• Title/Summary/Keyword: Dust proof

Search Result 19, Processing Time 0.027 seconds

Functional Finishing of Nonwoven Filter for Dust-proof/Medical Masks by Corona Discharging Treatment (코로나 방전에 의한 방진/의료용 마스크 여과재의 기능화 가공)

  • Hong, Young-Ki
    • Textile Coloration and Finishing
    • /
    • v.25 no.3
    • /
    • pp.232-239
    • /
    • 2013
  • In this study, 25gsm melt-blown polypropylene nonwoven for dust-proof/medical masks was finished by the corona discharging treatment. The influence of corona discharging parameters on the filtration efficiency was investigated. Several parameters such as discharging voltage, discharging speed, distance to discharging wire and configuration of discharging system had an effect on filtration efficiency, while the parameters had no effect on breathing resistance. Optimum corona discharging conditions are as follows: Wires were installed on the upper part of the nonwoven and paper pipe was installed on the lower part of the nonwoven having a distance of 5cm. The sequence of wire voltages was +60 kV, +60 kV, 0, -60 kV, and -60 kV. The discharging voltage and speed were 60 kV and 30m/min respectively. The nonwoven treated by corona discharging at the optimum condition showed a filtration efficiency of 80% or more, which is suitable for dust-proof/medical masks.

Study of Development of a Dust-proof Oil Cooler (내분진형 오일 쿨러 개발에 관한 연구)

  • Lee, Young-Lim;Jeon, Euy-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.60-65
    • /
    • 2008
  • A typical louvered-fin oil cooler can be easily contaminated under dusty environment hence resulting in poor performance of a heat exchanger. Thus, in this study, a dust-proof oil cooler has been studied with a unique shape of a 3-dimensional wavy fin since non-louvered fins could have better performance under dusty environment compared to louvered fins. Recently, they have been introduced to commercial and constructional vehicles in Japan. At first numerical analysis has been done to optimize the angle of the wavy fin so that the oil cooler developed can satisfy the target performance. The wavy fin has been then made with roll-forming and roll-pitch stands, and a prototype of an oil cooler with the wavy fin has been finally built with brazing. The performance test showed that the heat release rate of the oil cooler was well beyond the target, 4.94kW and the air-side pressure drop was below the criterion, 0.19kPa. In addition, the results showed that the numerical prediction was effective enough to design the dust-proof oil cooler that satisfies the performance criteria.

COSMIC DUST AND COSMOLOGY

  • PREVENSLIK, THOMAS V.
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.327-330
    • /
    • 2015
  • Cosmology considers the Hubble redshift of galaxy light by the Doppler effect as proof the Universe has been expanding since the Big Bang. However, cosmic dust that permeates the Universe also redshifts galaxy light that if not corrected over-predicts the velocities of all astronomical measurements inferred by the Doppler effect. Hubble redshifts corrected for cosmic dust suggest the Universe may not be expanding, the consequence of which may allow the outstanding problems in cosmology to possibly be resolved by Newtonian mechanics.

A Study of Dust Effect on Performance of Heat Exchangers with Louver and Wavy Fins (루버형과 파형핀 열교환기에서 분진이 성능에 미치는 영향에 관한 연구)

  • Lee, Young-Lim;Hwang, Soon-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.4
    • /
    • pp.126-132
    • /
    • 2009
  • Automotive heat exchangers use louver fins for their high efficiency. However, the efficiency can significantly drop for constructional vehicles or heavy equipments due to dust deposited on the louver fins with narrow slits. Thus it is necessary to develop new fins that lead to less fouling, so that a better performance can be achieved after exposure to a dusty environment over long period of time. New wavy fins were considered in the study and numerically analysed to compare with louver fins in the areas of air-side pressure drop, heat release rate, and particulate deposition. In addition, an experiment was done on the pressure drop and the particulate deposition. The results showed that the wavy fins would be a better choice for long-term use due to the excellent dust-proof performance in comparison to louver fins, in spite of the initial inferior performance of heat release.

Development of SWIR 3D Lidar System with Low Optical Power Using 1 Channel Single Photon Detector (1채널 단일광자검출기를 이용한 낮은 광출력의 SWIR(Short Wave Infrared) 3D 라이다 시스템 개발)

  • Kwon, Oh-Soung;Lee, Seung-Pil;Shin, Seung-Min;Park, Min-Young;Ban, Chang-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_3
    • /
    • pp.1147-1154
    • /
    • 2022
  • Now that the development of autonomous driving is progressing, LiDAR has become an indispensable element. However, LiDAR is a device that uses lasers, and laser side effects may occur. One of them is the much-talked-about eye-safety, and developers have been satisfying this through laser characteristics and operation methods. But eye-safety is just one of the problems lasers pose. For example, irradiating a laser with a specific energy level or higher in a dusty environment can cause deterioration of the dust particles, leading to a sudden explosion. For this reason, the dust ignition proof regulations clearly state that "a source with a pulse period of less than 5 seconds is considered a continuous light source, and the average energy does not exceed 5 mJ/mm 2 or 35 mW" [2]. Energy of output optical power is limited by the law. In this way, the manufacturer cannot define the usage environment of the LiDAR, and the development of a LiDAR that can be used in such an environment can increase the ripple effect in terms of use in application fields using the LiDAR. In this paper, we develop a LiDAR with low optical power that can be used in environments where high power lasers can cause problems, evaluate its performance. Also, we discuss and present one of the directions for the development of LiDAR with laser power limited by dust ignition proof regulations.

Awareness of occupational hazards and personal protective equipment use among dental hygienists

  • Choi, Hyun-Ju;Hwang, Tae-Yoon;Jeon, Man-Joong
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.1
    • /
    • pp.20-25
    • /
    • 2019
  • Background: The aim of this study was to evaluate the awareness of occupational hazards and personal protective equipment use among dental hygienists (DHs). Methods: A total of 271 self-administered questionnaires were obtained from 280 DHs working at dental hospitals or clinics in Daegu and Gyeongsangbuk-do, Korea. Results: The occupational hazards included work involving dust (94.1%), volatile substances (86.0%), noise (97.0%), and light-curing units (96.7%). The proportion of dental hygiene tasks that participants perceived as harmful were 42.4%, 51.7%, 9.2%, and 31.4% in the same order as above. The proportion of participants who used dust-proof masks during work involving dust was 1.1%. Those who wore gas-proof masks and gloves for work using volatile substances were 0.7% and 31.2%, respectively. Participants who used goggles for work involving light-curing units were 31.0%. None of the participants used ear plugs for work involving noise. A total of 22.9% of the participants recognized the Material Safety Data Sheet, while 79.7% had never been educated about harmful work environments. Conclusion: When compared to exposure status and perception of occupational hazards, the level of protective equipment use was very low. Extra measures to increase DHs' use of personal protective equipment are necessary.

Development of Cleanroom Garment Design in Semiconductor Industrial Environment (반도체 산업환경에서의 방진복 디자인의 개발)

  • 이윤정;정찬주;정재은
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.2
    • /
    • pp.337-348
    • /
    • 2002
  • Based upon literature survey and questionnaire survey, this research tries to develop four new Cleanroom Garment in semiconductor industrial environment. The designs emphasize to minimize workers disconmfort so that they can not only cover human body fully but also reduce dust as much as possible during work hour in clean room. The new designs characteristics and results from both function test and dust emission test are as follows: 1. In order to reduce dust-emission, we develop new designs with hood, kimono sleeve, and back zipper. The designs with hood face positive test results in term of motion suitability and dust-omission. The design with seam in front, in particular, is effective to control dust-emission. 2. For the purpose of reducing dust-emission, we also emphasize to minimize ease of dust-proof wear, with reference to previous research and clothing experiment. The experiment participants report that the new wears are not so comfortable as existing ones, but they accept the new wears positive as effective in reducing dust-emission owing to reduced ease of Cleanroom Garment and sleeves. 3. A1so to reduce dust-emission in inner wear, we put inner wear in both Cleanroom Garments and inner wear, resulting to remove discomfort of wearers when changing clothes and of tight waist due to inner-trousers. 4. We develop new designs with elastic bands in both waist through the side lines and with velcro only at the back side. To remove twist in front contributes to reduce emission arising out of friction, also to free the appearance minding woman workers from worrying about exposed stomach. The new designs need to be accepted as a valuable alternative of Cleanroom Garment, in that they are highly effective to reduce dust-emission, which is the most important factor in the wear, in spite of some drawbacks in terms of motion-suitability, ease and appearance as shown in wearing test.

A Study on the Development of Explosion Proof ESD Detector and Intrinsic Safety Characteristics Analysis (방폭구조 ESD Detector 개발 및 본질안전 특성 분석에 관한 연구)

  • Byeon, Junghwan;Choi, Sang-won
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.1
    • /
    • pp.1-11
    • /
    • 2020
  • Article 325 (Prevention of Fire Explosion due to Electrostatic) of the Rule for Occupational Safety and Health Standard specifies that in order to prevent the risk of disasters caused by static electricity, fire, explosion and static electricity in the production process, However, in order to do this, it is absolutely necessary to use a pre-detection technology and a detector for antistatic discharge prediction, which is a precautionary measure by static electricity in a fire / explosion hazard place, but in Korea, And there is no technical standard for the application of the technology of the explosion proof structure of the related equipment. Research methods include domestic and overseas electrostatic discharge detection technology and literature investigation of related equipment explosion proofing technology, domestic and foreign electrostatic discharge detection device production and use situation investigation, advanced foreign technology data analysis and benchmarking. In particular, we sought to verify the results of empirical experiments using electrostatic discharge detection technology through sample purchase and analysis of related major products, development of optimization technology through prototype production, evaluation, and supplementation, and expert knowledge through expert consultation. The results of this study were developed and fabricated two prototypes of electrostatic discharge detector based on the technology / standard related to electrostatic discharge detection technology in Korea and abroad through development of electrostatic discharge detection technology and development and production of detector. In addition, based on the development of electrostatic discharge detection technology, we developed an intrinsic safety explosion proof ib class explosion proof technology applicable to the process of using and handling flammable gas and flammable liquid vapor and combustible dust. In the case of the over voltage and minimum voltage are supplied to the explosion-proof structure ESD detector, check the state of the circuit and the transient and transient currents generated by the coil and capacitor elements during the input and standby of the signal pulse voltage. Explosion-proof equipment-Part 11: Intrinsically safe explosion proof structure The comparative evaluation with the reference curve in Annex A of "i" confirms that the characteristics of the intrinsically safe explosion protection structure are met.

Effectiveness of education for control of house dust mites and cockroaches in Seoul, Korea

  • JEONG Kyoung Yong;LEE In-Yong;LEE Jongweon;REE Han-Il;HONG Chein-Soo;YONG Tai-Soon
    • Parasites, Hosts and Diseases
    • /
    • v.44 no.1 s.137
    • /
    • pp.73-79
    • /
    • 2006
  • We evaluated the efficacy of health education in reducing indoor arthropod allergens in Seoul. The mite control measures comprised the use of mite-proof mattress and pillow coverings, regular washing of potentially infested materials, maintenance of a low humidity, removal of carpets, and frequent vacuum cleaning. Cockroach control measures included trapping, application of insecticides, and protecting food. Of 201 homes enrolled in October 1999, 63 volunteers were included in a 2-year follow-up survey between April 2000 and January 2002. Before intervention, the density of mites/g of dust varied greatly; 27.1/g in children's bedding, 20/g in adult bedding, 7.2/g on the floors of children's bedrooms, 6.8/g in sofas, 5.9/g on the floors of adult's bedrooms, 3.9/g on living room floors, 3.7/g in carpets, and 1.9 mites/g on kitchen floors. The predominant mite species and house percentages infested were; Dermatophagoides farinae $93\%$, D. pteronyssinus $9\%$, and Tyrophagus putrescentiae $8\%$. Comparing 1999 and 2001 infestations, before and after 25 mo of education, mite abundance was reduced by $98\%$, from 23.7 to 0.57 mites/g of dust. In 1999, cockroaches were detected in $62\%$ homes: $36\%$ Blattella germanica and $35\%$ Periplaneta spp., including $9\%$ double infestations of B. germanica and P. americana. Following intervention, cockroach infestation rates decreased to $22\%$ of houses in 2000 and $23\%$ in 2001. We conclude that continuous and repetitive health education resulted in the effective control of domestic arthropods.

Aerodynamic acoustics of automotive weather strip protuberance (풍절소음 저감을 위한 웨더스트립 돌출부 형상연구)

  • Kim, Tae-Hoo;Lee, Gye-Ho;Jeon, Seung-Gyeong;Hwang, Jung-Ho;Kim, Joon-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2546-2551
    • /
    • 2007
  • Weather Strip(W/S) is a rubber part to proof water, sound and dust for opening and shutting devices including vehicle doors. And it requires high dimension precision and durability to proof water, noise, vibration and etc. But ironically it itself makes some wind noise because of some protuberance with glasses. The air flow analysis of door part of vehicle makes it possible to calculate and find out the cause of wind noise. In previous analysis, we focus on the numerical air flow analysis of the automobile side part. We do 2D-C.F.D first and 3D second. Through simulations, we can calculate the amount of sound pressure level at the glass run and find out the effects of glass run to make wind noise. Finally we can improve shape of glass run to reduce wind noise although it is small amounts of sound pressure reduction compared with total vehicle noise level.

  • PDF