• Title/Summary/Keyword: ECT

Search Result 422, Processing Time 0.038 seconds

A Case of ECT-induced Arrhythmia(PVC) (전기경련요법에 의하여 유발된 심부정맥(PVC) 1례)

  • Kim, Duk-Ho;Lee, Ho-Taek;Paik, Ju-Hee;Lee, Sang-Yeon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.5 no.2
    • /
    • pp.214-217
    • /
    • 1997
  • Electroconvulsive therapy(ECT) is one of the most effective treatment modalities for the treatment of depression, mania, schizophrenia, or other neuropsychiatric disorders. But, reportedly ECT also can produce various forms of cardiac arrhythmia. We experienced a case of ECT-induced arrhythmia(PVC) accompanied with chest pain in a schizophrenic patient during the course of plain ECT. We conclude that there is a possible causal relationship between ECT and cardiac arrhythmia(PVC). The mechanisms of cardiac arrhythmia(PVC) due to ECT may be explained by the effects of ECT to vagal and sympathetic nervous systems. from this case report, We suggest that careful cardiac monitoring before, during, and after ECT with appropriate anesthetic preparation to a patient may enable to minimize the cardiovascular side effects of ECT in the patients with neuropsychiatric disorders.

  • PDF

Effects of Ensiled Cassava Tops on Rumen Environment Parameters, Thyroid Gland Hormones and Liver Enzymes of Cows Fed Urea-treated Fresh Rice Straw

  • Khang, Duong Nguyen;Wiktorsson, Hans
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.7
    • /
    • pp.936-941
    • /
    • 2004
  • Four rumen-cannulated cows (330 kg average weight at 4 years) were used to evaluate the supplement of ensiled cassava tops (ECT) (variety KM 94, 39% DM) on rumen functions, thyroid hormones and liver enzymes. The treatments, arranged in a 4 $\times$4 Latin square design, were ECT at 0, 50, 100 and 150 g CP 100 kg$^{-1}$ body weight (BW), and a basal diet of urea-treated fresh rice straw (UFRS) ad libitum and 1.1 kg dry matter (DM) cassava root meal (CRM) in each 30 day study period. The results showed a continuous decrease in dry matter intake (DMI) of UFRS with increasing level of ECT supplement (p<0.001). The highest total DMI was observed for treatment ECT$_{150}$ (2.68 kg DM 100 kg$^{-1}$ BW day$^{-1}$) followed by treatments ECT$_{100}$, ECT$_{50}$ and ECT$_{0}$, with 2.47, 2.24 and 2.06 kg DM 100 kg$^{-1}$ BW⋅day$^{-1}$, respectively. Increasing levels of ECT supplement increased the concentration of total volatile fatty acids (p<0.05) and ammonia nitrogen (p<0.05) and resulted in a decrease in pH (p<0.05). Overall average plasma triiodothyronine and thyroxine concentrations were 0.80, 0.82, 0.85 and 0.69 ng ml$^{-1}$ (p>0.05), and 50.9, 49.5, 50.7 and 42.4 ng ml-1 (p>0.05) for treatments ECT$_{0}$, ECT$_{50}$, ECT$_{100}$ and ECT$_{150}$, respectively. There were non-significant differences in alanine aminotransferase and aspartate aminotransferase among treatments. It is concluded that ECT is a valuable protein-rich feed supplement to cattle, and the highest level of on average 2.48 kg DM ECT per cow and day (28% of total DMI) did not significantly affect thyroid gland hormones and liver enzymes in cows.

Analysis of Quantitative Indices in Tl-201 Myocardial Perfusion SPECT: Comparison of 4DM, QPS, and ECT Program (Tl-201 심근 관류 SPECT에서 4DM, QPS, ECT 프로그램의 정량적 지표 비교 분석)

  • Lee, Dong-Hun;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.67-75
    • /
    • 2009
  • Purpose: As to the analytical method of data, the various programs in which it is used for the quantitative rating of the Tl-201 myocardial perfusion SPECT are reported that there is a difference. Therefore, the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made against data of the same patient. Using quantitative index that able to represent myocardial perfusion defect level, we aimed to determine correlation among three myocardial perfusion analysis programs 4DM (4DMSPECT), QPS (Quantitative Perfusion SPECT), ECT (Emory Cardiac Toolbox) that be used generally in most departments of Nuclear Medicine. Materials and Methods: We analyzed the 145 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Mediacal Center from December 1th 2008 to February 14th 2008. We sorted as normal group and abnormal group. Normal group consist of 80 patients (Male/Female=38/42, age:$65.1{\pm}9.9$) who have low possibility of cardiovascular disease. And abnormal group consist of 65 patients (Male/Female=45/20, age:$63.0{\pm}8.7$) who were diagnosed cardiovascular disease with reversible perfusion defect or fixed perfusion defect through myocardial perfusion SPECT results. Using the 4DM, QPS, and ECT programs, the total defect extent (TDE) such as LAD, LCX, RCA and the summed stress score (SSS) have been analysed for their correlations and statistical comparison with the paried t-test for the quantitative indices analysed from each group. Results: The correlation of 4DM:QPS, QPS:ECT, ECT:4DM each group result from 145 patients is 0.84, 0.86, 0.82 at SSS, 0.87, 0.84, 0.87 at TDE, and both index showed good correlation. In paired t-test and Bland-Altman analysis results showed no statistically significant difference in the comparison of QPS:ECT at the mean SSS and TDE, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index. The correlation of 4DM:QPS, QPS:ECT, ECT:4DM program results from abnormal group (65 patients) is 0.72, 0.72, 0.70 at SSS and 0.77, 0.70, 0.77 at TDE and TDE and SSS has a good correlation. In abnormal group, paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.89) and TDE (p=0.23) comparison, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). In normal group (80 patients), paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.95) and TDE (p=0.73) comparison. And 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). Conclusions: The perfusion defect of the Tl-201 myocardial perfusion SPECT was analyzed in not only the patient in whom it has the cardiovascular disease but also the patient in whom the possibility of the cardiovascular disease is few. In the comparison of the all group research, the mean of the TDE and SSS, 4DM was lower than QPS and ECT progrms. Each program showed good correlation and the results showed statistically significant difference. However, in this way, it is determined to be compatible about the analysis value in which the large-scale side between the programs uses each program a difference in a clinical in the Bland-Altman analyzed result in spite of the good correlation and cannot use. but, this analyzed result will be able to be usefully used as the reference material for the clinical read and is expected.

  • PDF

A Study on the Crack Depth Sizing Using ECT Technique for Martensitic Stainless Steel (ECT를 이용한 마르텐사이트 재질의 균열결함 깊이측정 연구)

  • Kim, Wang-Bae;Cheon, Keun-Young
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.2
    • /
    • pp.7-12
    • /
    • 2009
  • The flaws detected by the non-destructive surface test methods shall be sized by means of the volumetric test such as an UT(ultrasonic test) or an ECT(eddy current test) for the purpose of analyzing and repairing them. It is generally known that the ECT is a comparatively effective technique for the small size cracks which are located shallowly from the surface. On this study, the ECT technique was tried to size the depth of the crack-like EDM notches, and it is identified that the ECT is an appropriate depth sizing technique for the shallow cracks less than 3mm in the Martensitic CA6NM material.

  • PDF

Antiproliferative Effect and Apoptotic Mechanism of Extract of Corydalis Yanhusuo on Human Hepatocarcinoma Cells (현호색(玄胡索)이 인체간암세포 증식억제 및 apoptosis 유발에 미치는 영향)

  • Oh, Myun- Taek;Eom, Hyun-Sup;Chi, Gyoo-Yong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.6
    • /
    • pp.1437-1449
    • /
    • 2007
  • In this study, the effect of extract of Corydalis yanhusuo (ECT) used in Oriental medicine therapy was investigated on the cell growth and apoptosis of HepG2 human hepatoma cells. It was found that ECT could inhibit the cell growth effectively in a dose-dependent manner, which was associated with morphological change and apoptotic cell death such as formation of apoptotic bodies, DNA fragmentation and increased populations of apoptotic-sub G1 phase. And we observed the effects of ECT on loss of mitochondrial membrane potential (MMP), using the JC-1 probe by DNA flow cytometric analysis. Apoptosis of HepG2 cells by ECT was associated with a down-regulation of anti apoptotic Bcl-2 expression, inhibitor of apoptosis proteins (IAPs) expression and proteolytic activation of caspase-3 and caspase-9. However, ECT did not affect the pro-apoptotic Bax expression and activity of caspase-8. ECT treatment also concomitant degradation and /or inhibition of poly (ADP-ribose) polymerase (PARP), phospholipase C-1 ($PLC{\gamma}1$). Furthermore, ECT treatment caused a dose-dependent inhibition of iNOS and cyclooxygenase-2 (Cox-2). Additionally ECT have been implicated in the regulation of telomerase expression. ECT treatment induced the down-regulation of telomerase reverse transcriptase mRNA (hTERT) expression of HepG2 cells. Taken together, these findings suggest that ECT may be a potential chemotherapeutic agent for the control of HepG2 human hepatoma cells.

Development of New Low Frequency ECT Sensor to Detect Inner Defects(I) - Characteristic of Loss of Induced Electromotive Force - (내부결함 검출 가능한 저주파 ECT 센서개발(I) - 전자기 유도기전력 손실량의 특성-)

  • Park, Jeong-Ung;Jang, Mun-Seok;Gim, Guk-Ju;Kim, Beom-Ki
    • Journal of Welding and Joining
    • /
    • v.33 no.4
    • /
    • pp.57-62
    • /
    • 2015
  • Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing(ECT) is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. The New ECT sensor which can detect inner defects was developed regardless the condition of surface. This sensor is verified to do experiment which measure the loss of induced electromotive force. The loss of induced electromotive force was measured in 5.4% and this low frequency ECT device can detect internal defects at depth 20 mm.

Development of New Low Frequency ECT Sensor to Detect Inner Defects(II) - Application to Welding Specimens Included Defects - (내부결함 검출 가능한 저주파 ECT 센서개발(II) - 결함을 가진 소형 용접시험편에 적용 -)

  • Park, Jeong-Ung;Jang, Mun-Seok;Gim, Guk-Ju;Kim, Beom-Ki
    • Journal of Welding and Joining
    • /
    • v.33 no.4
    • /
    • pp.63-67
    • /
    • 2015
  • Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing(ECT) is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. The New ECT sensor which can detect inner defects was developed regardless the condition of surface. This sensor is verified to do experiment which measure the loss of induced electromotive force. The loss of induced electromotive force was measured in 5.4% and this low frequency ECT device can detect internal defects at depth 20 mm.

A Study on Distinguishing between Parent material and Weld ECT Signal at Seal Weld Zone for Steam Generator Tubing (증기발생기 전열관 밀봉용접부에서의 모재와 용접부 ECT 신호 구분에 관한 연구)

  • Cheon, Keun-Young;Shin, Ki-Seok;Nam, Min-Woo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.25-32
    • /
    • 2015
  • Many crack flaws have been detected at tubing seal weld zone in Steam Generator with Alloy600 material tubes. it is very difficult to discriminate the signal from parent material and that from weld zone because weld zone gives complicated ECT signal due to manufacturing processes. ECT signal analysis in the seal weld zone is very important since the tubes with crack in this area shall be out of service by plugging. The purpose of this paper is to distinguish between Parent material and Weld Zone ECT signal in the seal weld zone through the demonstration test of Steam Generator seal weld mock-up.

Review on the Working Hours of Radiation Work Plan for ECT through In-service Inspection (원전 가동중 ECT 검사 방사선 작업시간 고찰)

  • Chae, Gyung-Sun
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.57-63
    • /
    • 2004
  • As a part of In-service Inspection works in a nuclear power plant, Eddy Current Testing through all the outage of nuclear power plants has been controlled by the radiation management. From the case study about the periodical ECT work, the exposed dose rate of worker has announced over the organized dose rate before the radiation work, it affects the personnel exposed dose management and radiation work permit issue. It is not easy to get some information about ECT related working hours, scope of work and how many workers to forecast the radiation working and the predict dose exposure. It should be need the data accumulation about ECT related radiation work to prepare the ALARA achievement and the radiation work plan for dose mitigation. We can discuss a few information about ECT related radiation working issue for the application of predict dose exposure on this paper.

Characteristics Analysis of ECT/EVT within Epoxy Spacer (스페이서 내장형 ECT/EVT의 특성분석)

  • Park, Seong-Hee;Jeong, Hae-Eun;Lim, Kee-Joe;Kang, Seong-Hwa;Jeong, Jong-Hun;Kim, Pyung-Jung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.509-510
    • /
    • 2006
  • 전류 및 전압을 측정하는 것은 오래전부터 CT(current transformer)/PT(potential transformer) 가 많이 사용되어져 왔지만, 이들은 iron core를 사용하기 때문에 포화특성이 발생하게 되어, 오차를 유발하게 된다. 이에 대한 대처 방안으로서 현재는 로고스키코일 및 분압방식을 이용한 ECT/EVT에 대한 적용이 진행이 되고 있다. ECT/EVT는 포화특성이 없고, 선형성이 매우우수하며, 소형, 경량이라는 점에서 현재 배전반의 변화 추세를 구현할 수 있는 충분한 능력을 지니고 있다. 이에 본 논문에서는 ECT/EVT를 제작하여, 특성을 분석하고자 한다. 특이점은 ECT/EVT가 EPOXY SPACER에 내장이 되어 사용이 되며, 이런 사용조건하에서의 이들의 특성이 변화 될 수 있는지를 살펴보았다. 그 결과 EPXOY 몰딩하에서도 그 선형성을 잃지 않았으며, 원하는 오차인 ${\pm}1%$에 부합되는 결과를 나타내었다.

  • PDF