /
    • 2001
  • The direct simulation Monte Carlo(DSMC) method is applied to investigate steady and unsteady flow fields of a single-stage disk-type drag pump. Two different kinds of pumps are considered: the first one is a rotor-rotor combination, and the second one is a rotor-stator combination. The pumping channels are cut on a rotor and stator. The rotor and stator have 10 Archimedes' spiral blades, respectively. In the present DSMC method, the variable hard sphere model is used as a molecular model, and the no time counter method is employed as a collision sampling technique. For simulation of diatomic gas flows, the Borgnakke-Larsen phenomenological model is adopted to redistribute the translational and internal energies. The DSMC results are in good agreement with the experimental data.

  • PDF

유한요소-전달강성계수법을 이용한 골조 구조물의 과도응답해석 (Transient Response Analysis of Frame Structures Using the Finite Element-transfer Stiffness Coefficient Method (FE-TSCM))

  • 최명수;문덕홍;김성진
    • 한국소음진동공학회논문집
    • /
    • 제12권9호
    • /
    • pp.674-684
    • /
    • 2002
  • In order to decrease remarkably the computation time and storage used in the direct integration method without the loss of accuracy, authors suggest a new transient analysis algorithm. This algorithm is derived from the combination of three techniques, that is, the transfer technique of the transfer stiffness coefficient method, the modeling technique of the finite element method, and the numerical integration technique of the Newmark method. In this paper, the transient analysis algorithm of a frame structure is formulated by the proposed method. The accuracy and computation efficiency of the proposed method are demonstrated through the comparing with the computation results by the direct integration method for three computation models under various excitations.

On the Vibration Analysis of the Floating Elastic Body Using the Boundary Integral Method in Combination with Finite Element Method

  • K.T.,Chung
    • 대한조선학회지
    • /
    • 제24권4호
    • /
    • pp.19-36
    • /
    • 1987
  • In this research the coupling problem between the elastic structure and the fluid, specially the hydroelastic harmonic vibration problem, is studied. In order to couple the domains, i.e., the structural domain and the fluid domain, the boundary integral method(direct boundary integral formulation) is used in the fluid domain in combination with the finite element method for the structure. The boundary integral method has been widely developed to apply it to the hydroelastic vibration problem. The hybrid boundary integral method using eigenfunctions on the radiation boundaries and the boundary integral method using the series form image-functions to replace the even bottom and free surface boundaries in case of high frequencies have been developed and tested. According to the boundary conditions and the frequency ranges the different boundary integral methods with the different idealizations of the fluid boundaries have been studied. Using the same interpolation functions for the pressure distribution and the displacement the two domains have been coupled and using Hamilton principle the solution of the hydroelastic have been obtained through the direct minimizing process. It has become evident that the finite-boundary element method combining with the eigenfunction or the image-function method give good results in comparison with the experimental ones and the other numerical results by the finite element method.

  • PDF

Multi-loop PID Control Method of Brushless DC Motors via Convex Combination Method

  • Kim, Chang-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.72-77
    • /
    • 2017
  • This paper proposes the explicit tuning rule of multi-loop PID controller for brushless direct current motors to predict the system behaviors in time and frequency domains, using properties of the convex combination method. The convex set of the proposed controllers formulates the envelope to satisfy the performances in time and frequency domains. The final control parameters are determined by solving the convex optimization problem subject to the constraints which are represented as convex set of time domain performances. The effectiveness of the proposed control method is shown in the numerical simulation, in which controller tuning algorithm and dynamics of brushless DC motor are well taken into account.

하수중의 Salmonella spp. 분리방법에 관한 비교연구 (A Study on the Salmonella spp. isolation method in the sewage specimens)

  • 김성수;염종화
    • 환경위생공학
    • /
    • 제10권3호
    • /
    • pp.35-44
    • /
    • 1995
  • This study was carried out in order to compare the methods for Salmonella spp. isolation from sewage and to settle the most appropriate conditions for that isolation. The direct enrichment method was more effective than the pre- enrichment method for Salmonella spp. isolation. The rate of detection was much higher when the specimens were enriched at $41.5^{\circ}C$ than when at $35^{\circ}C$. Usage of XLBG agar medium showed better results for Salmonella isolation than that of SS medium. It can be suggested that the most effective combination for Salmonella spp. isolation was the direct centrifugation(3,000 rpm 100m1)- direct enrichment($41.5^{\circ}$C)-usage of XLBG medium.

  • PDF

eXtended Statistical Combination of Uncertainties (XSCU) Method for Digital Nuclear Power Plants

  • In, Wang-Kee;Hwang, Dae-Hyun;Kim, Joon-Sung;Auh, Geun-Sun
    • Nuclear Engineering and Technology
    • /
    • 제30권6호
    • /
    • pp.617-627
    • /
    • 1998
  • A technically more direct Statistical Combination of Uncertainties (SCU) method, extended SCU (XSCU), was developed to statistically combine the uncertainties associated with the DNBR alarm setpoint and the DNBR trip setpoint of digital nuclear power plants. The Modified SCU (MSCU) method is currently used as the USNRC approved design method to perform the same function. In this study, the MSCU and XSCU methods were compared in terms of the total uncertainties, and the thermal margins to the DNBR alarm and trip setpoints. The MSCU method resulted in small total uncertainties due to large negative biases which are unphysical. The XSCU method gives virtually unbiased total uncertainties which are physically meaningful in order to represent the actual magnitude of the total uncertainties associated with the DNBR alarm and trip setpoints. But the thermal margins to the DNBR alarm and trip setpoints by the MSCU method agree with those by the XSCU method within allowable statistical Variations.

  • PDF

폭이 좁은 차량의 비상주행시 주행성능개선을 위한 제어시스템에 관한 연구 (A Study on the Control System of the Narrow Vehicles for Improvement of Maneuvering under Emergency Situation)

  • 소상균
    • 한국자동차공학회논문집
    • /
    • 제12권6호
    • /
    • pp.166-174
    • /
    • 2004
  • In urban area narrow commuter vehicles have attracted interest as a possible solution to reduce traffic congestion and parking problems. However, a narrow vehicle has an increased to overturn during hard cornering when compared to conventional vehicles. This tendency can be reduced by tilting it toward the inside of the turn. Two types of automatic tilting control systems which are Direct Tilt Control(DTC) and Steering Tilt Control(STC) have been developed. In this paper as one of the technique to improve the handling performance for the unusual vehicle the control system which blends both the DTC and the STC system is considered. It uses the merits of both the DTC and the STC system. As a control strategy for combination the switching control method is used. Finally, the fact that the unusual vehicle is safe under an emergency situation such as slippery road surface is proved by computer simulation.