• Title/Summary/Keyword: EM Pulse

Search Result 29, Processing Time 0.037 seconds

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Accelerated Life Testing and Validity Evaluation of Finger Strips Used for Electromagnetic Shielding Doors (전자파 차폐 도어용 핑거 스트립의 가속수명시험 및 유효성 평가)

  • Lee, Joo Hong;Kim, Do Sik;Chang, Mu Seong;Cho, Hae Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.831-837
    • /
    • 2015
  • Many persons and electronic devices are exposed to electromagnetic (EM) waves generated from magnetic resonance imaging (MRI) equipment, EM pulses (EMPs), and many other kinds of EM wave devices. Finger strips are used to provide shielding from these EM waves. Because of the high thermal conductivity of finger strips, they are used in the design of specialized doors that are installed in shielded rooms. In this study, we perform an accelerated life test using the load acceleration stress, which affects the main failure mode of finger strips. We predict the life of the finger strip under normal usage conditions based on the results of the accelerated life test. We compare the results with those predicted from the life test under normal usage conditions to evaluate the validity of accelerated life testing.

Analysis Method for Full-length LiDAR Waveforms (라이다 파장 분석 방법론에 대한 연구)

  • Jung, Myung-Hee;Yun, Eui-Jung;Kim, Cheon-Shik
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.44 no.4 s.316
    • /
    • pp.28-35
    • /
    • 2007
  • Airbone laser altimeters have been utilized for 3D topographic mapping of the earth, moon, and planets with high resolution and accuracy, which is a rapidly growing remote sensing technique that measures the round-trip time emitted laser pulse to determine the topography. The traveling time from the laser scanner to the Earth's surface and back is directly related to the distance of the sensor to the ground. When there are several objects within the travel path of the laser pulse, the reflected laser pluses are distorted by surface variation within the footprint, generating multiple echoes because each target transforms the emitted pulse. The shapes of the received waveforms also contain important information about surface roughness, slope and reflectivity. Waveform processing algorithms parameterize and model the return signal resulting from the interaction of the transmitted laser pulse with the surface. Each of the multiple targets within the footprint can be identified. Assuming each response is gaussian, returns are modeled as a mixture gaussian distribution. Then, the parameters of the model are estimated by LMS Method or EM algorithm However, each response actually shows the skewness in the right side with the slowly decaying tail. For the application to require more accurate analysis, the tail information is to be quantified by an approach to decompose the tail. One method to handle with this problem is proposed in this study.

Derivation of Acoustic Target Strength Equation Considering Pulse Type of Acoustic Signal (펄스 타입의 음향신호를 고려한 음향표적강도 이론식 개발)

  • Kim, Ki-June;Hong, Suk-Yoon;Kwon, Hyun-Wung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.812-819
    • /
    • 2007
  • Acoustic Target Strength (TS) is a major parameter of the active sonar equation, which indicates the ratio of the radiated intensity from the source to the re-radiated intensity by a target. This research provides the time pattern of TS in time domain, which is applicable to pulse modulated acoustic pressure field. If the time pattern of TS is predicted by using TS equation in frequency domain, it takes long time and difficult since time function pulsed acoustic wave may be decomposed into their frequency domain components. But TS equation in time domain has a convenience. If the expression for pulsed acoustic field has been obtained, the problem can be solved. Furthermore this paper introduces about mathematical equivalence quantities between EM wave and Acoustic Wave.

  • PDF

Physiological Parameters Related to Health of The Elderly (노인의 건강관련 생리적 지수에 관한 연구)

  • Kim Jong Im;So Hee Young;Kim Hyun Li
    • Journal of Korean Public Health Nursing
    • /
    • v.14 no.2
    • /
    • pp.271-280
    • /
    • 2000
  • The purpose of this study was to identify the health status of elderly. Subjects were 132 older people who live in home and institution located Taejon metropolitan city. Data were collected from May 1997 to April 1998. To obtain data about health status of elderly. pulse, respiration, systolic and diastolic blood pressure. grip strength. pinch pressure. flexibility, arm circumference. triceps skin fold thickness were measured. Data were analyzed for frequency. percentage. t-test using SPSS pc+ program. The results were as follows: 1. $74.4\%$ of subjects was perceived as 'good' in their health status. 2. Mean pulse, mean respiration, systolic and diastolic blood pressure were with in normal limits. There were no statistical differences between men and women in pulse, respiration, systolic and diastolic pressure. 3. Left and right grip strength were 24.89 psi and 25.23psi. The grip strength in men was higher than that of women. It showed statistically difference between men and women in grip strength. 4. Left and right pinch pressure were 7 pound and 7.32 pound. There was statistically difference of pinch pressure between men and women. 5. left flexibility was better than right flexibility of subjects. There was no statistically significant difference between men and women in flexibility. 6. Arm circumference was 24.96cm and there was no statistically significant difference between men and women. 7. Mean skin fold thickness was 12.83 em. Skin fold thickness in men was lower than that of women. It showed statistically difference between men and women. From these results, further study should be considered gender differences in health status of elders and carried in larger sample than this study.

  • PDF

회전기 고정자권선의 부분방전 진단용 평면 패치센서의 설계 및 실험

  • Yang, Sang-Hyeon;Park, No-Jun;Kim, Chung-Sik;Park, Dae-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.228-228
    • /
    • 2009
  • In stator windings of a 6.6kV rotating machine, internal discharge, corona discharge, and surface discharge are mainly caused by internal voids and insulation degradation. In the case of the discharge spark and electromagnetic pulse generated from a discharge source, we can detect it using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, we designed and fabricated a planar patch sensor using a CST-MWS simulation, and PD signals from artificial defected stator windings were also measured by the sensor proposed in this study. Furthermore, In the results of the experiment, it showed similar performance to the HFCT sensor.

  • PDF

Dielectric Characteristics of $SF_6/N_2$ Mixture Insulation Gas for HV GIL (초고압 GIL을 위한 $SF_6/N_2$ 혼합가스의 절연특성)

  • Chang, Yong-Moo;Kim, Chul-Ho;Kim, Jeong-Tae;Koo, Ja-Yoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.49-49
    • /
    • 2010
  • In this paper, a full scaled gas discharge chamber was designed and fabricated for evaluating the dielectric performance of SF6/N2 mixture gases. And it describes work on AC and lightning impulse dielectric characteristics of SF6/N2 mixture insulation gas from experiments and full scale models.

  • PDF

Design of Multipactor-free S-band Duplexer Using New Test Method for Space Applications

  • Choi, Seung-Woon;Kim, Day-Young;Kwon, Ki-Ho;Won, Young-Jin;Lee, Yun-Ki
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.4
    • /
    • pp.217-221
    • /
    • 2006
  • Multipactor-free S-band duplexer based on inter-digital cavity type filter is proposed and demonstrated by in-house mulitpactor test facility for satellite RF components. Multipactor sensitivity of designed duplexer is analyzed by checking it out the maximum field accumulated region inside duplexer and calculating the electric field intensities at each resonator using 3D EM simulation in order to restrict the minimum gap distance as 2.5 mm which handles 43.13 dBm RF input power. Multipactor threshold was finally detected at 44 dBm in experiment for pulse mode test. The developed multipactor test method is cost effective, simple structure and gives a good agreement compared with the previous high cost MP test methodologies.

The Operating Characteristic Analysis of PM-type MAGNETIC CONTACTOR (영구자석형 전자접촉기의 동작특성 해석)

  • Cho, Hyun-Kil;Lee, Eun-Woong;Kim, Gil-Su;Kim, Il-Jung;Kim, Sung-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.792-794
    • /
    • 2000
  • This paper describes the design and the analysis of electromagnetic system of Magnetic Switch using 2D parametric finite element method(EM-Pulse). Magnetic Switch is electrical equipment, which is widely used for switching on/off motors in industrial field. The transient state is simulated in order to calculate the response time of Magnetic Switch. The simulation is based upon a step-by-step integration of the electric circuit equations and the core movement. The contactor uses a permanent magnet for maintaining the closed state. The presented solution takes account of non-linear magnetic material property and spring force controlled by core position. The dynamic response of Magnetic Switch predicted by the simulation agrees closely with the required condition.

  • PDF

Design Method for Negative Group Delay Circuits Based on Relations among Signal Attenuation, Group Delay, and Bandwidth

  • Na, Sehun;Jung, Youn-Kwon;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • v.19 no.1
    • /
    • pp.56-63
    • /
    • 2019
  • Typical negative group delay circuits (NGDC) are analyzed in terms of signal attenuation, group delay, and bandwidth using S-parameters. By inverting these formulations, we derive and present the design equations (for NGD circuit elements) for a desired specification of the two among the three parameters. The proposed design method is validated through simulation examples for narrow- and wide-band pulse inputs in the time and frequency domains. Moreover, an NGDC composed of lumped elements is fabricated at 1 GHz for measurement. As a function of frequency, the circuit-/EM-simulated and measured group delays are in good agreement. The provided simple NGDC design equations may be useful for many applications that require compensations of some signal delays.