• Title/Summary/Keyword: Directional overcurrent relay

Search Result 7, Processing Time 0.02 seconds

A Study on the Optimal Setting Method of Directional Overcurrent Relay Considering Fault Ride Through of Distributed Generation (분산전원의 Fault Ride Through를 고려한 방향성 과전류 계전기 최적 정정법에 관한 연구)

  • Song, Jin-Sol;Cho, Gyu-Jung;Kim, Ji-Soo;Shin, Jea-Yun;Kim, Dong-Hyun;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1002-1008
    • /
    • 2018
  • Fault Ride Through(FRT) requirement prevents disconnections of distributed generations during the specific time on disturbance condition for system stability. However, since there is a limitation to the FRT capability of distributed generation, and the protection system needs to clear the fault quickly before the distributed generation is disconnected. Therefore, this paper proposes a novel optimal setting method of directional overcurrent relay considering FRT of distributed generation. The proposed method reduces the probability of disconnections of the distributed generation in disturbance without additional equipment considering the FRT capability of the distributed generation by calculating the optimal relay setting through the Genetic Algorithm(GA).

An Innovative Fast Relay Coordination Method to Bypass the Time Consumption of Optimization Algorithms in Relay Protection Coordination

  • Kheshti, Mostafa;Kang, Xiaoning;Jiao, Zaibin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.612-620
    • /
    • 2017
  • Relay coordination in power system is a complex problem and so far, meta-heuristic algorithms and other methods as an alternative approach may not properly deal with large scale relay coordination due to their huge time consuming computation. In some cases the relay coordination could be unachievable. As the urgency for a proper approach is essential, in this paper an innovative and simple relay coordination method is introduced that is able to be applied on optimization algorithms for relay protection coordination. The objective function equation of operating time of relays are divided into two separate functions with less constraints. As the analytical results show here, this equivalent method has a remarkable speed with high accuracy to coordinate directional relays. Two distribution systems including directional overcurrent relays are studied in DigSILENT software and the collected data are examined in MATLAB. The relay settings of this method are compared with particle swarm optimization and genetic algorithm. The analytical results show the correctness of this mathematical and practical approach. This fast coordination method has a proper velocity of convergence with low iteration that can be used in large scale systems in practice and also to provide a feasible solution for protection coordination in smart grids as online or offline protection coordination.

Gray Wolf Optimizer for the Optimal Coordination of Directional Overcurrent Relay

  • Kim, Chang-Hwan;Khurshaid, Tahir;Wadood, Abdul;Farkoush, Saeid Gholami;Rhee, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1043-1051
    • /
    • 2018
  • The coordination of directional overcurrent relay (DOCR) is employed in this work, considering gray wolf optimizer (GWO), a recently designed optimizer that employs the hunting and leadership attitude of gray wolves for searching a global optimum. In power system protection coordination problem, the objective function to be optimized is the sum of operating time of all the main relays. The coordination of directional overcurrent relays is formulated as a linear programming problem. The proposed optimization technique aims to minimize the time dial settings (TDS) of the relays. The calculation of the Time Dial Setting (TDS) setting of the relays is the core of the coordination study. In this article two case studies of IEEE 6-bus system and IEEE 30-bus system are utilized to see the efficiency of this algorithm and the results had been compared with the other algorithms available in the reference and it was observed that the proposed scheme is quite competent for dealing with such problems. From analyzing the obtained results, it has been found that the GWO approach provides the most globally optimum solution at a faster convergence speed. GWO has achieved a lot of relaxation due to its easy implementation, modesty and robustness. MATLAB computer programming has been applied to see the effectiveness of this algorithm.

A New Scheme to Improve High Impedance Fault Detection Capability Using Directional Over-Current Ground Relay (방향지락과전류계전기를 이용한 고저항지락사고 검출능력의 향상방안)

  • Lee, Seung-Jae;Lim, Jong-Yun;Kim, Il-Dong;Han, Kyoung-Nam
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1000-1002
    • /
    • 1997
  • In this paper we proposes a scheme which can improve the detecting capability of the high impedance fault of the conventional distance relaying. It utilizes the directional ground overcurrent relay called HIFR together with the distance relay in order to secure the security and selectivity.

  • PDF

A Directional Relay Algorithm Using Positive-Sequence Superimposed Quantity for Transmission Line Protection (정상 성분 변화량을 이용한 송전선로 보호용 방향 계전 알고리즘)

  • 이명수;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.226-233
    • /
    • 2003
  • Directional elements are fundamental to protection scheme security and selectivity, performing such critical tasks as supervising distance elements and controlling overcurrent elements. But, conventional operating principles for directional detection based on negative or zero sequence quantify do not satisfy the requirements for improved sensitivity and fast operation under any fault conditions. In this paper, new algorithm for directional elements is proposed. The proposed algorithm use the positive-sequence superimposed voltages and currents in order to be used in all fault conditions. Also, because this algorithm uses a voltage compensation method. it can be well operated under strong source conditions.

A PSCAD Modeling of Protection Relay of On-Line Distribution System (PSCAD를 이용한 상시 루프배전시스템의 보호계전기 모델)

  • Kim, Jin-Su;Park, Jin-Hyeon;Cho, Bo-Hyeon;Moon, Won-Sik;Cho, Sung-Min;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.406-407
    • /
    • 2011
  • The closed-loop distribution system is more flexible and more reliable than radial system. If any type fault occurs, the reliability of system can be better by providing electrical energy through another distribution line. However, it needs protection device coordination of different type. Typically, it is available by using directional overcurrent relay (67). This paper gives a solution about loop protection relay modeling which can be used by the simulation tools.

  • PDF

An Overcurrent Analysis in Neutral Line and Algorithm to Prevent Malfunction of Relay in Distributed Generations (분산전원 연계선로에서 지락고장시 중성선의 과전류 해석 및 보호계전기의 새로운 알고리즘)

  • Shin, Dong-Yeol;Kim, Dong-Myung;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1916-1922
    • /
    • 2009
  • Introducing distributed generators(DGs) to utility distribution system can cause malfunction of relay on the grid when ground faults or severe load unbalances are occurred on the system. Because DGs interconnected to the grid can contribute fault currents and make bidirectional power flows on the system, fault currents from DGs can cause an interference of relay operation. A directional over current relay(DOCR) can determine the direction of power flow whether a fault occurs at the source side or load side through detecting the phases of voltage and current simultaneously. However, it is identified in this paper that the contributed fault current(Ifdg) from the ground source when was occurred to contribute single-line-to-ground(SLG) fault current, has various phases according to the distances from the ground source. It means that the directionality of Ifdg may not be determined by simply detecting the phases of voltage and current in some fault conditions. The magnitude of Ifdg can be estimated approximately as high as 3 times of a phase current and its maximum is up to 2,000 A depending on the capacity of generation facilities. In order to prevent malfunction of relay and damage of DG facilities from the contribution of ground fault currents, Ifdg should be limited within a proper range. Installation of neutral ground reactor (NGR) at a primary neutral of interconnection transformer was suggested in the paper. Capacity of the proposed NGR can be adjusted easily by controlling taps of the NGR. An algorithm for unidirectional relay was also proposed to prevent the malfunction of relay due to the fault current, Ifdg. By the algorithm, it is possible to determine the directionality of fault from measuring only the magnitude of fault current. It also implies that the directionality of fault can be detected by unidirectional relay without replacement of relay with the bidirectional relay.