• Title/Summary/Keyword: Discharge power

Search Result 2,182, Processing Time 0.03 seconds

Characteristics of Ultra High Frequency Partial Discharge Signals from Metallic Particle Defected Oil-paper Insulation in Transformer (변압기 절연지 표면 금속 이물질 방전에 의한 극초단파 신호특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.879-883
    • /
    • 2009
  • This paper was provided to help in detecting defects in power transformer. For this purpose, a partial discharge cell was designed and manufactured as a discharge source to simulate particle defected paper-oil insulation in power transformer. Experimental set-up for measuring PD signals was described. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and pattern of PRPD(Phase Resolved Partial Discharge) of partial discharge signals were examined and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the substation faults.

A Study on Partial Discharge Diagnosis Using AI Algorism (인공지능 알고리즘을 이용한 부분방전 진단에 관한 연구)

  • Kim, Jin-Su;Kim, Il-Kwon;Park, Keon-Woo;Kim, Kwang-Soon;Kim, Young-Il
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1382-1383
    • /
    • 2008
  • In this paper, we have studied for analysis of the partial discharge(PD) signal based on fuzzy algorism. Partial discharge signal detector is difficult because of partial discharge signal is very non-linear. Also, it is very difficult work that separate partial discharge signal from noise. We constructed partial discharge accumulation detection system that use Labview for detection of non-linear partial discharge signal. And analyzed Partial discharge signal that is detected by Labview system utilizing Fuzzy model.

  • PDF

The measurement of partial discharge for preventive diagnosis in power machinery (전력용 기기의 예방진단을 위한 부분방전측정)

  • 김태성;구할본;임장섭;정우성
    • Electrical & Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.42-48
    • /
    • 1994
  • The preventive diagnosis technique for power system is being highlighted as a research area for deterioration of insulation in machinery because of high-voltage power system. We make efforts to develop not only diagnosis of aging state but also detection of defects in the initial stage from preventive diagnosis technique. Especially, partial discharge is actively studied as a non-destructive diagnosis technique and very useful because partial discharge measurement reduces damage than conventional diagnosis technique. The loaded stress during this test is smaller than that of other diagnosis techniques. But the continuous research for various complicated analysis method is required because partial discharge has very small signals and its signals have complex forms. In this paper, the measurement of partial discharge was investigated and studied on many specimens with void. We made samples having artificial voids and measured partial discharge. In order to use as a practical diagnosis technique, we studied ways of measurement, measured illustrations and types of partial discharge which could be used in order to diagnose defects of power machinery.

  • PDF

Properties on the Distribution Pattern of Discharge Signals Generated in the Power Cable (전력 케이블에서 발생되는 방전 신호의 분포패턴에 관한 특성 분석)

  • 소순열;홍경진;이우기;이동인;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.13-18
    • /
    • 1998
  • After Computer-based PD measurement was referred in the 1970's, the new technology and a number of digital system have been studied. And the selection of PD patterns, extraction of relevant information for PD recognition are discussed because the number of pulse as a function of discharge magnitude and discharge pulse as a function of the power frequency cycl4e offer the information of the aging insulation. This paper investigates the discharge phase($\phi$) and magnitude(q), as well as the number of discharge(n) with regard to discharge signals generated in power cable. Therefore, according to properties analysis on the distribution of $\phi$ , q and n, it is able to apply in the aging analysis of power cable which visual observation is impossible and distribution change of discharge signals offers much information for risk degree on aging progress of insulation materials.

  • PDF

Characteristics of Ultra High Frequency Partial Discharge Signals of Turn to Turn Defect in Transformer Oil (절연유 내 변압기 Turn간 결함에 의한 부분방전의 극초단파 전자기파 신호 특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2000-2004
    • /
    • 2009
  • In general, for the condition monitoring of a power transformer using the UHF PD measuring technique, detection of any partial discharge, identifying the defect in the transformer and locating the insulation defect are necessary. In this paper one of the most frequent detects which can result in turn to turn fault in power transformer was examined for identifying the defect. In order to model the defect, as a discharge source, a partial discharge cell was used for experimental activity. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and phase resolved partial discharge signals were measured and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the occurrence of transformer faults.

A Study on Energy Recovery Circuit in Sputtering Plasma Power supply for arc Discharge Prevention (스퍼터용 플라즈마 전원장치의 아크방지를 위한 에너지 회생회로에 대한 연구)

  • Ban, Jung-Hyun;Han, Hee-Min;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.3
    • /
    • pp.116-121
    • /
    • 2012
  • Recently, in the field of renewable energy such as solar cells including the semiconductor and display industries, thin film deposition process is being diversified. Furthermore, to deal with trend of making high-quality and fast, the high-capacity and output plasma power supply which can control high density plasma is required. The biggest problem is arc discharge caused by using high voltage power supply. Thus, the key function of plasma power supply is to prevent arc discharge and there is a need to maintain the possible minimum arc energy. In DC sputtering power supply, on a periodic basis (-)voltage powering up is able to significantly reduce arcing, as well as arc discharge prevention, and maintaining uniform charge density. This conventional method for powering up (-)voltage requires heavy mutual inductance of the transformer to avoid distortion problem of the output voltage. This study is about energy recovery circuit for arc discharge prevention in sputtering plasma power supply. By using energy recovery circuit, it is possible to reduce the mutual inductance and size of the transformer dramatically, prevent distortion of the output voltage and has a stable output waveform. This work was proved through simulation and experimental study.

A Study on Safety Treatment of NOx by Discharge Plasma Reaction (방전Plasma 반응에 의한 NOx의 안전처리에 관한 연구)

  • Choi, Jae-wook;Yamaguma, Mizuki
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.92-96
    • /
    • 2000
  • In this experiment, we studied about concentration characteristics of $NO_x$ and generation of ozone in the reactor of corona discharge type by using mixed gas of $NO/N_2$ and $N_2/O_2$. In the case of the initial NO concentration increased, decrease rate of NO concentration was weakened and discharge input power of minimum NO concentration became high. When NO concentration was high, NO decomposition limit was appeared. And NO reduction rate was decreased, when initial NO concentration and discharge input power increased. When discharge input power was 5W, we could know the most proper energy value for treatment of NO. When the concentration of initial NO increased, generation of ozone decreased and in the case of same concentration of NO, according to discharge input power increase, generation of ozone increased.

  • PDF

Numerical Investigation on the Water Discharge Capability of Tidal Power Plant Using CFD (CFD를 사용한 조력발전소 수문의 통수성능 연구)

  • Kim, Gunwoo;Oh, Sangho;Han, Insuk;Ahn, Sukjin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.161-161
    • /
    • 2011
  • The design methodology of the sluice caisson structure is one of important factor that is closely related to the efficiency in tidal power generation. When the sluice caisson is designed to maximize the water discharge capability, it is possible to minimize the number of sluice caissons for attaining the water amount required for achieving the target power generation, which results in reduction of the construction cost for the sluice caisson structure. The discharge capability of sluice caisson is dependent on the geometrical conditions of an apron structure which is placed in both sides of the sluice caisson. In this study, we investigated numerically the variation of water discharge capability of sluice caisson according to the geometrical conditions of apron. Flow fields are simulated with FLOW-3D software using VOF method.

  • PDF

A Study on Partial Discharge Diagnostic System for Power Cable using RLCR

  • Park, Keeyoung;Choi, Hyungkee;Lee, Chulhee;Hong, Soomi
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.1
    • /
    • pp.43-47
    • /
    • 2016
  • This system is a diagnosis system that checks whether it causes a partial discharge of a power cable or not. It is to classify normal from abnormal-normal, PD (Partial Discharge) sound through analysis of RLCR (Relative Level Crossing Rate) and spectrogram energy algorithm. Partial discharge diagnostic system has a function that stores PD sound and analyzes the data. The wave shape of PD sound is similar to noise and is systematically generated by partial discharge. Therefore, in this paper, we could discreminate between normal and abnormal case using relative level crossing rate (RLCR) and spectrogram of frequency energy rate.

Characteristics of Ozonizer with Variation of Vaccum in Internal Electrode (고주파전원형 오존발생기의 방전 캡 변화 특성)

  • 이창호;전병준;이상근;송현직;이광식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.381-385
    • /
    • 2003
  • In this paper, a co-axial type ozonizer varied with discharge gap was designed and manufactured for investigating $\circled1$ discharge characteristics with variation of output voltage power supply, flow rate and gap $\circled2$ ozone generation characteristics with variation of flow rate, gap and discharge power. pure oxygen was used as process gas of the co-axial type ozonizer. In this paper, a double cylindrical type superposed silent discharge type ozonizer which internal electrode can be produced a vacuum has been designed and manufactured. Discharge and ozone generation characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of internal electrode.

  • PDF