• Title/Summary/Keyword: Duct

Search Result 2,377, Processing Time 0.031 seconds

Investigation of Pressure Loss in Bent Duct (Bent Duct 내부 유동의 손실 측정)

  • Roh, U-Jin;Im, Ju-Hyun;Song, Seung-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.295-298
    • /
    • 2009
  • Bent ducts add loss and decrease efficiency. Many researchers have been conducted the performances of bent ducts, but their shapes of inlet and outlet are same. However, in this investigation, the focus is on a bent duct which is annular at the inlet and circular at the outlet. The bent duct of these complex shapes has not been investigated, but has been used in many fields. The performance of such bent duct is investigated under inlet speed 54 m/s and Re = 238,000. Wall static pressure tappings are located surface of the bent duct to measure the static pressure and a probe is traversed at the inlet and outlet of the bent duct to measure the total pressure. As a result, it presents static pressure distribution on the bent duct surface, streamwise velocity profile at inlet and outlet of the bent duct and total pressure loss profile at outlet. In this investigation, the total pressure loss coefficient is 0.243.

  • PDF

Analysis of loop duct system by extended T-method (확장 T-method에 의한 환상식 덕트시스템 해석)

  • 이승철;문종선;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.389-397
    • /
    • 1998
  • A loop duct system is often found in a VAV-HVAC(variable air volume heating, ventilating and air conditioning) design. It is known that the simple T-method is not be applicable to the loop duct system and cannot be used to calculate the flow rate and the pressure drop at each duct section of the loop duct system. In this paper, the extended T-method has been developed and it is found to be applicable to the loop duct system to which the simple T-method cannot be applied. The validity of the extended T-method has been verified by using to solve for a simple, ideal loop duct system for which there exists analytical solution. In addition, the extended T-method is employed to compute the loop duct system of a real building with an area of 380$m^2$. The results show that the computed flow rate at the exit differs from the designed flow rate by a range of -13.6~43.5 %. Consequently, three design factors must be adjusted in order that the flow rate may be balanced. These include the duct sizes, in terms of their lengths and diameters, the sub-duct locations and the positioning of damper which is found upstream of the exit duct.

  • PDF

Ultrastructural Changes of the Hermaphrodite Duct Epithelium by Season in a Korean Slug Incilaria fruhstorieri (한국산 산민달팽이(Incilaria fruhstorferi) 장웅동체관 상피의 계절에 따른 미세구조의 변화)

  • 장남섭;정계헌
    • The Korean Journal of Zoology
    • /
    • v.39 no.2
    • /
    • pp.139-146
    • /
    • 1996
  • A studv on the ultrastructural changes of the hermaprodite duct epithelium in spring and summer specimens of a Korean slug Incirovia fruhstorferi was conducted. In spring specimen, the hermaphrodite duct was 0.3 H 0.2 mm in diameter and seemed to be a little bit abnormal feature, due to shrinkage. The epithelium of the duct was composed of cells containing various-sized vacuoles and their cytoplasm showed high electron density. In summer specimen, the hermaphrodite duct was 0.4 $\times$ 0.23 mm in diameter and seemed to be more voluminous than that of the spring specimen. The lumen of the duct in the summer specimen was lined by a epithelium composed of several cell types such as ciliated cuboidal, pseudostratified cuboidal, ciliated columnar and irregular cells. Phasocvtotic activities of the duct epithelium are observed only in the summer specimen. Both of the duct epithelia in the spring and summer specimens were surrounded by connective tissues at their bases. The results obtained suggest that the duct epithelia of the slugs experience seasonal variation in relation to their reproductive cycles.

  • PDF

Fragmentation of Common Bile Duct and Pancreatic Duct Stones by Extracorporeal Shock-wave Lithotripsy (체외충격파쇄석술을 이용한 총담관 및 췌관 결석의 치료)

  • Kim, Ham-Gyum;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.40-45
    • /
    • 1998
  • To determine its usefulness and safety of extracorporeal shock-wave lithotripsy in common bile duct and pancreatic duct stones, we analyzed the results of 13 patients with common bile duct stones and 6 patients with pancreatic duct stones which were removed by endoscopic procedures using the balloon or basket, who was performed the extracorporeal shock-wave lithotripsy using the ultrasonography for stone localization with a spark gap type Lithotriptor(Dernier MPL 9000, Germany). Fragmentation and complete clearance of the common bile duct and pancreatic duct stones were obtained in 19 of 19 patients(100%). Apart from transient attacks of fever in 2 of 13 patients with common bile duct stones(15%) and mild elevation of serum amylase and lipase in 2 of 6 patients with pancreatic duct stones(33%), no other serious side effects were observed. In our experiences, extracorporeal shock-wave lithotripsy is a safe and useful treatment for endoscopically unretrievable common bile duct and pancreatic duct stones.

  • PDF

A study on optimization of duct shape of electric hubless rim-driven propeller (전기구동 림 추진기의 덕트 형상 최적화 연구)

  • Yong-beom PYEON;Jae-Hyun BAE;Hyoung-Ho KIM;Chang-Je LEE
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.1
    • /
    • pp.65-73
    • /
    • 2023
  • This study analyzed the duct characteristics of hubless rim-driven propeller (RDP) used in underwater robots. In the previous study, flow visualization experiments were performed with an advancing ratio of 0.2 to 1. The vortex at the front of the duct increased in strength while maintaining its size as the advancing ratio decreased. Therefore, it is necessary to study the optimization of the duct shape. Conventional propeller thrusters use acceleration/deceleration ducts to increase their efficiency. However, unlike conventional propellers, it is impossible to apply to airfoil acceleration/deceleration ducts due to the RDP structure. In this study, duct wake flow characteristics, thrust force, and efficiency according to the duct shape of RDP were analyzed using numerical analysis techniques. Duct design is limited and six duct shapes were designed. As a result, an optimized duct shape was designed considering duct wake flow characteristics, thrust force, and efficiency. The shape that the outlet width of the RDP was kept constant until the end of the duct showed higher thrust force and efficiency.

Acoustic Analysis of a Duct with Mean Flow by Use of FEM (유한요소법을 이용한 유체속도가 고려된 덕트의 음향특성 해석)

  • 서영수;정의봉;윤상돈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1026-1031
    • /
    • 2002
  • This paper shows the effect of mean flow in duct. The potential equation of duct with mean flow is obtained. A finite element method(FEM) is used to predict acoustic performance of duct with mean flow. The formulation of the finite element method is derived for duct taking into consideration of the convective effect of mean flow. A simple duct, simple expansion chamber and a duct with resonator are implemented to show the effects of the mean flow.

  • PDF

A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers: Inlet Vortex Induced Excessive Vibration (화력 발전용 보일러 Duct/Fan 시스템의 진동현상에 대한 연구 : Inlet Vortex에 의한 과대진동 사례)

  • Kim, Cheol-Hong;Ju, Young-Ho;Byun, Hyung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.82-87
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

A Study for the Design of the Air-Conditioning Duct of Korean High Speed Train (한국형 고속전철의 에어컨 덕트 설계를 위한 연구)

  • 이승민;박철희;이우식
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.479-486
    • /
    • 1999
  • The noises generated from the air-conditioning duct are known to strongly affect the indoor-noises of high speed trains. The acoustic characteristics of an air-conditioning duct should depend on the geometry and shape of the duct. The structural material for Korean high speed train is supposed to be changed from Steel, which was used for TGV, to Aluminum in order to reduce the total train weight. Accordingly, the shape and layout of the air-conditioning duct of Korean high speed train will be different from that of TGV. Thus, this paper introduces a analytical method to predict the noise attenuation through the air-conditioning duct, based on the ISO 7235. In this method, the whole duct is divided into several pieces and the noise attenuations predicted for each duct piece are integrated to get the noise attenuation for the whole duct system. The validity of the method introduced herein is discussed through some numerical tests.

  • PDF

Effects of Bupleuri Radix on Rat Hepatic MAO by Common Bile Duct Ligation and Taurocholate Load after Common Bile Duct Ligation (시호(柴胡)가 총담관결찰 및 taurocholate 부하(負荷) 흰쥐 간의 MAO 활성에 미치는 영향)

  • Kim, Seong-Mo;Wang, Wu-Hao;Park, Jae-Hyun
    • The Journal of Internal Korean Medicine
    • /
    • v.21 no.2
    • /
    • pp.275-281
    • /
    • 2000
  • Object : This study was carried out to examine the effect of Bupleuri Radix on experimental cholestasis, and make clear apart of this mechanism. Methods : Two models of common bile duct ligation group and taurocholate load group after common bile duct ligation were induced, and Bupleuri Radix extract was taken orally for 14 days. In the 1, 2, 4, 7 and 14 days after treatment, the mitochondrial and microsomal monoamine oxidase(MAO) A and B activities in liver were measured. Results : The mitochondrial MAO A and B activities increased in both Blupleuri Radix treated group after common bile duct ligation and Blupleuri Radix treated group after taurocholate load and common bile duct ligation. MAO A increased in Blupleuri Radix treated group after taurocholate load and common bile duct ligation, and MAO B increased in Blupleuri Radix treated group after common bile duct ligation. The microsomal MAO A activities increased in both Blupleuri Radix treated group after common bile duct ligation and Blupleuri Radix treated group after taurocholate load and common bile duct ligation. Conclusion : According to the result, it is consider that Blupleuri Radix not only improves cholestatis in liver, but also decreases a genetic synthesis of taurocholic acid.

  • PDF

Improving the Distribution of Temperature by a Double Air Duct in the Air-Heated Plastic Greenhouse (시설내 온도분포 균일화를 위한 온풍난방기용 2중 덕트개발)

  • 김태영;김기덕;조일환;남은영;남윤일;우영회;문보흠
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.162-166
    • /
    • 2004
  • Air temperature variation along the length of the air duct in an air-heated plastic greenhouse was large, 13 ~ 15$^{\circ}C$ between the front and the rear side of a greenhouse. To reduce this temperature variation, a new PE-film air duct having a small duct inside a large duct (double duct) was developed. This double duct was consisted of an inner duct with air outlets at a 0.15 m interval and an outer duct with air outlets at a 2.5 m interval. Diameters of the air outlet holes were 7, 15, and 35 cm from the front to the end of the inner duct film, while identical 10 cm holes were used on the outer duct film. As a result, air temperature was $46^{\circ}C$ at the beginning side and $47^{\circ}C$ at the ending side, while the conventional single duct had $53^{\circ}C$ at the beginning point and $38^{\circ}C$ at the ending point with a variation of $15^{\circ}C$. Height of a cucumber crop grown in a greenhouse with the new double air duct system was 65.5 cm, 14% increase as compared to that in a greenhouse with a conventional air duct system. Total fruit yield per l0a greenhouse in a greenhouse with the new double air duct system was 4,616 kg, which was 17% greater than that in a greenhouse with a conventional air duct system. Amount of heating oil consumption during March 3 to April 24, 2002 was 3,233 L per l0a greenhouse with the new double air duct system, which was 13% less than that with a conventional air duct system.