• Title/Summary/Keyword: Dispenser

Search Result 132, Processing Time 0.024 seconds

Water quality analyses between tap water and treated water by point-of-use water dispenser systems (정수기 공급수인 수돗물과 정수기 통과수의 수질차이 분석)

  • Park, Keun-Young;Park, Ji-Won;Kim, Jae-Hyeok;Na, Yeong;Maeng, Sung-Kyu;Kim, Sung-Pyo;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.395-404
    • /
    • 2019
  • The point-of-use water dispenser systems are widely used because of convenience in handling and demand for high-quality drinking water. The application has been increased recently in the public places such as department stores, universities and the rest areas in express ways. Improvement of water qualities by the dispenser systems was compared with tap water in this study. The tap water is supplied to the dispenser as the influent of the dispenser system. The twelve dispensers in the public places were used. The five dispensers used reverse osmosis as the main filter and other dispensers used various filters such as ultrafiltration, nanofiltration, and alumina filter. The water quality indicators for sanitation safety, i.e., turbidity and total coliforms, were evaluated. Other water qualities such as pH, residual chlorine, heterotrophic plate count (HPC), and total cell counts were also analyzed. By the point-of-use water dispenser, the turbidity, residual chlorine and pH were decreased and the HPC and total cell counts were increased. The t-test results revealed that the HPC of the tap waters were not significantly different from the treated waters but the total cell counts of the two groups were significantly different. The low pH of the RO filter treatment was also significantly different from the tap waters. This study will contribute to understand the role of the point-of-use water dispenser in improving water quality and to identify key water quality for the proper maintenance of the dispenser systems.

Design of an One-Chip Controller for an Electronic Dispenser (전자 디스펜서용 단일 칩 제어기 설계)

  • Kim, Tae-Sang;Won, Young-Wook;Kim, Jeong-Beom
    • Journal of IKEEE
    • /
    • v.9 no.2 s.17
    • /
    • pp.101-107
    • /
    • 2005
  • This paper presents an one-chip controller for an electronic dispenser. The electronic dispenser is composed of electronic part and mechanical part. The electronic part is consisted of input keypad, micro-controller, display module, and pump module. In this paper we designed micro-controller for the electronic part. The micro-controller controls display module and pump module. The display module is composed by LCD device, and the pump module is composed by motor device . The micro-controller for an electronic dispenser is designed by VHDL. We used WX12864AP1 for the LCD device and SPS20 for the stepping motor. Also, the micro-controller is designed by Altera Quartus tool and verified with Agent 2000 Design-kit using APEX20K Device. In this paper, we present possibility to adopt of the biomedical device through the one-chip controller for the electronic dispenser.

  • PDF

A Study on the Preference of Old Women for the Higher Usability of u-Health Life Support Appliances (재가노인 유헬스 생활지원기기의 실용화를 위한 여성노인의 선호)

  • Kim, Sun-Joong;Park, Kyoung-Ok
    • Journal of the Korean housing association
    • /
    • v.20 no.1
    • /
    • pp.101-112
    • /
    • 2009
  • The purpose of this study is to find out the preference and the needs of old womens on the life support appliances i.e. medication dispenser, video phone, activity monitor and sleep monitor. The appliances may be improved reflecting the result of the questionnaire asking about the preferred functions and designs. The respondents were 141 female seniors of 65 years and older, living in Ulsan city or Cheongju city, Korea. Following is the list of results. (1) The medication dispenser, responded as highly preferred, met some worries over the troubles by power stoppage especially while one is out, letting her forget the medication time. (2) The video phone was worried over the cases of hearing failure by small sound, and watching failure by weakening sight. (3) The activity monitor, like the medication dispenser, was worried about the troubles while one is out or out of the monitoring scope, its expense, and the privacy, (4) The sleep monitor met the worries over the inadequacy for the sleeping mat on the floor and the emission of electromagnetic waves. (5) The preferred designs were (1) white or red standing medication dispenser, (2) wall-mounted video phone working by voice, (3) metal activity monitor sensor with white or yellow bracelet.

Experimental Analysis of Operating Parameters for Piezoelectric Jetting Dispenser (압전 젯팅 디스펜서의 작동 변수에 대한 실험적 분석)

  • Sohn, Jung Woo;Hong, Seung-Min;Kim, Gi-Woo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.10
    • /
    • pp.685-691
    • /
    • 2015
  • In this work, to identify effective parameter for performance of piezoelectric jetting dispenser, experimental investigation is carried out based on design of experiment. After preparing jetting dispenser using two stack-type piezoelectric actuators, basic working principle of the jetting dispenser is described. Eight operating conditions are chose as main factors and it is assumed that each factor has two levels. To reduce number of experiments for performance evaluation, the experimental sets are designed based on factional factorial design method. Experimental setup is established and the weight of single dot is measured by using precision scale. The main and interaction effects of factors are analyzed using commercial statistical program and optimal operating condition for small amount and small variation of weight of dispensed single dot are determined.

A Path Planning Algorithm for Dispenser Machines in Printed Circuit Board Assembly System (인쇄회로기판 조립용 디스펜서의 경로계획 알고리즘)

  • 송종석;박태형
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.6
    • /
    • pp.506-513
    • /
    • 2000
  • This paper proposes a path planning algorithm for dispensers to increase the productivity in printed circuit board assembly lines. We analyze the assembly sequence of the dispenser, and formulate it as an integer programming problem. The mathematical formulation can accomodate multiple heads and different types of heads through extended cost matrix. The TSP algorithms are then applied to the formulated problem to find the near-optimal solution. Simulation results are presented to verify the usefulness of the proposed scheme.

  • PDF

Performance Characteristics of High Frequency Jetting Dispenser Featuring Piezoactuator (압전작동기를 이용한 고주파수 젯팅 디스펜서의 성능 특성)

  • Yun, Bo-Young;Nguyen, Quoc Hung;Hong, Seung-Min;Sohn, Jung-Woo;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.595-600
    • /
    • 2007
  • This paper presents a new jetting dispenser driven by a piezoelectric actuator at high operating frequency to provide very small dispensing dot size of adhesive in modern semiconductor packaging processes. After describing the mechanism and operational principle of the dispenser, a mathematical model of the structured system is derived by considering behavior of each component such as piezostack and dispensing needle. In the fluid modeling, a lumped parameter method is applied to model the adhesive whose rheological property is expressed by Bingham model. The governing equations are then derived by integrating the structural model with the fluid model. Based on the proposed model, dispensing performances such as dispensing amount are investigated with respect to various input trajectories.

  • PDF

Performance Characteristics of High Speed Jetting Dispenser Using Piezoactuator (압전작동기를 이용한 고속 토출 젯팅 디스펜서의 성능 특성)

  • Yun, Bo-Young;Nguyen, Quoc-Hung;Sohn, Jung-Woo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.432-438
    • /
    • 2008
  • This paper presents a new jetting dispenser driven by a piezoelectric actuator at high operating frequency to provide very small dispensing dot size of adhesive in modern semiconductor packaging processes. After describing the mechanism and operational principle of the dispenser, a mathematical model of the structured system is derived by considering behavior of each component such as piezostack and dispensing needle. In the fluid modeling, a lumped parameter method is applied to model the adhesive whose rheological property is expressed by Bingham model. The governing equations are then derived by integrating the structural model with the fluid model. Based on the proposed model, dispensing performances such as dispensing amount are investigated with respect to various input trajectories.

Design of an One-Chip Controller for an Electronic Dispenser (전자 디스펜서용 단일칩 제어기 설계)

  • Won, Young-Uk;Kim, Jeong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.137-140
    • /
    • 2005
  • The electronic dispenser is composed of electronic part and mechanical part. Electronic part is consisted of input keypad, micro-controller, display module, and pump module. In this paper we designed micro-controller for electronic part. The micro-controller controls display module and pump module. The display module is composed by LCD device, and the pump module is composed by motor device. The micro-controller for an electronic dispenser is designed by VHDL. We used WX12864APl for the LCD device and SPS20 for the stepping motor. Also, the micro-controller is designed by Altera Quartus tool and verified with Agent 2000 Design-kit using APEX20K Device. In this paper, we present possibility to adopt of biotechnology field through designing of one-chip controller for an electronic dispenser.

  • PDF

A Study on the Preference of Feminine Seniors for the Higher Usability of Life Support Appliances (재가노인생활지원기기의 실용화를 위한 여성노인의 선호 연구)

  • Kim, Sun-Joong;Park, Kyoung-Ok
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.407-412
    • /
    • 2008
  • The purpose of this study is to find out the preference and the opinion of feminine seniors on the life support appliances(video phone, medication dispenser, activity monitor and sleep monitor). The appliances may be improved reflecting the result of the preferred functions and designs. The respondents were 141 feminine seniors of 65 years & older, living in Ulsan city or Cheongju city, Korea. Following is the result. 1) All the responses answered that the medication dispenser, video phone and activity monitor, sleep monitor are useful appliances. 2) All the seniors expressed prefer to function of the appliances, and were highly concerned about the price, safety and convenience. 3)The preferred designs were (1) white or red standing medication dispenser,(2) wall-mounted video phone working by voice, (3) metal activity monitor sensor like white or yellow bracelet.

  • PDF

A Study on the Heat Loss Improvement in a Refrigerator Ice Dispenser by Using Reverse Heat Loss Method (역열손실 방법을 이용한 냉장고 얼음 배출구 영역에서의 열손실 개선에 관한 연구)

  • Ha, Ji Soo
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2013
  • The present study has been carried out to reduce the heat loss from a built in refrigerator by using reverse heat loss method to discern the region with larger heat loss. To perform this purpose, an infrared thermographic camera has been used to measure the surface temperature of the refrigerator and tried to improve the heat loss near the ice dispenser. The numerical heat transfer analysis also has been accomplished to clarify the heat transfer mechanism near the ice dispenser. The possible applicable method to reduce heat loss was increasing the curvature radius at the ice dispenser corner. The curvature radius has been changed from 0mm to 40mm to see the effect of the curvature at the corner. From the present research, the optimal curvature radius for the reduction of heat loss at the ice dispenser could be 30mm.