• Title/Summary/Keyword: Doppler

Search Result 2,224, Processing Time 0.041 seconds

Comparison of Doppler and CT Angiography as a Predictor of Healing Diabetic Foot Ulcers (당뇨발 치유 가능성의 예측을 위한 도플러와 CT 혈관조영술의 비교)

  • Park, Doug-John;Kim, Hyon-Surk;Han, Seung-Kyu;Kim, Hee-Young;Chun, Kyung-Wook;Kim, Woo Kyung
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.495-500
    • /
    • 2008
  • Purpose: Adequate tissue oxygenation is considered as an essential factor for wound healing. In the non-diabetic population, an uncompromised macrocirculation generally leads to adequate tissue oxygenation. On the contrary, the macrocirculation in diabetic patients may not correlate with tissue oxygenation because of structural changes in the capillary basement membrane. Nevertheless, many medical professionals in Korea rely on macrocirculation evaluation when predicting wound healing potential of the diabetic ulcers. The purpose of this study is to compare reliability of two common macrocirculation assessment methods, Doppler probing and CT angiography, on tissue oxygenation in diabetic foot patients. Methods: Doppler and CT angiography scores were given according to the patency of the anterior and posterior tibial arteries. Tissue oxygenation was measured by transcutaneous partial oxygen tension($TcpO_2$). Doppler and CT angiography scores were statistically analyzed against $TcpO_2$ values. Sixty-eight diabetic foot ulcer patients were included in this study. Results: The test was carried out on Doppler score and $TcpO_2$ variables displayed a p-value of 0.0202, and concluded that the two variables were statistically dependent. The test used to determine for linear trends between Doppler scores and $TcpO_2$ variables displayed a p-value of 0.0149, displaying statistical linear trend between the two variables. On the contrary, the tests between CT angiography scores and $TcpO_2$ variables showed p-values of 0.1242 and 0.6590, that means no correlation between CT angiography and $TcpO_2$ scores. Conclusion: Doppler probing is more reliable than CT angiography in predicting tissue oxygenation of diabetic foot ulcers.

Range Walk Compensated Squint Cross-Range Doppler Processing in Bistatic Radar (바이스태틱 레이더에서 Range Walk이 보상된 Squint Cross-Range 도플러 프로세싱)

  • Youn, Jae-Hyuk;Kim, Kwan-Soo;Yang, Hoon-Gee;Chung, Yong-Seek;Lee, Won-Woo;Bae, Kyung-Bin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.11
    • /
    • pp.1141-1144
    • /
    • 2011
  • Range walk has been a major problem in achieving correct Doppler processing. This frequently occurs when range variation is severe just like in a bistatic radar or in high speed target scenario. This paper presents a range walk compensated range-Doppler processing algorithm applicable to the bistatic radar. In order for the compensation, a range-domain interpolation is applied for range compressed signal so that Doppler processing is performed along the evenly time-spaced range bins that contain target returns. Under a bistatic radar scenario, the proposed algorithm including a range domain pulse compression is mathematically described. Finally, the validity of the algorithm is demonstrated by simulation results showing the superiority of a SCDP(Squint Cross-range Doppler Processing) over an uncompensated Doppler processing.

Doppler Profile Extraction to Air-Breathing Targets with PT-Waveform Received Signal and Target Tracking Information on a Ground Radar (지상레이다의 PT-파형 수신신호와 항공기 추적정보를 이용한 항공기 도플러 프로파일 추출)

  • Oh, Hyun-Seok;Kim, Soo-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.2
    • /
    • pp.129-138
    • /
    • 2017
  • This paper has been shown for the extraction of Doppler signature from the radar signal for an air-breathing targets tracked in the ground radar. For the extractions, a Doppler resolution is confirmed from mathematical modeling of PT(pulse train) waveform. Doppler signatures of air-breathing target are varied to radar aspect angle of engine and are determined from physical parameter of jet engine. To confirm such Doppler signatures, the radar signal reflected from the air-breathing target is obtained by our radar signal storage. After this extraction, radar aspect angle of engine has estimated from tracking information. Relative differences of Doppler signatures to radar aspect angle of engine is verified from these results and Doppler profiles for radar target identification appliance are presented.

A Study on Spectrum Moment Estimation in an Acoustic Doppler Current Profiler (ADCP에서의 스펙트럼 모멘트 추정에 관한 연구)

  • Lee, Jonggil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.8
    • /
    • pp.1790-1795
    • /
    • 2013
  • The current velocity and turbulence information in each range cell can be obtained from the first and second Doppler spectrum moment estimates. However, the very widely used correlation method often called as the pulse-pair method has the inherent restrictions under the highly turbulent conditions since it does not satisfy the assumptions that the return Doppler spectrum should be symmetric and have a single peak value. Therefore, in this paper, the quality of pulse-pair estimates were compared with that of FFT estimates for problem analysis using various shapes of simulated Doppler spectra. It can be known that the pulse-pair method often yields meaningless results if the received signals are severely biased or multi-peak Doppler spectra in the Doppler frequency domain.

Improvement of the Directivity of a Doppler Log Using Linear Transducer Array (직선배열 진동자에 의한 도풀러 로그의 지향특성 개선에 관한 연구)

  • 신형일;정세모
    • Journal of the Korean Institute of Navigation
    • /
    • v.5 no.2
    • /
    • pp.1-39
    • /
    • 1981
  • A doppler log is the typical device which can measure the ship's speed over the ground directly, by means of doppler effect of the underwater ultrasonic wave, which involves the error due to the sea bottom inclination, the trim and the incorrect transducer installation etc. The present doppler log adopts a single transducer, faced in the direction of themain beam, and therefore it is unable to correct the beam direction to eliminate the above mentioned error. Moreover, the frequencyis also limitted in a comparatively high range for getting a sharp beam with single transducer, and the speed over the ground can not be detectable at the deep sea, for an instance, over 200 meters. This paper describes a theoretical consideration for the doppler log error and an analysis by a computer on the observed speed data by a full size model ship. The result is verified that the most of doppler log error is caused by the ultrasonic beam angle of transducer. To eliminate the doppler log error due to the incorrect transducer installation and also to sharpen the beam for lower frequency range to expand measurable sea depth, this paper proposes a method of controlling the directivity adopting a linear transducer array and of controlling the directivity by the control of exciting current, and investigates by the computer simulation and make experiment with magnetostrictive ferrite transducer of 28, 50 and 75KHz. The experimental results are shown well coincide with the measured ones, and they are revealed that in case where the transducer interval is greater than 1 wavelength, the effective control of the beam direction is hardly performed with keeping adequate beam width and side lobe level. It is concluded that 6-elements array with inter element space of a half wavelength can make comparatively sharp beam and low side lobe level. The results obtained here will contribute very much to the improvement of the performance of doppler log.

  • PDF

A Spatial Average Method Using 2nd Order Sampling in Ultrasonic Doppler System (초음파 도플러 시스템에서 2차 샘플링을 이용한 공간축상의 평균 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.279-288
    • /
    • 1995
  • Ultrasonic Doppler systems for the purpose of estimating blood flow velocity, blood flow volume, and flow imaging are commonly used due to advantages of non-invasive and real time observation. Specially, the technical developments of color flow mapping (2-D Doppler) systems have made a relatively rapid progress. However, the 2-D Doppler systems have several problems, such as the range ambiguity, low signal to noise ratio, and slow frame rate. The slow frame rate problem is resolved by using the spatial average which is a method to acquire more data samples for mean frequency estimation. In this paper, spatial average method using the 2nd order sampling instead of quadrature sampling is proposed. The experimental results show that the proposed methods have good performance and easy application to the color flow mapping system.

  • PDF

Transcranial Doppler Study in Stroke (뇌졸중에서의 경두개 초음파 검사)

  • Lee, Te Gyu
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.1
    • /
    • pp.60-63
    • /
    • 1999
  • Transcranial Doppler(TCD) is an important diagnostic tool for evaluating the patients with stroke. It has some advantages and unique role when compared with other neuroimaging modalities. Recent development of transcranial color-coded Doppler(TCD) improves the limitation and pitfalls of TCD. The current indications of TCD are as follows: 1. Screening and evaluation of the intracranial major vessels 2. early detection and follow-up of vasospasm due to SAH 3. emboli detection (high-imtensity transient signals, HITs) 4. dignosis and follow-up of subclavian steal 5. evaluation of intracranial collaterals when the extracranial ICA has severe stenosis or occlusion 6. evaluation of cerebral perfusion pressure (intracranial pressure) 7. evaluation of arteriovenous malformation 8. diagnosis and follow-up of arterial dissenction 9. diagnosis and follow-up of venous sinus thrombosis (experimental).

  • PDF

Fluidic velocity sensing with a speaker based optical doppler tomography (유속 센싱을 위한 스피커형 광학적 유체 단층촬영 기술)

  • Lee, Chang-Ho;Kim, Jee-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.317-324
    • /
    • 2008
  • This paper presents an optical doppler tomography(ODT) system using a speaker as a method to achieve depth measurement in a flowing sample. The use of the speaker provides easy implementation with a low cost. The nonlinear characteristics of the speaker has hindered its adaptation because it produces inconsistent fringe frequencies at different depths. This paper reports an adaptive algorithm to compensate the nonlinear characteristics, and could, resultantly, acquire the Doppler frequency shift caused by the sample. The experiment utilizes a flowing scattering particle solution in a capillary tube at a certain flow rate. The Doppler frequency profile over the lumen was calculated by using spectrogram method. and we obtained the velocity image of the sample.

A Study on Measurement of Heartrate and Respiration during Sleep using Doppler Radar: Preliminary Study (도플러 레이더를 이용한 수면 중의 심박 및 호흡 측정: 예비연구)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.264-270
    • /
    • 2017
  • A Doppler radar sensor was applied to detect respirations and heartbeats of persons who were lying on a bed. This study is preliminary study aiming at non-contact and non-intrusive respiration and heart rate monitoring during sleep in daily life. For the experiments, 10GHz Doppler radar with patch-type antenna was used and installed on the upper right and the distance between the body and the antenna was 1 m. The results show that each signal of respiration and heartbeat is observed in each frequency band however the frequency band and the waveform vary according to the subjects and the posture. The results show that the heartbeats can be detected with the peak detection in some frequency band. This study shows the feasibility of applying the Doppler radar to detection of heartbeat and respiration during sleep and further studies about heartbeat detection algorithm are required.