• Title/Summary/Keyword: Disc changing

Search Result 51, Processing Time 0.027 seconds

Non-linearity characteristics consideration of the Disc Spring under Shock using Numerical Analysis (수치해석을 통한 충격 시 접시 스프링의 비선형 특성 고찰)

  • Bang, Seung-Woo;Lee, Hae-Jin;Kwon, O-Cheol;Lee, Jung-Youn;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1266-1271
    • /
    • 2007
  • General coil spring has linearity. However, disc spring has non-linearity so that using this non-linearity disc spring can be designed to do shock-absorbing in cases we need because shock response also has non-linearity. By changing the shape and stacking number, it is satisfactory with response of displacement, velocity and acceleration. Conventionally, disc spring was used to control the vibration against huge load and limited space. However, it is limitedly used because of difficulty of the designing guidance. Therefore, disc spring is needed to study further in order to apply it widely. Response of disc spring is compared to response of coil spring by changing ho/t radio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and effect of ho/t and stiffness is analyzed to broad usage so that design factor of disc spring is presented.

  • PDF

Non-linearity Characteristics Consideration of the Disc Spring Under Shock Using Numerical Analysis (수치해석을 통한 충격 시 접시 스프링의 비선형 특성 고찰)

  • Bang, Seung-Woo;Lee, Hae-Jin;Sim, Hyun-Jin;Park, Sang-Gil;Lee, Jung-Youn;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.2
    • /
    • pp.153-159
    • /
    • 2008
  • General coil spring has linearity. However, disc spring has non-linearity so that using this non-linearity disc spring can be designed to do shock-absorbing in cases we need because shock response also has non-linearity. By changing the shape and stacking number, it is satisfactory with response of displacement, velocity and acceleration. Conventionally, disc spring was used to control the vibration against huge load and limited space. However, it is limitedly used because of difficulty of the designing guidance. Therefore, disc spring is needed to study further in order to apply it widely. Response of disc spring is compared to response of coil spring by changing $h_o/t$ ratio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and effect of $h_o/t$ and stiffness is analyzed to broad usage so that design factor of disc spring is presented.

The effect of shape change of holes in rotating disc on disc strength (회전원판에 존재하는 구멍의 형상변화가 강도에 미치는 영향)

  • 김병진;심재준;한동섭;이성욱;한근조;안찬우;안성찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.796-799
    • /
    • 2002
  • The stress of the rotating disc with several types of hole was investigated in detail in this paper. Maximum circumferential stress of rotating disc by changing hole shape with same area, were studied using FEM. The results obtained were as follows: 1. The disc which rotates at high speed is subjected to circumferential stress remarkably. 2. When the number of circular holes in rotating disc is four, stress reduction effect is maximum. 3. When shape of holes in rotating disc is cylindrical elongated hole, maximum circumferential stress of the rotating disc decreased most.

  • PDF

Analysis of Disc Degeneration in a Poroelastic Spinal Motion Segment FE Model (다공탄성체 척추운동분절 유한요소 모델을 이용한 추간판의 퇴화과정 분석)

  • Woo D.G.;Kim Y.E.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.248-251
    • /
    • 2005
  • To investigate the degeneration process in the intervertebral disc, a three dimensional (3D) poroelastic finite-element (FE) model was developed. Disc was modeled as two different regions, such as annulus modeled with fiber reinforced 20 node poroelastic ground matrix and nucleus having large porosity. Excess Von Mises stress in the disc element assumed to be a possible source of degeneration under compressive loading condition. Recursive calculation was continued until the desired convergence was attained by changing the permeability and porosity of those elements, which could be predicted from the previous iteration. The degenerated disc model showed that relatively small compressive stresses were generated in the nucleus elements compared to normal disc. Its distribution along the sagittal plane was matched well with a previously reported experimental result. Contrasts to this result, pore pressures in the nucleus were higher than those in the normal disc. Total stress indicated similar values for two different models. This new approach using poroelastic modeling could provide the explanation of the interaction between fluid and solid matrix in the disc during the degeneration process.

  • PDF

Dynamic Instability of a Disc Brake Pad under Distributed Friction Force (분포마찰력을 받는 디스크 브레이크 패드의 동적 불안정)

  • Oh, Boo-Jin;Ryu, Bong-Jo;Yim, Kyung-Bin;Sugiyama, Yoshihiko;Ryu, Si-Ung
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.665-670
    • /
    • 2000
  • The paper presents the dynamic instability of a disc brake pad subjected to distributed friction forces. A brake pad can be modeled as a beam with two translational springs. The study of this prototypical model is intended to provide a fundamental understanding of disc brake pad instabilities. Governing equations of motion are derived form energy expressions and their corresponding solutions are obtained by employing the finite element method. The critical distributed friction force and the instability regions are demonstrated by changing two translational spring constants. Finally, the changes of eigen-frequencies of a beam determining instability types are investigated for various combinations of two spring constants.

  • PDF

ANALYSIS FOR 3-POINT LOADED DISC BY PHOTOELASTICITY (3점 압축하중을 받는 원판의 광탄성 해석)

  • 함경춘;이하성
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.1
    • /
    • pp.5-12
    • /
    • 1992
  • Disc specimen with the center crack and edge crack simulated by two-dimensional static method is used to analyze the stress field around the crack tip in terms of the stress intensity factor, K. A simple and convenient method of testing to realize the mifed mode stress intensity factor of the cracked body is used, The conclusions obtatined in this photoelastlc analysis are as follows ; 1. According to this experiment, cracked disc specimen can be used to demonstrate the mixed mode stress intensity factor analysis by simply changing the crack angle from the loading line. 2. Despite the simplicity and continuous data reading, the photoelastic method shows the slightly lower strain reading comparing to the FEM analysis method. 3. In this photoelastic analysis, $K_{I}$ of center cracked disc specimen under a pair of compressive load shows negative value as the crack angle increases over 30$^{\circ}$.

  • PDF

A Parametric Study on Double-Slit-Type Rupture Disc of Pulse Separation Device (펄스분리장치의 이중 슬릿형 파열판 매개변수 연구)

  • Han, Houk-Seop;Cho, Won-Man;Lee, Won-Bok;Koo, Song-Hoe;Lee, Bang-Eop
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.5
    • /
    • pp.101-110
    • /
    • 2010
  • Dual pulse rocket motor is a solid motor with two grains separated by a bulkhead and rupture disc. The elasto-plastic explicit dynamic analysis for the rupture disc was conducted by finite element method. The effect of the slit geometry of a rupture disc was parametrically analyzed in terms of rupture time and shape. The results can be used to control the rupture pressure by changing the slit geometry of rupture disc.

A Parametric Study on Rupture Disc with Radial Slit of Pulse Separation Device (원주방향 슬릿을 가진 파열판의 매개변수 연구)

  • Han, Houk-Seop;Cho, Won-Man;Lee, Won-Bok;Koo, Song-Hoe;Lee, Bang-Eop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.261-264
    • /
    • 2010
  • Dual Pulse Rocket Motor is a solid rocket motor with two grains separated by a bulkhead and rupture disc. The elasto-plastic explicit dynamic analysis of rupture disc was conducted by the finite element method. The effect of the slit geometry of rupture disc with radial slit was parametrically analyzed in terms of rupture time and shape. The results can be used to control the rupture pressure by changing the slit geometry of rupture disc.

  • PDF

A Clinical Analysis of Intervertebral Disc Change on Magnetic Resonance Imaging(MRI) Scan of the Patients Who were Diagnosed as Spondylolisthesis (척추전방전위증 환자에서의 자기공명영상 상 추간판 변형 형태 고찰)

  • Kim, Seok;Bahn, Hyo-Jung;Yoon, Hyun-Seok;Kim, Sun-Min;Jun, Byung-Chul
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.4
    • /
    • pp.119-130
    • /
    • 2011
  • Objectives: The purpose of this study is to find cut the characteristics of intervertebral disc changes arid relative factors of the patients with spondylolisthesis. Methods: We investigated 95 cases of patients who visited one Korean traditional medicine hospital and were diagnosed as spondylolisthesis on lumbar spine X-ray and lumbar spine magnetic resonance imaging(MRI). We selected these cases retrospectively and randomly. We analysed the relativity between number of changed discs and type of change disc and age, level of spondylolisthesis and type of spondylolisthesis. Results: 1. The number of changed discs increased with older and degenerative spondylolisthesis type(p<0.05) and was not related to the level of spondylolisthesis. 2. Bulging disc is the dominant type of disc change(74.12%). The type of changed disc was shown to be similar in lytic and degenerative spondylolisthesis. It was not relative to the level of spondylolisthesis(p>0.05). 3. The direction of nerve compression was diffuse type in about halfly of the patients(47.06%) and the symptoms of patent and dermatome did not matched in 54 cases. Conclusions: The patients who visited a Korean medicine hospital and were diagnosed as spondyolithesis have different characteristics from the established studies. Their discs changed dominantly to diffuse bulging type and the symptoms of patient were not related with the direction and level of the changed discs were spondylolisthesis existed.

Magnetic Resonance Imaging Analysis of Intervertebral Disc Change of Several Spondylolisthesis Patients in Fifties : Comparison Lytic and Degenerative Spondylolisthesis (일부 50대 척추전방전위증 환자의 유형별 자기공명영상상 추간판 변형 형태 고찰)

  • Kim, Seok;Bahn, Hyo-Jung;Yoon, Hyun-Seok;Han, Kyung-Wan;Woo, Jae-Hyuk
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.2
    • /
    • pp.13-22
    • /
    • 2011
  • Objectives : The purpose of this study is to find out the characteristics of intervertebral disc changes and relative factors of the spondylolisthesis patients in fifties by type of spondylolisthesis. Methods : We investigated 69 cases of patients who visited one Korean traditional medicine hospital and were diagnosed as spondylolisthesis on L-spine X-ray and L-spine magnetic resonance imaging(MRI). We selected 37 lytic spondylolisthesis patients and 32 degenerative spondylolisthesis patients. We analysed the relativity between the numbers of changed discs, types of changed disc, locations of nerve compression and types of spondylolisthesis. Results : 1. The number of changed discs increase in lytic type, but there is no statistically significant difference. 2. Bulging disc is the dominant type of disc change. There is no significant difference between two types. 3. Both foraminal type was shown dominantly in lytic spondylolisthesis, diffuse type in degenerative spondylolisthesis by the analysis of the location of the nerve compression. But the symptoms of patients and dermatome did not match in most of the cases. Conculsions : The direction of nerve compression is different while the disc changing aspects are similar in both types. In several spondylolisthesis patients in fifties, symptoms of patient are related to degeneration of vertebrae, not to the type of spondylolisthesis.

  • PDF