• Title/Summary/Keyword: Discharging voltage

Search Result 286, Processing Time 0.029 seconds

Design of a Bidirectional Converter for Battery Charging, Discharging and Zero-voltage Control (배터리 충, 방전 및 영전압 제어를 위한 양방향 컨버터 설계)

  • Choi, Jae-Hyuck;Kwon, Hyuk-Jin;Kwon, Jae-Hyun;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.431-437
    • /
    • 2022
  • This study proposes a converter that makes battery charging, discharging, and zero voltage control possible. The proposed topology consists of an LLC converter and a half-bridge inverter, and all power semiconductor devices are applied Si-MOSFETs. The topology is designed with an LLC switching frequency of 100 kHz, a half-bridge inverter switching frequency of 50 kHz, and a battery voltage of 5 V. The advantages of the charging/discharging operation of the 5 V battery voltage and the zero voltage control of the battery are verified. In addition, by using a two-stage topology, the battery can be charged, discharged through current control, and discharged to zero voltage. With the proposed topology, the current can be maintained even when the battery voltage drops to zero.

A Study on Stable Operation of Li-ion Battery Charging/Discharging System (Li-ion 배터리 충/방전 시스템의 안정적 운영에 관한 연구)

  • Yeo, Sung-Dae;Han, Cheol-Kyu;Cho, Tae-Il;Lee, Kyung-Ryang;Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.4
    • /
    • pp.395-402
    • /
    • 2016
  • When the operation of battery is converted at charging and discharging system based on a DC micro grid, the voltage is fluctuated. And excessive voltage fluctuation could cause damage or failure of charging and discharging equipment. Therefore, in this paper, we studied the operating schedule of the charging and discharging system based on the DC micro grid and a design point of the capacitor which was able to reduce the voltage fluctuation. A result of computer simulation showed that when a fluctuation-reducing capacitor which had an initial value of 600V/35mF was applied at the charging and discharging system based on a DC micro grid which was operated with three charging battery sets and five discharging battery sets, voltage fluctuation by charging and discharging operation was reduced by about 63.3%. Furthermore, voltage fluctuation which occurred when initial network voltage was stabilized was reduced by about 73%.

Functional Finishing of Nonwoven Filter for Dust-proof/Medical Masks by Corona Discharging Treatment (코로나 방전에 의한 방진/의료용 마스크 여과재의 기능화 가공)

  • Hong, Young-Ki
    • Textile Coloration and Finishing
    • /
    • v.25 no.3
    • /
    • pp.232-239
    • /
    • 2013
  • In this study, 25gsm melt-blown polypropylene nonwoven for dust-proof/medical masks was finished by the corona discharging treatment. The influence of corona discharging parameters on the filtration efficiency was investigated. Several parameters such as discharging voltage, discharging speed, distance to discharging wire and configuration of discharging system had an effect on filtration efficiency, while the parameters had no effect on breathing resistance. Optimum corona discharging conditions are as follows: Wires were installed on the upper part of the nonwoven and paper pipe was installed on the lower part of the nonwoven having a distance of 5cm. The sequence of wire voltages was +60 kV, +60 kV, 0, -60 kV, and -60 kV. The discharging voltage and speed were 60 kV and 30m/min respectively. The nonwoven treated by corona discharging at the optimum condition showed a filtration efficiency of 80% or more, which is suitable for dust-proof/medical masks.

Discharging Voltage Control with Error Detecting for Search light of Ship (선박용 탐사조명 전원장치의 방전개시전압 제어와 조명 이상검출)

  • Park, Noh-Sik;Kwon, Soon-Jae;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.8-17
    • /
    • 2008
  • This paper presents a stable lighting method for HID lamp for ship from initial discharging current limit with discharging voltage control. The output voltage of the proposed control scheme is boosted for ignition, and the charging voltage is decreased by the resistor discharging. The proposed controller fires the initial discharge at the designed discharging voltage to limit the discharge current. After the discharging, constant current controller is used for brightness in steady state. The proposed control scheme can limit the initial discharge current using the starting point control without a complex voltage controller. so it can improve the life-time of HID lamp and get a stable discharge from restricted the initial discharge current. In order to improve the protection of the system, a simple instantaneous error detecting circuit for open state and short state of HID lamp is used. The proposed error detecting of HID lamp can protect the power system of lamp control. The effectiveness of the proposed controller is verified from the experiments of practical 2.5[kW] HID search light for ship.

Battery State-of-Charge Estimation Algorithm Using Dynamic Terminal Voltage Measurement

  • Lee, Su-Hyeok;Lee, Seong-Won
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.2
    • /
    • pp.126-131
    • /
    • 2015
  • When a battery is discharging, the battery's current and terminal voltage must both be measured to estimate its state of charge (SOC). If the SOC can be estimated by using only the current or voltage, hardware costs will decrease. This paper proposes an SOC estimation algorithm that needs to measure only the terminal voltage while a battery is discharging. The battery's SOC can be deduced from its open circuit voltage (OCV) through the relationship between SOC and OCV. But when the battery is discharging, it is not possible to measure the OCV due to the voltage drop in the battery's internal resistance (IRdrop). The proposed algorithm calculates OCV by estimating IRdrop using a dynamic terminal voltage measurement. This paper confirms the results of applying the algorithm in a hardware environment via algorithm binarization. To evaluate the algorithm, a Simulink battery model based on actual values was used.

Development of High Voltage and High Energy Density Capacitor for Pulsed Power Application (펄스파워용 고전압 고에너지밀도 커패시터 개발)

  • 이병윤;정진교;이우영;박경엽;이수휘;김영광
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.203-210
    • /
    • 2003
  • This paper describes high voltage and high energy density capacitor developed for pulsed power applications. The rated voltage of the developed capacitor is DC 22 [kV], the capacitance is 206 [$\mu$F] and the energy density is about 0.7 [kJ/kg]. Polypropylene film and kraft paper were used as the dielectrics. The ratio of the thickness of each dielectric material which consists of the composite dielectric structure, stacking factor and the termination method were determined by the charging and discharging tests on model capacitors. In terms of energy density, the developed capacitor has higher energy density compared with the products of foreign leading companies. In addition, it has been proved that the life expectancy can be more over 2000 shots through the charging and discharging test. The voltage reversal factor was 20%. This capacitor can be used as numerous discharge applications such as military, medical, industrial fields.

The EMTP Analysis and Characteristics of Load Impedance on Various Electrode length, Pulse Repetition in Pulse Corona Discharging (펄스코로나 방전의 전극길이, 펄스반복율에 따른 부하 임피던스 변화 특성 및 EMTP 해석)

  • Jeong, Jong-Han;Song, U-Jeong;Jeon, Jin-An;Jeong, Hyeon-Ju;Hong, Jeong-Hwan;Kim, Hui-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.4
    • /
    • pp.158-163
    • /
    • 2002
  • The pulsed Power system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, often generator, etc. In this paper, we study EMTP analysis and characteristics of critical voltage and load in impedance on various electrode length of pulse corona. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a re sult, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

Low-cost crowbar system and protection scheme in capacitor bank module (커패시터 뱅크 모듈 구성에 있어서 경제적인 크로바 시스템과 보호회로)

  • Rim, Geun-Hie;Cho, Chu-Hyun;Lee, Hong-Sik;Pavlov, E.P.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2089-2091
    • /
    • 2000
  • Pulsed power systems consist of a capacitor bank, an isolated high-voltage charging power-supply, high-current bus-work for charging and discharging and a control system. In such pulsed power systems, the operating-lifetime of the capacitors is closely dependent on the voltage reversal. Hence, most capacitor-discharging systems includes crowbar circuits. The crowbar circuit prevents the capacitor recharging with reverse voltage. Usually it consists of crowbar resistors and high pulse-current diode-stacks connected in series. The requirements for the diode-stacks are fast-recovery time and high-voltage and large-current ratings, which results in the high cost of the pulsed-power system. This paper presents a protection scheme of a charging and discharging system of a 500kJ capacitor bank using a low-cost crowbar circuit and safety-fuses.

  • PDF

The charging and discharging specifications of the capacitor to the battery applied devices (배터리 적용 기기의 커패시터 충방전 특성)

  • Kim, Cherl-Jin;Hong, Sung-Ho;Lee, Soo-Rang;Kim, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1146-1148
    • /
    • 2007
  • This paper proposes a method to improve the charging speed and discharging performance of a high voltage capacitor used in a portable medical device. The improvement of the charging speed was achieved by duty cycle control. The discharging performance was carried out by varying the phase duration and the leading edge voltage of the output according to the transthoracic impdedance of the patient. As a result, the improvement in the charging speed and the performance of the discharging parameters shorten the patient treatment time.

  • PDF

Analysis of the battery charging and discharging system for spacecrafts (인공위성용 총방전 시스템의 해석)

  • 김영태;김희진
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.6
    • /
    • pp.932-942
    • /
    • 1995
  • A spacecraft power system can be divided into two types : DET system(Direct Energy Transfer system) and PPT system(Peak Power Tracking system). In a DET system employing the regulated bus voltage control method, the battery charger and discharger are widely used for the bus voltage regulation. The battery charger has two different modes of operation. One is the bus voltage regulation mode and the other is the charge current regulation mode. The battery discharger is employed to provide the power when the spacecraft is in the earth's shadow or the sun is eclipsed. The operating mode, charging or discharging, is selected by a power control circuit. In this paper, small-signal dynamic characteristics of battery charging and discharging system are analyzed to facilitate design of control loop for optimum performance. Control loop designs in various operating modes are discussed. Anaylses are verified through experiments.

  • PDF