• Title/Summary/Keyword: Double-Cage

Search Result 31, Processing Time 0.029 seconds

The Development of Simulation Model for Calculating Hoisting Time of Double-Cage Construction Lift in Supertall Building Construction (Double-Cage 건설용 리프트의 양중시간 산정을 위한 시뮬레이션 모델 개발)

  • Kim, Wansoub;Lee, Dongmin;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.64-65
    • /
    • 2016
  • According to the recent increase in the height of supertall buildings, construction lift became one of most important equipment for vertical transportation of resources. However, increase in lifting load during peak time in which the resources are concentrated often causes a risk of construction delay. This study suggests a concept of Double-Cage construction lift, which is a lift with two cages attached together allowing transportation of resources on two consecutive work floors simultaneously. The aim of this study is to present a simulation model suitable for calculating hoisting time of Double-Cage construction lift. The proposed model is expected to be utilized when applying Double-cage construction lift for its efficient operation and management.

  • PDF

Characteristics Analysis for Motor or Generator Operating of Induction Machine with Deep or Double Cage Rotor (심구 또는 이중 농형 회전자를 가진 유도기의 전동 또는 발전 운전시 특성 해석)

  • Kim, Jong-Gyeum
    • New & Renewable Energy
    • /
    • v.10 no.4
    • /
    • pp.3-8
    • /
    • 2014
  • Both of induction generator and synchronous generator is available in the hydroelectric power plant. If the output of the power station is large, the synchronous generator is mainly used but when its output is low, the induction generator is often used. If the output capacity is small, there is a case in which induction motor is used as a generator. Torque at rated operation and start of the induction motor is different depending on the shape of the rotor. Small and medium-sized squirrel-cage induction motor is used primarily double cage rotor or deep bar. In this study, we attempt to interpret characteristics for double cage rotor or deep bar that occur when operating in the induction generator based on the parameters that have been designed and manufactured as an induction motor.

Simulation of three-phase symmetrical squirrel cage induction motors with double rotor bars (대칭3상2중롱형유도전동기의 시뮬레이션)

  • 임달호;이은웅;장석명;구태만
    • 전기의세계
    • /
    • v.30 no.6
    • /
    • pp.366-374
    • /
    • 1981
  • In most cases, simulation of induction machines under dynamic conditions have been based on two-phase models using constant circuit parameters. Squirrel cage induction machines with double rotor bars which are made for high starting torgue have lower rotor bars of sufficient depth they cannot be accurately represented by a constant rotor resistance under all operating condition. In this paper, the circuit of three-phase symmetrical induction machines is represented in two-axis model by tensor. A method for simulating three-phase squirrel cage induction machines in a dynamic conditions is presented, and the current distribution in double rotor bars is calculated under dynamic conditions.

  • PDF

A Study on the outside rotor type double squirrel cage Induction motor (외측회전형 이중 농형 유도전동기에 관한 연구)

  • 김현수;배철오;안병원
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.776-782
    • /
    • 2003
  • This paper describes a newly developed double squirrel cage induction motor in which the rotor is located outside the stator. The outside rotor type brushless dc motor has been used for VTR's head drum and PC's cooling fan, but this kind of induction motor has not been developed yet. The parameters of outside rotor type induction motor were measured from the locked rotor test and no load test. It is possible to determine the parameters which are presented in the steady-state equivalent-circuit of the outside rotor type induction motor. Load test of induction motor was carried out using a dynamometer. For the characteristics of torque, efficiency, power factor and output. the developed double squirrel cage induction motor is compared with the ordinary induction motor It is believed that the results of this paper can be used for the development of the outside rotor type induction motor.

The analysis on magnetic flux by the rotor slot of Squirrel-cage induction motor (농형유도전동기(籠型誘導電動機)의 회전자(回轉子) 슬롯 형상(形狀)에 따른 자속밀도(磁束密度) 해석(解析))

  • Oh, Young-Soo;Lee, Eun-Woong;Lee, Dong-Ju;Moon, Jae-Yun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.299-301
    • /
    • 1998
  • The torque characteristic of an induction motor is affected greatly by the slot shape at which the conductors of the rotor are located. In this paper, the three analysis model; general type, deep slot type, double squirrel-cage type, of which the slot shapes are different, were analyzed by FEM at no load, at rated load, and at standstill respectively. The flux distribution and air-gap flux density were also obtained. From the above result, it was confirmed that the analysis models of deep slot and double squirrel-cage had more desirable characteristics than those of general squirrel-cage.

  • PDF

Study on the Operating Characteristics of Double Fed Induction Generator Connected AC network (계통 연계형 권선형 유도발전기의 동작특성 연구)

  • Kim, Chan-Ki;Han, Sang-Yul;Choo, Jin-Boo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.247-257
    • /
    • 2006
  • This paper shows the comparison of operating characteristics between squirrel cage induction generator and DFIG(Double Fed Induction Generator). Because squirrel cage induction generator consume the reactive power due to magnetizing reactance, the capacitor is need to compensate the reactive power. Otherwise, two back-to-back PWM voltage-fed inverters connected between the stator and the rotor allow sub/super synchronous operation with low distortion currents. In this paper, the response characteristics of squirrel cage induction generator and DFIG, were analyzed and investigated using PSCAD/EMTDC.

Study on the Operating Characteristics of Double Fed Induction Generator Connected AC network (계통 연계형 권선형 유도발전기의 동작특성 연구)

  • Kim Chan-Ki;Park Jong-Kwang;Choi Young-Do;Lim Seong-Joo;Moon Hyoung-Bae
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.323-326
    • /
    • 2006
  • This paper shows the comparison of operating characteristics between squirrel cage induction generator and DFIG(Double Fed Induction Generator). Because squirrel cage induction generator consume the reactive power due to magnetizing reactance, the capacitor is need to compensate the reactive power. Otherwise, two back-to-back PWM voltage-fed inverters connected between the stator and the rotor allow sub/super synchronous operation with low distortion currents. In this paper, the response characteristics of squirrel cage induction generator and DFIG, were analyzed and investigated using PSCAD/EMTDC.

  • PDF

A Study on the Variable Speed Control Characteristics of Outside Rotor type Squirrel Cage Induction Motor (외측 회전형 농형 유도전동기의 가변속 운전특성에 관한 연구)

  • 안병원;박영산;노영오;최민선;김성환;김현수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.418-422
    • /
    • 2001
  • This paper presents a developed squired cage induction motor for axial flow fan. The developed squirrel cage induction noter for axial flow fan is exchanged the position, rotor and stater. In this method a fan blade is attached to outside rotor. So we can protect the motor from rain and reduce noise, and there is no need to have bending duct to locate the fan motor. Carried out experimental test with this induction motor, and the results were as follows. Starting torque was 21kgㆍcm@120V, maximum efficiency was 0.84@120V. The characteristics of tests were the same as double squirrel-cage type IM.

  • PDF

Anterior Cervical Discectomy and Fusion Using a Double Cylindrical Cage versus an Anterior Cervical Plating System with Iliac Crest Autografts for the Treatment of Cervical Degenerative Disc Disease

  • Kim, Seong Joon;Kim, Sang Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.1
    • /
    • pp.12-17
    • /
    • 2014
  • Objective : Anterior cervical discectomy and fusion (ACDF) is often complicated by subsidence, pseudoarthrosis, kyphosis, and graft donor site morbidities. To decrease the occurrence of these complications, various types of cages have been developed. We designed this retrospective study to analyze and compare the efficacy and outcomes of ACDF using double cylindrical cages (DCC) (BK Medical, Seoul, Korea) versus an anterior cervical plating system with autogenous iliac crest grafts. Methods : Forty-eight patients were treated with autograft and plating (plate group), and 48 with DCC group from October 2007 to October 2011. We analyzed construct length, cervical lordotic curvarture, the thickness of the prevertebral soft tissue, segmental instability, and clinical outcomes. Results : There were no significant differences between the two groups with regard to the decrease in construct length or cervical lodortic curvature at the 3-, 6-, and 12-month follow-ups. The prevertebral soft tissue was thinner in the DCC group than the plate group immediately after surgery and at the 3-, 6-, and 12-month follow-ups. The difference in interspinous distance on flexion-extension was shorter in the plate group than the DCC group at the 3- and 6-month follow-ups. However, there was no significant difference in this distance between the two groups at the 12-month follow-up. Conclusion : A double cylindrical cage is a good alternative for fusion in patients with cervical degenerative diseases; the surgical method is relatively simple, allows good synostosis, has less associated prevertebral soft tissue swelling, and complications associated with autografting can be avoided.

Uptake Effects of Two Electrons for Relative Stability and Atomic Structures of Carbon Cluster Isomers of C20: ab initio Methods

  • Lee, Wang-Ro;Lee, Chang-Hoon;Kang, Jin-Hee;Park, Sung-Soo;Hwang, Yong-Gyoo;Lee, Kee-Hag
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.2
    • /
    • pp.445-448
    • /
    • 2009
  • This study examined the effect of the uptake of one and two electrons on the atomic structure of three isomers of $C_{20}$ clusters, namely the ring, bowl (corannulene like), and cage (the smallest fullerene). Geometry optimizations were performed using the hybrid density functional (B3LYP) methods for neutral, singly and doubly charged $C_{20},\;{C_{20}}^-,and\;{C_{20}}^{2-}$. These results show that the symmetry of the lowest energies for ring and bowl isomers were not changed, whereas the increasing order of energy for the cage (the smallest fullerene) isomers was changed from $D_{2h}\;<\;C_{2h}\;{\leq}\;C_2\;of\;C_{20}\;through\;Ci\;<\;C_{2h}\;<\;C_2\;<\;D_{2h}\;of\;{C_{20}}^-\;to\;Ci\;<\;C_2\;<\;D_{2h}\;<\;C_{2h}\;of\;{C_{20}}^{2-}$. The reduced symmetry isomers of the cage have comparative energy and the ground state symmetry of the neutral and single and double charged $C_{20}$ decreased with increasing number of electrons taken up in the point of energetics. Interestingly, the difference in energy between the ground state and the next higher energy state of ${C_{20}}^{2-}$ was 3.5kcal/mol, which is the largest energy gap of the neutral, single anion and double anion of the cage isomers examined.