• Title/Summary/Keyword: EIT

Search Result 120, Processing Time 0.027 seconds

Analysis on Deduction of Energy-IT Convergence Technologies by the Analytic Hierarchy Process (AHP를 이용한 에너지-IT 융합기술 도출에 관한 연구)

  • Oh, Nam-Gul;Kim, Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.7B
    • /
    • pp.1091-1097
    • /
    • 2010
  • Energy and environment problem has been arisen and become one of the major concerns all over the world, due to scarce energy resources and inefficient energy consumption. Recently, energy-IT(EIT) convergence technology has been getting more attention, being expected to be one of key technologies to resolve the problem, and R&D projects on various areas of EIT convergence technologies have been launched in many countries on a large scale. Korea government and companies have also been interested in the development of EIT technologies, however, the scopes of technology areas are limited to just a small part such as smart grid technology. This paper investigates effectiveness of each EIT convergence technology and deduces EIT convergence technologies using AHP(Analytic Hierarchy Process). It is expected that our research could be meaningful information supporting policies on R&D projects of EIT convergence technologies promoted to save energy and strengthen the national competitiveness. Our research results show that the EIT convergence technology area of green building would be the most effective EIT convergence technology except smart grid, and network-based energy management system would be the most effective amongst the sub-areas of green building.

Gated Conductivity Imaging using KHU Mark2 EIT System with Nano-web Fabric Electrode Interface (나노웹 섬유형 전극 인터페이스와 KHU Mark2 EIT 시스템을 이용한 생체신호 동기 도전율 영상법)

  • Kim, Tae-Eui;Kim, Hyun-Ji;Wi, Hun;Oh, Tong-In;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.39-46
    • /
    • 2012
  • Electrical impedance tomography(EIT) can produce functional images with conductivity distributions associated with physiological events such as cardiac and respiratory cycles. EIT has been proposed as a clinical imaging tool for the detection of stroke and breast cancer, pulmonary function monitoring, cardiac imaging and other clinical applications. However EIT still suffers from technical challenges such as the electrode interface, hardware limitations, lack of animal or human trials, and interpretation of conductivity variations in reconstructed images. We improved the KHU Mark2 EIT system by introducing an EIT electrode interface consisting of nano-web fabric electrodes and by adding a synchronized biosignal measurement system for gated conductivity imaging. ECG and respiration signals are collected to analyze the relationship between the changes in conductivity images and cardiac activity or respiration. The biosignal measurement system provides a trigger to the EIT system to commence imaging and the EIT system produces an output trigger. This EIT acquisition time trigger signal will also allow us to operate the EIT system synchronously with other clinical devices. This type of biosignal gated conductivity imaging enables capture of fast cardiac events and may also improve images and the signal-to-noise ratio (SNR) by using signal averaging methods at the same point in cardiac or respiration cycles. As an example we monitored the beat by beat cardiac-related change of conductivity in the EIT images obtained at a common state over multiple respiration cycles. We showed that the gated conductivity imaging method reveals cardiac perfusion changes in the heart region of the EIT images on a canine animal model. These changes appear to have the expected timing relationship to the ECG and ventilator settings that were used to control respiration. As EIT is radiation free and displays high timing resolution its ability to reveal perfusion changes may be of use in intensive care units for continuous monitoring of cardiopulmonary function.

EIT Image Reconstruction Using SPSA (SPSA를 이용한 EIT 영상복원)

  • Kim, Ho-Chan;Boo, Chang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2721-2723
    • /
    • 2002
  • Electrical impedance tomograpy(EIT) determines the resistivity distribution inside an inhomogeneous target by means of voltage and current measurements conducted at the target boundary. In this paper, a simultaneous perturbation stochastic approximation(SPSA) approach is proposed for the solution of the EIT image reconstruction. Results of numerical experiments of EIT solved by the SPSA approach are presented and compared to that obtained by the modified Newton-Raphson(mNR) method.

  • PDF

SPSA Approach to Image Reconstruction in Electrical Impedance Tomograhpy (전기 임피던스 단층촬영법에서 SPSA를 이용한 영상복원)

  • 김호찬;부창진;이윤준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.23-28
    • /
    • 2004
  • In EIT, various image reconstruction algorithms have been used in order to compute the internal resistivity distribution of the unknown object with its electric potential data at the boundary. Mathematically the EIT image reconstruction algorithm is a nonlinear ill-posed inverse problem. In this paper, a SPSA approach is proposed for the solution of the EIT image reconstruction. Results of numerical experiments of EIT solved by the SPSA approach are presented and compared to that obtained by the modified Newton-Raphson(mNR) method.

Coupling Intensity Effects in Ladder-type Electromagnetically Induced Transparency of Rb atoms (결합광 세기에 따른 Rb 원자의 사다리형 전자기 유도 투과)

  • Moon, H.S.;Lee, L.;Kim, J.B.
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • We have studied the polarization effects and the coupling intensity effects of electromagnetically induced transparency(EIT) in the 5S$_{1}$2-/5P$_{3}$2-/5D$_{5}$2/ ladder system of Rb. We obtained the EIT spectrum with the hyperfine structure of 5D$_{5}$2/ transitions and the minimal width of the measured EIT spectrum was 6.5 MHz. We observed the change of the relative magnitudes of the hyperfine structure of EIT according to not only the polarizations of lasers but also the intensity of the coupling laser. The cause of the coupling intensity effects is that the EIT signal nonlinearly increases to the coupling intensity.

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

Validation of Electrical Impedance Tomography Qualitative and Quantitative Values and Comparison of the Numeric Pain Distress Score against Mammography

  • Juliana, Norsham;Shahar, Suzana;Chelliah, Kanaga Kumari;Ghazali, Ahmad Rohi;Osman, Fazilah;Sahar, Mohd Azmani
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5759-5765
    • /
    • 2014
  • Electrical impedance tomography (EIT) is a potential supplement for mammogram screening. This study aimed to evaluate and feasibility of EIT as opposed to mammography and to determine pain perception with both imaging methods. Women undergoing screening mammography at the Radiology Department of National University of Malaysia Medical Centre were randomly selected for EIT imaging. All women were requested to give a pain score after each imaging session. Two independent raters were chosen to define the image findings of EIT. A total of 164 women in the age range from 40 to 65-year-old participated and were divided into two groups; normal and abnormal. EIT sensitivity and specificity for rater 1 were 69.4% and 63.3, whereas for rater 2 they were 55.3% and 57.0% respectively. The reliability for each rater ranged between good to very good (p<0.05). Quantitative values of EIT showed there were significant differences in all values between groups (ANCOVA, p<0.05). Interestingly, EIT scored a median pain score of $1.51{\pm}0.75$ whereas mammography scored $4.15{\pm}0.87$ (Mann Whitney U test, p<0.05). From these quantitative values, EIT has the potential as a health discriminating index. Its ability to replace image findings from mammography needs further investigation.

A Model of a Simplified Mammography Geometry for Breast Cancer Imaging with EIT (전기임피던스 단층촬영법을 위한 단순화된 매모그래피 구조의 모델)

  • Choi, Myoung-Hwan
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.221-226
    • /
    • 2006
  • Electrical impedance tomography (EIT) is a technique for determining the electrical conductivity and permittivity distribution within the interior of a body from measurements made on its surface. One recent application area of the EIT is the detection of breast cancer by imaging the conductivity and permittivity distribution inside the breast. The present "gold standard" for breast cancer detection is X-ray mammography, and it is desirable that EIT and X-ray mammography use the same geometry. This paper presents a forward model of a simplified mammography geometry for EIT imaging. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and Validated by experiment using a phantom tank.

  • PDF

Fast EIT static image reconstruction using the recursive mesh grouping method (Mesh 그룹화 방법을 이용한 EIT 정적 영상 복원의 고속화)

  • 조경호;우응제;고성택
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.3
    • /
    • pp.63-73
    • /
    • 1997
  • For the practical applications of the EIT technology, it is essential to reconstruct sttic images iwth a higher spatial resolution in a reasonalble amount of processing time. Using the conventional EIT static image reconstruction algorithms, however, the processing time increases exponential with poor convergence characteristics as we try to get a higher spatial resolution. In order to overcome this problem, we developed a recursive mesh grouping method based on the Fuzzy-GA like algorithm. Computational simulation using the well-known improve dewton-raphson method with the proposed recursive mesh grouping algorithm shows a promising result that we can significantly reduce the processing time in the reconstruction of EIT static images of a higher spatial resolution.

  • PDF

Design 2-Dimensional Digital Filter In Reconstruction Of EIT

  • Kang, Dong-Hoon;Kang, Byung-Chae;Kim, Ji-Hoon;Hwang, Sang-Pil;Kim, Jin-Yeop;Jang, Jae-Duck;Lee, Seung-Ha;Choi, Bong-Yeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.36-39
    • /
    • 2004
  • Electrical impedance tomography (EIT) has been suffered from the severe ill-posedness which is caused by the inherent low sensitivity of boundary measurements to any changes of internal resistivity values. So, small noise occur unexpected reconstruction image. Generally in EIT system, if measured voltage includes noise, we can't find object location and resistivity values. In this paper, we propose digital filter for measured voltage in EIT. Newton-Raphson is the most..popular algorithm in EIT, but noise cause to blur image. We use Fourier transform (FT) in order to minimize the noise and design the filter. After filtering, result of reconstruction image is improved better than before filtering.

  • PDF