• Title/Summary/Keyword: E-PERM

Search Result 12, Processing Time 0.03 seconds

Microwave Radiation Effects on the Process of Escherichia coli Cultivation

  • Kuznetsov, Denis;Volkhin, Igor;Orlova, Ekaterina;Neschislyaev, Valery;Balandina, Alevtina;Shirokikh, Anna
    • Microbiology and Biotechnology Letters
    • /
    • v.47 no.3
    • /
    • pp.372-380
    • /
    • 2019
  • Modern biotechnological industries have been attempting to improve the efficiency of bacterial strain cultivation. Millimeter wave electromagnetic radiation can have a varied influence on E. coli cultivation processes. The results of the study revealed that when a microwave radiation of low intensity is applied to positively adjust the conditions for the accumulation of bacterial culture biomass, a significant role is played not only by radiation parameters, but also by concomitant biological factors, which influence the reproducibility of the cultivation process and help obtain a useful biotechnological effect. The authors suggest a model that can be used to study the molecular mechanisms underlying the changes in the buildup of E. coli biomass under the influence of electromagnetic radiation.

Performance Evaluation of Several Radon Detectors in the Standard Chamber and Dwellings (라돈 표준실과 가옥 내에서 일부 라돈검출기에 대한 성능 평가)

  • Yoon, Seok-Won;Kim, Yong-Jae;Chang, Byung-Uck;Byun, Jong-In;Yun, Ju-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.173-181
    • /
    • 2008
  • To ensure the performance of radon detectors, three passive radon detectors ($RadTrak^{(R)}$, $Radopot^{(R)}$, and $E-PERM^{(R)}$)have been reviewed. The difference ratios of RadTrak and Radopot tested in the radon standard chamber were -13.2% and -6.0%, respectively, which were in good accordance within 20% of the value measured by $AlphaGUARD^{(R)}$. To ensure the performance of the long term measurement, the 3 detectors were installed at the same position of approximately one hundred of dwellings for one year. The correlation curve between RadTrak and Radopot shows good agreement with a correlation coefficient ($R^2$) of 0.91. However, The correlation curve between E-PERM and Radopot shows bad agreement ($R^2$ = 0.021). In addition, the distribution map of annual mean indoor gamma dose rate measured with E-PERM was not in accordance with the distribution map of outdoor gamma dose rate measured by Portable Ion Chamber. According to the results, some requisites for the selection of the radon passive detectors in the large-scale indoor radon survey were discussed.

A Study on Indoor Radon Concentrations in Urban Area (도시 일부지역에서의 실내 라돈농도에 관한 연구)

  • 김순애;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.89-98
    • /
    • 2002
  • This study was taken in general hospital, hotel, shopping center, underground cafe, school, house, for the purpose of investigating the distribution of indoor radon concentration in urban area, by E-PERM which approved U.S. EPA, between August and November 1999. There are two sampling Places were exceed 148 ㏃/㎥(4 pCi/L; U.S EPA remedial level), difference mean is 24.0㏃/㎥ when compared with underground vs. aboveground indoor radon concentration in the same building and ratio is 1.6, so underground area is higher than aboveground (p<0.05). Influencing factors were examined. They related to the location of sampler(detector) open or near the door is lower radon concentration than inside portion, which explains probably open area has better ventilated air and dilutes indoor radon concentration. Temperature has a negative relationship (p<0.05) with indoor radon concentration and relative humidity has a positive (p<0.05) Simultaneously to investigate water radon concentration, collected piped-water and the results were very low, which is the same in piped-water concentration other countries. In conclusion, underground indoor radon concentration is higher than aboveground. Concentration was related to sampling spot, open portion is lower than inside. Higher the temperature, lower the indoor radon concentrations. On the other hand higher the relative humidity, higher the indoor radon concentrations. Indoor radon concentration is influenced by sampling point, temperature, relative humidity.

A Study on Indoor Radon Concentration among Vulnerable Households in Korea (국내 라돈 취약가구에 대한 주거공간의 실내 라돈 농도에 관한 연구)

  • Zoo, Duck Hyun;Park, Ki Ho;Jeong, Hui Won;Lim, Hyeong Jun;Bok, Dong Seok;Yun, Dong Won;Min, Kyung Hwan;Mun, Kyung Deok;Kim, Jeong Un;Lee, Ji Min;Choi, Won Yong;Kim, Sung Yoon
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.61-70
    • /
    • 2015
  • Objectives: The purpose of this research was to examine radon exposure in terms of the relationship between the living environment and indoor radon concentrations among vulnerable households. Methods: Nationwide, 1,129 subjects were selected using personal questionnaires for adequately understanding the living environment, installation of E-PERM radon gas detectors, and investigation of the structure of the housing. Results: The mean concentration of indoor radon for all subjects was $130.2Bq/m^3$ (GM=101.7), and a total of 438 subjects (38.8%) exceeded the recommended standards ($148Bq/m^3$) for public facilities by the Ministry of the Environment. By location, the highest concentrations ($164.3Bq/m^3$, GM=124.1) were seen in North Chungcheong Province. In the case of the Seoul/Gyeonggi Province metropolitan area, they showed $125.6Bq/m^3$ (GM=105.1) and $118.9Bq/m^3$ (GM=96.5), respectively. By type of housing, indoor radon concentrations in single-family housing were higher than in row/multi-family housing (p<0.01). Although indoor radon concentrations raised in accordance with year of construction (p<0.05), the difference between indoor radon concentrations in underground residences was not observed to be statistically significant (p=0.633). Conclusion: More studies are necessary in the future regarding the difference in indoor radon concentrations that may occur due to different of types of indoor construction, building materials, and the amount of building materials.

Repairing Damaged Hair Using Pentapeptides of Various Amino Acid Sequences with Crosslinking Reaction

  • Choi, Wonkyung;Son, Seongkil;Song, Sang-Hun;Kang, Nae Gyu;Park, Sun-gyoo
    • Korea Journal of Cosmetic Science
    • /
    • v.2 no.1
    • /
    • pp.11-19
    • /
    • 2020
  • The aim of this study is to investigate the effect of various pentapeptides on hair repair depending on the characteristics of comprising amino acids using crosslinking agents in hair. Total ten peptides were synthesized with two kinds of amino acids respectively, of which were previously categorized according to R group of the amino acids contributing to the characteristic of each peptide: STTSS (Ser-Thr-Thr-Ser-Ser), LIILL (Leu-Ile-Ile-Leu-Leu), CMMCC (Cys-Met-Met-Cys-Cys), DEEDD (Asp-Glu-Glu-Asp-Asp), RKKRR (Arg-Lys-Lys-Arg-Arg), TAMRA-STTSS, TAMRA-LIILL, TAMRA-CMMCC, TAMRA-DEEDD, and TAMRA-RKKRR. Pentapeptide alone, or pentapeptides with crosslinking agents such as polymeric carbodiimide (PCI) and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) were treated to chemically damaged hair. Hair diameter and break strength (N = 40/case) were measured to calculate tensile strength of hair for computing hair repair ratio, and fluorescence yields (N = 20/case) were collected for hair treated with TAMRA-peptides. The tensile strength of hair treated with pentapeptides alone, or pentapeptides with cross-linking agents is consistent with the fluorescence yield from the microscope images of the cross-sectioned hair in vision and in numerical values. Pentapeptides consisting of hydrophobic amino acids (LIILL), amino acids with sulfur (CMMCC), and basic amino acids (RKKRR) increased the tensile strength in perm-damaged hair. Pentapeptides with no extra carboxyl/amine groups in R group of amino acids resulted in no significant differences in hair strength and fluorescence yield among hairs treated with alone and with crosslinkers. Pentapeptides with extra carboxyl groups or amine groups enabled further strengthening of hair due to increased bonds within the hair after carbodiimide coupling reaction. The hair repairs of pentapeptides with various amino acid sequences were studied using crosslinking. Depending on the physical characteristics of comprising amino acids, the restoration of damaged hair was observed with tensile strength of hair and fluorescence signals upon cross-sectioned hair in parallel to possibly understand the binding tendency of each pentapeptide within the hair.

A Study on the low voltage secondary distribution method (2차 저압 배전방식 관한 연구)

  • Song, Il-Keun;Park, Gu-Perm;Kim, Young-Lae;Kwak, Hee-Ro;Kweon, Dong-Jin;Chong, Yong-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.32-34
    • /
    • 1993
  • In Korea, the low voltage secondary distribution method comprises lots of the maintainable and conservative problems. So, this paper deals with the plans to solve and decide the unification of the low voltage secondary. That is ; for the unification plan of the low voltage secondary must be previously solved the breaking of netural line in $3{\phi}4W$, $1{\phi}3W$ and enacted the flicker criteria in distribution power system. To decide the low voltage secondary should take into considersion by economics, security and future. The flicker fluctuation in the low voltage secondary 7.4% in responsibility limited place and under 10% in Arc welding. To prevent the netural line in $3{\phi}4W$, $1{\phi}3W$ must be thoroughly constructructed, joined the two sleeves.

  • PDF

A Study on Risk Communication and Risk Perception in Environmental Problems (환경문제의 위해도 인식과 위해도 홍보 프로그램의 효과분석 -라돈과 다이옥신을 중심으로-)

  • 김진용;신동천;박성은;임영욱;황만식
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.4
    • /
    • pp.315-324
    • /
    • 2002
  • Risk communication can be defined as the exchange of information about the nature, magnitude, significance, acceptability, and management of risk. The effect of risk communication on the perception and knowledge towards risk of environmental pollutants and it's related factors were investigated in this study. To investigate perception and knowledge of students and teachers towards risk of environmental pollutants, we conducted the survey using self-administrated questionnaire. The subjects were 574 for the first survey and 465 for the seconds survey from May to June, 2000. The main methods of transmission used in this study- through video tape, visual materials, question and answer, and participation in measuring pollutants - were not a one - way street. But an interactive process where information and opinions were exchanged among individuals, groups, and institutions. Environmental pollutants measured with participation of study subjects was Radon in the class room. The concentration of Radon was measured using E -PERM Device by installing it at each site for about 5 days. Subjects showed much interest in environmental pollution. Also, more than 98% of total subjects were perceived as Korea is seriously contaminated at present. By risk communication activity, risk perception of all subjects about Radon was increased, on the other hand, risk perception of Dioxin was decreased except for elementary student. Moreover, knowledge of all subjects about environmental risk was significantly increased (p =0.0001) and effort of reducing environmental pollution was more increased (p<0.05). There is need to further develop, refine, and integrate these approaches environmental risk communication study, there is an even more pressing need to accelerate the diffusion of environmental risk communication practice into government and organizations.

A Study on the Radon Concentration in the Office (사무실 내 라돈 농도에 관한 연구)

  • Choi, Hyun Woo;Kim, Chi-Nyon;Won, Jong-Uk;Kim, Hong-Kwan;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.334-341
    • /
    • 2016
  • Objectives: This study is aimed at examining radon exposure in offices and the factors that can influence the concentrations. Methods: Indoor radon concentrations in a total of 30 places were measured from January 18 to 21, 2016, targeting six buildings in Seoul with different completion years. The measurement was conducted according to the radon measurement guidelines for indoor air suggested by the Ministry of Environment. Results: As a result of comparing each average concentration, underground area concentration was $42.850{\pm}22.501Bq/m^3$, and that of the ground floors was $27.850{\pm}12.232Bq/m^3$, which was lower than the concentration in the underground areas and statistically significant (p=0.045). As a result of comparing the concentration according to whether or not outside air entered, the average concentration for ventilated areas was $24.876{\pm}11.833Bq/m^3$, and the average concentration for enclosed areas was $47.892{\pm}19.375Bq/m^3$. The concentration in ventilated areas was lower at a statistically significant level (p=0.001). Finally, as a result of the multiple regression analysis for evaluating the factors influencing radon concentration, only ventilation was significant (p=0.007). Conclusions: As a result of measuring radon in office buildings, there was no place that exceeding the recommended standard of the US EPA, but the concentration in poorly ventilated areas was measured to be high. An effort to manage radon concentration and reduce it through the improvement of ventilation systems, repeated measurement is necessary in the future.

A New Attempt to Establish the Extrinsic Aging Hair Model to Evaluate The Response to Aging in Physical Property (모발 노화에 따른 물성변화와 외인성 노화모델의 개발)

  • Song, Sang-Hun;Choi, Wonkyung;Park, Hyunsub;Lim, Byung Tack;Park, Kyoung Ran;Kim, Younghyun;Park, Sujin;Son, Seong Kil;Lee, Sang-Min;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.2
    • /
    • pp.185-198
    • /
    • 2019
  • Human tissue undergoes aging by the oxidant damage via structural change and its physical properties. The skin aging process is well known and many evaluations have been conducted. However, studies on hair aging were relatively few and thus care for aging hair is difficult. This study aims to fabricate an aging hair and identify anti-aging effect with known ingredient in anti-aging. First of all, physical properties of aging hair of age 60s by physiologically intrinsic factors were compared to those of the hair made by various extrinsic factors such as several chemical reactions and iteration numbers of the treatments. The extrinsic aging hair of this study relates to the less amount of lipid and to the hair of perm treated once accordingly, wherein several physical properties, preferably comprise roughness and tensile strength, present a novel concept of the intrinsic aging hair. The penetration of peptide into the aging hair was leading the extrinsic hair towards more structurally directed a younger hair. In addition to the structural change, the penetration of the peptide enhanced texture and tensile strength of the aging hair. These patterns have been also found in addition of propolis. For the first time, these qualitative studies exhibit that indeed our extrinsic aging hair well describes the anti-aging efficacy as a receptor for a cross-linker and the ingredients of human hair.

A Study for Perception of Hair Damage Using Friction Coefficient of Human Hair (모발의 마찰계수를 통한 모발 손상 인식 연구)

  • Lim, Byung Tack;Seo, Hong An;Song, Sang-Hun;Son, Seong Kil;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.46 no.3
    • /
    • pp.295-305
    • /
    • 2020
  • Treatment for beauty using oxidizing agents damages hair with inducing structural alteration in cuticle layer, degradation of protein, and loss of lipid. This study connects a frictional coefficient upon the damaged hair by an instrumental test to the texture test by human being, and considered a moisture as a factor of the damage. A friction coefficient has been measured upon the hair with successive treatment of dye, perm, and bleach. The friction coefficient from the hair dye-treated three times was defined with 0.60, where 58% of answerer indicated an initial damage point as the hairs of iteration of dye-treatment increased. Even bleach treated three times results in 0.84 of friction coefficient corresponding to 88% of answerer attributed the hair to an initially damaged hair. In order to figure out a lipid loss in hair for human being to respond damage, a friction coefficient of the hair was controlled by removing 18-methyleicosanoic acid (18-MEA). The initial damage has been recognized by 0.60 of the friction coefficient for the 68% of answerer. Since moisture is the largest portion of the components in hair, moisture analysis has been performed to study a relationship between texture of damage and the friction coefficient from an instrumental evaluation. As an iteration of dye increases, the hair became hydrophilic with smaller contact angle. It is found that a damaged hair by dyeing possessed more than 0.42% of moisture compared to a healthy hair. Finally, it is elucidated that an increase of moisture in hair induced higher adhesive force corresponding to the friction coefficient, and the friction coefficient above 0.6 is attributed to the preception of hair damage.