• 제목/요약/키워드: EM Pulse

검색결과 29건 처리시간 0.035초

이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발 (Development of Measurement System for Industrial Transportable Gamma Ray CT)

  • 김종범;정성희;문진호
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

전자파 차폐 도어용 핑거 스트립의 가속수명시험 및 유효성 평가 (Accelerated Life Testing and Validity Evaluation of Finger Strips Used for Electromagnetic Shielding Doors)

  • 이주홍;김도식;장무성;조해용
    • 대한기계학회논문집A
    • /
    • 제39권9호
    • /
    • pp.831-837
    • /
    • 2015
  • 사람과 전자기기들은 우리 주변의 환경 속, 특히 병원의 자기 공명 영상(Magnetic resonance imaging, MRI) 장비 또는 군용으로 사용되는 전자기 펄스(Electromagnetic pulse, EMP) 장비, 그리고 수많은 전자파를 만들어 내는 장치들에 노출되는 경우가 잦아졌다. 이러한 전자파는 사람과 전자기기에 유해하고, 이를 차폐하기 위해 사용되는 것 중에 하나가 핑거 스트립이다. 핑거 스트립은 열전도성이 좋기 때문에 전자파를 흡수하여 열로 변환한다. 이 특징을 효과적으로 이용하여 전자파 차폐가 필요한 실내의 특수 문짝에 핑거 스트립을 설치해서, 전자파로부터 사람과 전자기기들을 보호한다. 본 연구에서는 핑거 스트립의 주 고장모드에 영향을 주는 가속인자로 하중을 선택하여 가속수명시험을 실시한다. 가속수명시험의 결과로부터 핑거 스트립의 실사용조건 수명을 예측하며, 동일한 조건에서 실시한 수명 시험 결과와 비교하여 가속수명시험의 유효성을 평가하고자 하였다.

라이다 파장 분석 방법론에 대한 연구 (Analysis Method for Full-length LiDAR Waveforms)

  • 정명희;윤의중;김천식
    • 전자공학회논문지CI
    • /
    • 제44권4호통권316호
    • /
    • pp.28-35
    • /
    • 2007
  • 최근 중요한 매핑기술이 된 LiDAR(Light Detection And Ranging)는 다른 수치표고자료 획득 기법에 비해 높은 정확도와 세밀한 밀도를 가지고 있어 3차원 모델링에 필요한 높이정보를 제공한다. 이러한 시스템의 가장 중요한 작업은 디지털화된 리턴 펄스의 모양을 이해하여 수신권내의 반사되어 오는 시간을 측정하여 이와 대응되는 표면 위치를 계산하고 이를 지리좌표와 연결시키는 것이다. 디지털화된 파형(waveform)은 수신권내의 지표 형태에 따라 다른데 처음 발생된 펄스와 같은 단일 모드이거나 수신권내에 여러 표면이 있는 경우 각 반사 표면에 해당하는 여러 모드로 구성된 복잡한 파형일 수 있다. 자료처리 과정에서 반사표면에 대해 일관성 있는 거리측정 지점을 찾기 위해서는 리턴 파장에서 각 모드의 중심위치나 피크 진폭의 위치를 찾아내는 방법이 필요하다. 복잡한 파장의 경우에는 여러 개의 반사지점에 대해 정확한 높이를 계산해 내는 것이 쉽지 않은데 이를 위해 각 모드가 수신권내의 반사 표면에서 레이저 에너지가 반사되는 분포를 나타낸다고 가정하고 리턴 파장을 각 구성 모드로 분해하는 방법이 제안되었다. 이때 분석을 단순화하기 위해 레이저 출력 펄스 모양이 가우시안 분포를 따른다고 가정하고 전체 리턴 파장을 다변량 가우시안(multivariate Gaussian) 분포를 이용하여 분석한다. 여기서는 혼합분포에서 정확한 피크 위치와 half-width와 같이 모형의 파라미터에 대한 추정치를 구하기 위해 EM 알고리즘을 적용하여 MLE 값을 구하였다. 그러나 실제 레이저 고도계에서 얻어진 데이터는 가우시안이 아닌 오른쪽으로 기울어진 분포를 보여주고 있어 응용분야에 따라 정확한 분석이 필요한 경우 이러한 펄스 모양을 고려한 방법이 필요하다. 본 연구에서는 이러한 펄스 모양을 처리하기 위한 새로운 방법론이 제시되어 있다.

펄스 타입의 음향신호를 고려한 음향표적강도 이론식 개발 (Derivation of Acoustic Target Strength Equation Considering Pulse Type of Acoustic Signal)

  • 김기준;홍석윤;권현웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.812-819
    • /
    • 2007
  • Acoustic Target Strength (TS) is a major parameter of the active sonar equation, which indicates the ratio of the radiated intensity from the source to the re-radiated intensity by a target. This research provides the time pattern of TS in time domain, which is applicable to pulse modulated acoustic pressure field. If the time pattern of TS is predicted by using TS equation in frequency domain, it takes long time and difficult since time function pulsed acoustic wave may be decomposed into their frequency domain components. But TS equation in time domain has a convenience. If the expression for pulsed acoustic field has been obtained, the problem can be solved. Furthermore this paper introduces about mathematical equivalence quantities between EM wave and Acoustic Wave.

  • PDF

노인의 건강관련 생리적 지수에 관한 연구 (Physiological Parameters Related to Health of The Elderly)

  • 김종임;소희영;김현리
    • 한국보건간호학회지
    • /
    • 제14권2호
    • /
    • pp.271-280
    • /
    • 2000
  • The purpose of this study was to identify the health status of elderly. Subjects were 132 older people who live in home and institution located Taejon metropolitan city. Data were collected from May 1997 to April 1998. To obtain data about health status of elderly. pulse, respiration, systolic and diastolic blood pressure. grip strength. pinch pressure. flexibility, arm circumference. triceps skin fold thickness were measured. Data were analyzed for frequency. percentage. t-test using SPSS pc+ program. The results were as follows: 1. $74.4\%$ of subjects was perceived as 'good' in their health status. 2. Mean pulse, mean respiration, systolic and diastolic blood pressure were with in normal limits. There were no statistical differences between men and women in pulse, respiration, systolic and diastolic pressure. 3. Left and right grip strength were 24.89 psi and 25.23psi. The grip strength in men was higher than that of women. It showed statistically difference between men and women in grip strength. 4. Left and right pinch pressure were 7 pound and 7.32 pound. There was statistically difference of pinch pressure between men and women. 5. left flexibility was better than right flexibility of subjects. There was no statistically significant difference between men and women in flexibility. 6. Arm circumference was 24.96cm and there was no statistically significant difference between men and women. 7. Mean skin fold thickness was 12.83 em. Skin fold thickness in men was lower than that of women. It showed statistically difference between men and women. From these results, further study should be considered gender differences in health status of elders and carried in larger sample than this study.

  • PDF

회전기 고정자권선의 부분방전 진단용 평면 패치센서의 설계 및 실험

  • 양상현;박노준;김충식;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.228-228
    • /
    • 2009
  • In stator windings of a 6.6kV rotating machine, internal discharge, corona discharge, and surface discharge are mainly caused by internal voids and insulation degradation. In the case of the discharge spark and electromagnetic pulse generated from a discharge source, we can detect it using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, we designed and fabricated a planar patch sensor using a CST-MWS simulation, and PD signals from artificial defected stator windings were also measured by the sensor proposed in this study. Furthermore, In the results of the experiment, it showed similar performance to the HFCT sensor.

  • PDF

초고압 GIL을 위한 $SF_6/N_2$ 혼합가스의 절연특성 (Dielectric Characteristics of $SF_6/N_2$ Mixture Insulation Gas for HV GIL)

  • 장용무;김철호;김정태;구자윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.49-49
    • /
    • 2010
  • In this paper, a full scaled gas discharge chamber was designed and fabricated for evaluating the dielectric performance of SF6/N2 mixture gases. And it describes work on AC and lightning impulse dielectric characteristics of SF6/N2 mixture insulation gas from experiments and full scale models.

  • PDF

Design of Multipactor-free S-band Duplexer Using New Test Method for Space Applications

  • Choi, Seung-Woon;Kim, Day-Young;Kwon, Ki-Ho;Won, Young-Jin;Lee, Yun-Ki
    • Journal of electromagnetic engineering and science
    • /
    • 제6권4호
    • /
    • pp.217-221
    • /
    • 2006
  • Multipactor-free S-band duplexer based on inter-digital cavity type filter is proposed and demonstrated by in-house mulitpactor test facility for satellite RF components. Multipactor sensitivity of designed duplexer is analyzed by checking it out the maximum field accumulated region inside duplexer and calculating the electric field intensities at each resonator using 3D EM simulation in order to restrict the minimum gap distance as 2.5 mm which handles 43.13 dBm RF input power. Multipactor threshold was finally detected at 44 dBm in experiment for pulse mode test. The developed multipactor test method is cost effective, simple structure and gives a good agreement compared with the previous high cost MP test methodologies.

영구자석형 전자접촉기의 동작특성 해석 (The Operating Characteristic Analysis of PM-type MAGNETIC CONTACTOR)

  • 조현길;이은웅;김길수;김일중;김성종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.792-794
    • /
    • 2000
  • This paper describes the design and the analysis of electromagnetic system of Magnetic Switch using 2D parametric finite element method(EM-Pulse). Magnetic Switch is electrical equipment, which is widely used for switching on/off motors in industrial field. The transient state is simulated in order to calculate the response time of Magnetic Switch. The simulation is based upon a step-by-step integration of the electric circuit equations and the core movement. The contactor uses a permanent magnet for maintaining the closed state. The presented solution takes account of non-linear magnetic material property and spring force controlled by core position. The dynamic response of Magnetic Switch predicted by the simulation agrees closely with the required condition.

  • PDF

Design Method for Negative Group Delay Circuits Based on Relations among Signal Attenuation, Group Delay, and Bandwidth

  • Na, Sehun;Jung, Youn-Kwon;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • 제19권1호
    • /
    • pp.56-63
    • /
    • 2019
  • Typical negative group delay circuits (NGDC) are analyzed in terms of signal attenuation, group delay, and bandwidth using S-parameters. By inverting these formulations, we derive and present the design equations (for NGD circuit elements) for a desired specification of the two among the three parameters. The proposed design method is validated through simulation examples for narrow- and wide-band pulse inputs in the time and frequency domains. Moreover, an NGDC composed of lumped elements is fabricated at 1 GHz for measurement. As a function of frequency, the circuit-/EM-simulated and measured group delays are in good agreement. The provided simple NGDC design equations may be useful for many applications that require compensations of some signal delays.