A Passive Lossless Soft-Switching Single Inductor Dual Buck Full-Bridge Inverter

  • Hong, Feng;Wu, Yu;Ye, Zunjing;Ji, Baojian;Zhou, Yufei
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.364-374
    • /
    • 2018
  • A novel passive lossless soft-switching single inductor dual buck full-bridge inverter (PLSSIDBFBI) is presented in this paper. To accomplish this, a passive lossless snubber circuit is added to a dual buck full-bridge inverter. Therefore, the advantages of the dual buck full-bridge inverter are included in the proposed inverter, and the inverter has just one filter inductor, which can decrease the system volume and improve the integration. In addition, the passive lossless snubber circuit achieves soft-switching by its own resonance, and all of the energy stored in the passive lossless snubber circuit can be transferred to load. A comparison between eight topologies is performed in this paper, and the analysis shows that the proposed soft-switching inverter topology has high reliability and efficiency. Finally, experimental results obtained with a 1 kW prototype verify the theoretical analysis and demonstrate the prominent characteristics of a reduced switching loss and improved efficiency.

High-Reliability Three-Phase Dual-Buck Grid-Connected Inverter without Shoot-Through Problem

  • Fu, Zhenbin;Feng, Zhihua;Chen, Xi;Zheng, Xinxin
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.454-462
    • /
    • 2019
  • When compared to traditional bridge-type inverters, the dual-buck inverter has a higher reliability due to the fact that its bridge legs do not have a shoot-through problem. In this paper, the working principle of the dual-buck inverter is analyzed. A comparison of the working modes under full-cycle and half-cycle control is discussed. With half-cycle control, the inverter can realize a higher efficiency. However, this results in current zero-crossing distortion. The corresponding control strategy of the dual-buck inverter is proposed in order to realize both high efficiency and low current harmonic distortion. In addition, the system stability is analyzed. Dead-time is unnecessary due to the advantages of the topology. Thus, the current harmonic distortion can be further reduced. An inverter with the proposed control strategy has the advantages of high reliability, high efficiency and low current harmonic distortion. Finally, simulation and experimental results are given to verify the theoretical analysis.

A Novel Five-Level Flying-Capacitor Dual Buck Inverter

  • Liu, Miao;Hong, Feng;Wang, Cheng-Hua
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.133-141
    • /
    • 2016
  • This paper focuses on the development of a Five-Level Flying-Capacitor Dual Buck Inverter (FLFCDBI) based on the main circuit of dual buck inverters. This topology has been described as not having any shoot-through problems, no body-diode reverse recovery problems and the half-cycle work mode found in the traditional Multi-Level Flying-Capacitor Inverter (MLFCI). It has been shown that the flying-capacitor voltages of this inverter can be regulated by the redundant state selection within one pole. The voltage balance of the flying-capacitors can be achieved by charging or discharging in the positive (negative) half cycles by choosing the proper logical algorithms. This system has a simple structure but demonstrates improved performance and reliability. The validity of this inverter is conformed through computer-aided simulation and experimental investigations.

Alleviate Current Distortion of Dual-buck Inverter During Reactive Power Support (듀얼벅 인버터의 무효전력 보상 시 전류 왜곡 저감)

  • Han, Sanghun;Cho, Younghoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.134-141
    • /
    • 2022
  • This study presents a method for reducing current distortion that occurs when a dual-buck inverter generates reactive power. Dual-buck inverters, which are only capable of unity power factor operation, can generate reactive power capabilities by modifying a modulation technique. However, under non-unity power factor conditions, current distortion occurs at zero-crossing points of grid voltage and output current. This distortion is caused by parasitic capacitors, dead-time, and discontinuous conduction mode operation. This study proposes a modified modulation method to alleviate the current distortion at zero-crossing point of the grid voltage. A repetitive controller is applied to reduce this distortion of the output current. A 1 kVA prototype is built and tested. Simulation and experimental results demonstrate the effectiveness of the proposed method.

High-Efficiency Dual-Buck Inverter Using Coupled Inductor (결합 인덕터를 이용한 효율적인 단상 듀얼-벅 인버터)

  • Yang, Min-Kwon;Kim, Yu-Jin;Cho, Woo-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.6
    • /
    • pp.396-405
    • /
    • 2019
  • Single-phase full-bridge inverters have shoot-through problems. Dead time is an essential way of solving these issues, but it distorts the output voltage and current. Dual-buck inverters are designed to eliminate the abovementioned problems. However, these inverters result in switching power loss and electromagnetic interference due to the diode reverse-recovery problem. Previous studies have suggested reducing the switching power loss from diode reverse-recovery, but their proposed methods have complex circuit configurations and high system costs. To alleviate the switching power loss from diode reverse-recovery, the current work proposes a dual-buck inverter with a coupled inductor. In the structure of the proposed inverter, the current flowing into the original diode is divided into a new diode. Therefore, the switching power loss is reduced, and the efficiency of the proposed inverter is improved. Simulation waveforms and experimental results for a 1.0 kW prototype inverter are discussed to verify the performance of the proposed inverter.

Dual Buck Half-Bridge Inverter with Zero Voltage Switching (ZVS를 이용한 DB하프브리지 인버터 구현 방법)

  • Park, Chong-Yun;Lim, Ki-Seung;Sin, Dong-Seok;Choe, Hyeon-Hui
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.756-762
    • /
    • 2009
  • This paper proposes a high efficient Dual Buck Inverter design with a zero voltage switching (ZVS) control technique. The ZVS control is realized by adding a feedback loop circuit which is implemented by simple RS latch and TTL gate. The used load was 200W -Ceramic Metal Halide Lamp. The experimental results show that the proposed Inverter system could avoid the acoustic resonance and achieve high efficiency by Zero Voltage Switching.

Half Load-Cycle Worked Dual Input Single Output DC/AC Inverter

  • Chen, Rong;Zhang, Jia-Sheng
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1217-1223
    • /
    • 2014
  • A novel half load-cycle worked dual input single output (DISO) DC/AC inverter is presented. The basic circuit consists of a dual buck regulator, which works in continuous current mode. The working principle of DISO DC/AC inverter has been used. The control method applied for half load-cycle worked DISO DC/AC inverter has been studied. The control effects of the open-loop proportional control and closed-loop proportional-integral control are compared by using PSIM software. The parameters are adopted in the realistic simulation and experiment test. Moreover, the waveforms, such as voltage of modulation reference signal and output voltage, were given. The simulation and experiment results proved that the half load-cycle worked DISO DC/AC inverter could achieve good performance, gain a line frequency of 50 Hz, and verify the correctness of theoretical analysis.

Analysis of voltage controller of Dual-Buck Inverter using Redox Flow Battery (RFB 용 Dual-Buck Inverter 전압제어 품질 향상에 관한 연구)

  • Choe, Jung-Muk;Cho, Younghoon;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.393-394
    • /
    • 2014
  • This paper proposes advanced RFB PCS for islanded environment. To accommodate islanded system, power conditioning needs voltage control authority changing. Dualbuck inverter topology is designed for the high efficiency. In order to reduce voltage error the repetitive controller is used in this paper. The control performance has been verified with computer simulation.

  • PDF

Modified Dual-Buck Inverter Based on Resonant Link

  • Chen, Rong;Zhang, Jia-Sheng;Liu, Wei
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1421-1428
    • /
    • 2015
  • The efficiency and reliability of the dual-buck inverter (DBI) were greatly improved by eliminating the shoot-through problem and optimally designing the freewheeling diode. The traditional DBI suffers from large harmonic components with low output voltage and large capacity output filter inductor. To overcome the aforementioned disadvantages, a modified DBI (MBDI) was proposed by adopting a quasi-resonant link and pulse density modulation (PDM). This paper first introduces the working principle of the MBDI and PDM, and then the selection principle of system parameters is presented. Finally, a mathematical model of the MBDIis built, and an experiment prototype is set up. Simulation and experimental results verify the correctness of the theoretical analysis and the feasibility of the scheme.

A Dual Buck Three-Level PV Grid-Connected Inverter

  • Ji, Baojian;Hong, Feng;Wang, Jianhua;Huang, Shengming
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.910-919
    • /
    • 2015
  • The use of a PV grid-connected inverter with non-isolated topology and without a transformer is good for improving conversion efficiency; however, this inverter has become increasingly complicated for eliminating leakage current. To simplify the complicated architecture of traditional three-level dual buck inverters, a new dual Buck three-level PV grid-connected inverter topology is proposed. In the proposed topology, the voltage on the grounding stray capacitor is clamped by large input capacitors and is equal to half of the bus voltage; thus, leakage current can be eliminated. Unlike in the traditional topology, the current in the proposed topology passes through few elements and does not flow through the body diodes of MOSFET switches, resulting in increased efficiency. Additionally, a multi-loop control method that includes voltage-balancing control is proposed and analyzed. Both simulation and experimental results are demonstrated to verify the proposed structure and control method.