• 제목/요약/키워드: Discharge drain

검색결과 120건 처리시간 0.024초

지반특성을 고려한 연직배수재의 통수능 시험 및 선정 (The Discharge Capacity Test & Vertical Drain Adoption Considering the Ground Condition)

  • 정헌철;신경하;정기문;허집
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2007년 가을학술발표회
    • /
    • pp.373-382
    • /
    • 2007
  • In the vertical drain method, discharge capacity is generally one of the most important factor which affect on the estimation of the drain efficiency. However, adopting the drain considering discharge capacity only is not sufficiently considered method so that systematic criteria for adoption is necessary to choose the most suitable drain. Therefore, this study represents the application method considering behavior of the ground and vertical drain which is coupled together and ground improvement efficiency analyzing various cases of discharge capacity test performed in the recent soft ground improvement projects. According to the analysis, most drains tend to satisfy the required discharge capacity. It presents that deformed shape of the drains and well resistance estimation along the ground settlement, improvement efficiency by water content ratio along the depth and shear strength obtained after ground improvement should be considered altogether with the discharge capacity to select the proper drain. Also, appropriate adoption of drain material considering the ground condition is vital through analyzing the field measured data and comparing the result of the discharge capacity test as various vertical drain materials are being constructed continuously.

  • PDF

친환경배수재의 통수능 특성 평가 (Discharge Capacity of Environmentally Friendly Drains)

  • 조삼덕;김주형;정승용
    • 한국지반신소재학회논문집
    • /
    • 제4권1호
    • /
    • pp.27-36
    • /
    • 2005
  • 식물섬유에서 추출한 천연섬유를 이용하여 제작한 천연섬유배수재의 통수능을 평가하기 위해 수평배수재의 경우에는 투수시험 그리고 연직배수재의 경우에는 Delft 공대에서 개발한 통수능 시험과 교란 점토를 이용한 복합통수능 시험을 각각 수행하였다. 친환경 수평배수재에 대한 투수시험 결과 코코넛 껍질로 구성된 매트의 투수성은 모래에 비해 매우 우수한 것으로 나타났다. 또한, Delft 공대에서 개발한 통수능 시험으로 평가한 친환경 연직배수재의 통수능은 국산 플라스틱드레인보드의 통수능에 비해 매우 작은 것으로 나타났으나, 교란점토를 이용하여 실제 현장을 가깝게 모사한 복합통수능시험을 수행한 결과 친환경배수재와 플라스틱드레인보드를 설치한 지반의 침하나 간극수압 소산 양상이 서로 유사하게 나타나 친환경배수재가 배수재에 요구되는 최소통수능을 만족하는 것으로 나타났다.

  • PDF

토목섬유를 사용한 무처리 연약지반과 성토사이의 수평배수층 (Geotextiles Horizontal Drain between Earth Fills and Natural Soft Ground)

  • 이형규;공길용;김현태
    • 한국농공학회지
    • /
    • 제44권4호
    • /
    • pp.129-138
    • /
    • 2002
  • This paper presents a study on the discharge capacity of geotextiles as a horizontal drain layer placed between the layers of earth fill and natural soft ground. Required discharge capacity of geotextiles as drain layers estimated by consolidation analysis is proportional to the consolidation coefficient of the ground soils and the width of the earth fills. The field discharge capacity of the geotextiles are measured by the hydraulic transmissivity test. And the results show wide variation according to the material characteristics of geotextiles, water content of the soils, vertical pressure, and etc. For the short horizontal drain length, geotextile filter mat can be used for the horizontal drain layer. And f3r the long drain($25{\sim}55m$), it is used for the drain together with Bord Drain.

실내모형시험을 통한 연직배수재의 통수능력 및 스미어존 영향 평가 (A Assessment of Discharge Capacity of Vertical Drains and Smear Zone Effect from Model Test)

  • 천병식;김의석;도종남;국길근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1136-1143
    • /
    • 2008
  • The Vertical Drains(Sand Drains, Pack Drain, PBD) is used for Vertical Drains Method in domestic. Each of the drains is selected after it consider a field condition and efficiency of drain. A discharge capacity is very important factor, which to estimate a efficiency. And the smear Zone where disturbance area of in-suit by installation of Vertical Drains is important factor to select a drains. In this study, the complex discharge capacity test was operated for discharge capacity comparison of the Wing Drain and PBD. And a model test was operated to apprehend smear zone of the Wing Drain and PBD. From these tests, it was apprehended an engineering characteristic of vertical drain. The results of the complex discharge capacity test, a discharge capacity fell below $20cm^3/sec$ to $1cm^3/sec$ in more than overburden load $2.5kg/cm^2$. The Wing Drain maintained a over $40cm^3/sec$ in more than overburden load $2.5kg/cm^2$ and minimum discharge capacity $8cm^3/sec$. The results of the smear zone test, a influence bounds of smear zone was more larger in case of the Wing Drain(rectangle) than the PBD. But when a discharge capacity of Wing Drain is considered, it was concluded which smear zone bounds difference was effected in comparison with PBD. I think that it minimized a mandrel section to minimize a smear zone effect range

  • PDF

연직배수재가 타설된 지반의 복합통수능 해석 (Composite Discharge Capacity Analysis of Vertical Drain Installed in Ground)

  • 김창영;곽노경;이송
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1167-1174
    • /
    • 2008
  • Vertical drain method, which is one of the soft ground improvement methods, shorten s drain path to accelerate consolidation process and is applied in many sites. At a recent, composite discharge capacity experiment that analyze discharge amount by consolidation behavior with overburden pressure of soft ground in laboratory, simulates similarly with actuality. Geotechnical engineering problems such a s soft ground improvement are solved by numerical analysis by development of computer and numerical analysis techniques. Numerical analysis does that result is contrary by user's inexperience for choice of constitution model and application of analysis method. Therefore, this thesis experiments on composite discharge capacity test and study discharge capacity of drain and consolidation behavior of soft ground installed prefabricated vertical drain boards. Also, This thesis studied reasonable input parameters and constitution model by compare results of composite discharge capacity test and numerical analysis using PLAXIS that is 2D finial element numerical analysis program.

  • PDF

배수재의 직경과 형상변화가 수평진공배수에 미치는 영향 (Effects of Size and Shape of Drain on Horizontal Vacuum Drain)

  • 유남재;박병수;정길수;이병곤
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.293-301
    • /
    • 2001
  • This paper is experimental results of investigating the efficiency of horizontal vacuum drainage system. Effects of size and shape of drain on horizontal vacuum drainage were studied. Model tests in the laboratory with soft marine clay were carried out with drain pipe of having three different diameters and PBD (Plastic Board Drain) of strip shape so that consolidation settlement of soft clay due to applied vacuum pressure, amount of discharge, ground settlement and distributions of pore pressure and undrained shear strength were measured during testing. From results of model test, amount of discharge due to vacuum pressure was increased with the diameter of pipe drain whereas the drain efficiency of pipe in per unit area of drain surface was decreased with diameter of pipe. The rate of discharge per unit time was reduced very fast with diameter of pipe. Settlement of ground surface with time was increased with diameter of pipe as a result of increase of discharge to drain pipe.

  • PDF

연직배수재의 통수능력평가를 위한 실험적 연구 (An experimental study on the evaluation of discharge capacity for vertical plastic drain board)

  • Kim, Joonseok;Lee, Kangil
    • 한국재난정보학회 논문집
    • /
    • 제13권4호
    • /
    • pp.483-490
    • /
    • 2017
  • 최근 경제성장과 함께 산업용, 주거용 토지의 요구가 증대되고 있으나 좋은 지반조건으로 개발된 토지를 얻기가 어려워지고 있다. 샌드드레인, 모래다짐말뚝, 팩드레인, 프라스틱보드드레인(PBD)등 다양한 연직배수기술이 연약지반의 경제적 개발을 가능하게 하고 있다. 연직배수에서는 통수능력이 중요한 요소이다. 그러나, 현장조건에서는 토질조건, 상재하중 등 다양한 조건에 의하여 통수능력이 변화된다. 본 논문에서는 이중코어형 PBD, 대심도형 PBD, X형 PBD, 일반형 PBD등 4가지 다른 형태의 PBD에 대하여 통수능 시험이 수행되었다. 상재하중과 동수경사에 따른 통수능 특성을 분석하였다. 본 연구에서는 이중코어형의 통수능력이 가장 우수하였다.

DCVD 배수재의 성능평가 (A Perfomance Evaluation of the Deformation-Compatible Vertical Drain)

  • 송석규;천윤철;심재범;심성현;김영욱;이석원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.692-701
    • /
    • 2009
  • The use of vertical drain method to improve the soft soil ground has been continuously increased in Korea such as Busan New Port, Saemangeum reclamation project and so on in Korea. Especially PBD(Plastic Board Drain), one of the vertical drain, has been widely used due to the economic feasibility, construction compatibility and quality control. However in case of using PBD, discharge capacity reduction caused by creep deformation of the PBD filter, bending, kinking and so on can be occurred. Therefore the purpose of this study is to solve these problems by developing Deformation-Compatible Vertical Drain, DCVD which allows to deform with consolidation settlement without bending and kinking of vertical drain. In order to investigate the performance of DCVD developed in this study, discharge capacity test, centrifuge model test and complex discharge capacity test for both PBD and DCVD are performed and the results are compared.

  • PDF

십자형 연직배수재의 점성토지반 개량에의 적용성 (Applicability of Cross Shaped Drain to Soft Clay Improvement)

  • 장연수;김영우;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 토목섬유 특별세미나
    • /
    • pp.9-16
    • /
    • 2000
  • Applicability of the cross shaped drain in a soft clay ground is examined using the laboratory discharge capacity test, column consolidation test and 3-D numerical flow analysis. The equivalent diameter of the tested drains is back-calculated from the laboratory experiment and compared with those calculated from the formula suggested in the literature. The effective range of the cross shaped drain about the discharge capacity and coefficient of permeability is analyzed. The results of numerical analysis show that the cross shaped drain which has a cross-sectional area twice of the band shaped drain can reduce the consolidation time by 30% from that for the band shaped drain in a soft clay ground that K is over 1${\times}$10$\^$-7/cm/sec

  • PDF

천연마섬유배수재의 통수능력 향상에 관한 연구 (A Study on the Improvement of Discharge Capacity of Natural Fiber Drain)

  • 김지용;한상재;강민수;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.279-284
    • /
    • 1999
  • Fiber drain(FD), which is made of organic fibers from jute and coir, has recently been used in several construction projects in the Southeast and East Asia region involving the soil improvement of reclamation fills overlying marine clay. FD is an environmentally friendly product that will naturally be biodegraded into soil after the completion of performance duration as a vertical drain. However, the conventional FD has limited and low-ranged discharge capacity compared to PVD. For this, in this study, the improvement of FD was attempted and new shaped FDs were evaluated by laboratory tests. A series of discharge capacity test was performed to investigate the functional applicability for several types of FDs.

  • PDF