• Title/Summary/Keyword: Droop

Search Result 204, Processing Time 0.032 seconds

Fuzzy Droop Control considering SOC Balancing of BESSs (다수 BESS의 SOC Balancing을 고려한 퍼지 드룹 제어)

  • Han, Seong-Geun;Yoo, Hyeong-Jun;Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.616-622
    • /
    • 2015
  • A microgrid which is composed of distributed generation systems, energy storage systems and loads is operated in the grid-connected mode and in the islanded mode. Especially, in the islanded mode, a microgrid should maintain frequency in the allowed range. The frequency is decided by a balance between power supply and power demand. In general, the frequency is controlled by using battery energy storage systems (BESSs) in the microgrid. Especially, droop control is applied to controlling BESSs in the microgrid. Meanwhile, over-charging and deep-discharging of BESS in operation and control cause life-shortening of batteries. In this paper, a fuzzy droop control is proposed to change droop gains adaptively by considering state of charge (SOC) of BESSs to improve the life cycle of the battery. The proposed fuzzy droop control adjusts droop gains based on SOC of BESSs in real time. In other to show the performance of the proposed fuzzy droop control, simulation based on Matlab/Simulink is performed. In addition, comparison of the convention droop control and the proposed fuzzy droop control is also performed.

Estimating PMSG Wind Turbines by Inertia and Droop Control Schemes with Intelligent Fuzzy Controller in Indian Development

  • Josephine, R.L.;Suja, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1196-1201
    • /
    • 2014
  • This paper presents an exploration on the effect of wind turbine contribution to the frequency control of individual systems that can be used for efficient power production in India. The research includes the study of Permanent Magnet Synchronous Generator (PMSG), in wind farms. The WTs are tested for inertia and for droop responses with intelligent fuzzy logic controllers (FLC) that choose Double Input Single Output (DISO) strategy that automatically sets gain constants, as well as combined responses for the WTs. Quantitative analyses are presented for the WTs for benefits and drawbacks including appropriate selection parameters. The analysis includes inertia, droop and combined inertia, droop schemes. The reconnaissance also incorporates inertia with FLC, droop with FLC, inertia and droop with FLC schemes for detailed study of WTs, so as to forecast and achieve proper frequency control. Moreover, the analysis provides the best suited method for frequency control in PMSG.

Temperature Dependence of Efficiency Droop in GaN-based Blue Light-emitting Diodes from 20 to 80℃

  • Ryu, Guen-Hwan;Seo, Dong-Joo;Ryu, Han-Youl
    • Current Optics and Photonics
    • /
    • v.2 no.5
    • /
    • pp.468-473
    • /
    • 2018
  • We investigate the temperature dependence of efficiency droop in InGaN/GaN multiple-quantum-well (MQW) blue light-emitting diodes (LEDs) in the temperature range from 20 to $80^{\circ}C$. When the external quantum efficiency (EQE) and the wall-plug efficiency (WPE) of the LED sample were measured as injection current and temperature varied, the droop of EQE and WPE was found to be reduced with increasing temperature. As the temperature increased from 20 to $80^{\circ}C$, the droop ratio of EQE was decreased from 16% to 14%. This reduction in efficiency droop with temperature can be interpreted by a temperature-dependent carrier distribution in the MQWs. When the carrier distribution and radiative recombination rate in MQWs were simulated and compared for different temperatures, the carrier distribution was found to become increasingly homogeneous as the temperature increased, which is believed to partly contribute to the reduction in efficiency droop with increasing temperature.

Autonomous Operation Analysis of DC Microgrid based on Droop Control (Droop 제어를 기반으로 한 직류 마이크로그리드의 자율 동작 분석)

  • Lee, Ji-Heon;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.342-350
    • /
    • 2011
  • This paper describes the autonomous operation analysis of DC microgrid based on droop control. In order to verify the whole system operation, detailed simulation models for wind power generation, solar power generation, and battery were developed with user-defined models programmed with C-code in PSCAD/ EMTDC software. The simulation results confirm that the DC microgrid with droop control make it feasible to provide power to the load with stable manner. Based on simulation results a prototype of DC microgrid was built and tested in the lab to verify the autonomous operation experimentally. The droop control scheme can suppress the circulating current, and offers each unit to be controlled autonomously without any communication link.

Parallel Operation Method using New Cubic Equation Droop Control of Three-Phase AC/DC PWM Converter for DC Distribution Systems (DC배전용 3상 AC/DC PWM 컨버터의 새로운 3차방정식 Droop 제어를 적용한 병렬운전 기법)

  • Shin, Soo-Choel;Lee, Hee-Jun;Park, Yun-Wook;Hong, Seok-Jin;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.233-239
    • /
    • 2014
  • This paper proposes that each converter supplies the power using the proposed droop control for the parallel operation of the converters. The proposed method is easy to increase the power as parallel system in DC distribution. By improving conventional droop-control method used in AC grid newly, a droop controller is designed to apply droop control in DC grid. And the control method of the proposed droop controller is explained particularly. In this paper, by applying the proposed control method to DC distribution system, propriety is verified through the simulation and the experiment.

Advanced Droop Control Scheme in Multi-terminal DC Transmission Systems

  • Che, Yanbo;Zhou, Jinhuan;Li, Wenxun;Zhu, Jiebei;Hong, Chao
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1060-1068
    • /
    • 2018
  • Droop control schemes have been widely employed in the control strategies for Multi-Terminal Direct Current (MTDC) system for its high reliability. Under the conventional DC voltage-active power droop control, the droop slope applies a proportional relationship between DC voltage error and active power error for power sharing. Due to the existence of DC network impedance and renewable resource fluctuation, there is inevitably a DC voltage deviation from the droop characteristic, which in turn results in inaccurate control of converter's power. To tackle this issue, a piecewise droop control with DC voltage dead band or active power dead band is implemented into controller design. Besides, an advanced droop control scheme with versatile function is proposed, which enables the converter to regulate DC voltage and AC voltage, control active and reactive power, get participated into frequency control, and feed passive network. The effectiveness of the proposed control method has been verified by simulation results.

Design Optimization of Passive Control Devices for Dynamic Stall Control (동적실속 수동제어장치 최적설계)

  • Joo, Wan-Don;Lee, Bo-Sung;Yee, Kwan-Jung;Lee, Dong-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.1
    • /
    • pp.11-19
    • /
    • 2005
  • In order to improve dynamic stall characteristics of an oscillating airfoil, optimal design has been performed for fixed nose droop and Gurney flap. Fixed nose droop is known to be very effective to improve pitching moment characteristics but may cause degeneration of aerodynamic lift at the same time. On the other hand, Gurney flap has the opposite characteristics. For fixed nose droop, location and angle are chosen as design variables, while length is defined as design variable for Gurney flap. Higher order response surface methodology and sensitivity based optimal design method are employed to handle highly nonlinear problem such as dynamic stall. Optimal design has been performed so that lift and pitching moment are simultaneously improved. The design results show that aerodynamic characteristics can be remarkably improved through present design approach and the present passive control method is as good as active control method which combines variable nose droop and Gurney flap.

Droop Control for Parallel Inverers in Islanded Microgrid Considering Unbalanced Low-Voltage Line Impedances (마이크로그리드 독립 운전 모드시 저전압 불평형 선로 임피던스를 고려한 드룹 방식의 인버터 병렬 운전 제어 연구)

  • Lim, Kyung-Bae;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.387-396
    • /
    • 2013
  • This paper investigates the droop control of parallel inverters for an islanded mode of microgrid. Frequency and voltage droop control is one of power control and load demand sharing methods. However, although the active power is properly shared, the reactive power sharing is inaccurate with conventional method due to the unequal line impedances and the power coupling of active - reactive power. In order to solve this problem, an improved droop method with virtual inductor concept and a voltage and current controller properly designed have been considered and analyzed through the PSiM simulation. The performance of improved droop method is analyzed in not only low-voltage line but also medium voltage line.

The Improvement of Droop Characteristic of 780nm Monolithic 4-Beam Laser Diode (780nm Monolithic 4-Beam 레이저 다이오드의 Droop 특성 개선)

  • Hong, Hyun-Kwon;Kim, Ji-Ho;Ji, You-Sang;Seong, Yeong-Un;Lee, Sang-Don
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.285-287
    • /
    • 2009
  • When the laser diode is operated with continuous current, the light intensity from the laser diode deceases with time due to the temperature rise in the active layer. The phenomena, which is often called as DROOP, should be minimized in order to be used as a light source for the laser beam printer. We experimently examined the influences of the laser parameters such as threshold current, differential quantum efficiency on droop. It was found that decreasing the differential quantum efficiency of the laser diode is the effective way to minimize droop.

  • PDF

A Positioning Method of Distributed Power System by Considering Characteristics of Droop Control in a DC Microgrid

  • Ko, Byoung-Sun;Lee, Gi-Young;Kim, Sang-Il;Kim, Rae-Young;Cho, Jin-Tae;Kim, Ju-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.620-630
    • /
    • 2018
  • In this paper, a positioning method of distributed power system is proposed to minimize the average voltage variation of a DC microgrid through voltage sensitivity analysis. The voltage sensitivity under a droop control depends on the position of the distributed power system. In order to acquire a precise voltage sensitivity under a droop control, we analyzed the power flow by introducing a droop bus with the considerations of the droop characteristics. The results of the positioning method are verified through PSCAD/EMTDC simulation.