Inspection on the acoustic output of the focused extracorporeal focused shock wave therapeutic devices approved by MFDS (식약처에서 허가된 집속형 ESWT 치료기의 음향 출력 분석)

  • Choi, Min Joo;Jeon, Sung Joung;Kwon, Oh Bin;Lee, Min Young;Cho, Jin Sik;Kim, Han Soo;Maeng, Eun Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.4
    • /
    • pp.303-317
    • /
    • 2020
  • Extracorporeal Shock Wave Therapy (ESWT) is an innovative treatment in chronic musculoskeletal pain management and cardiovascular diseases. In this study, we surveyed the acoustic shock wave outputs from the domestically used focal type ESWT devices. The survey data were collected through 30 technical documents registered to the Ministry of Food and Drug Safety (MFDS), Rep. Korea. The results show that the focusing geometry varies largely, 5 mm to 65 mm in the focal length, 3 mm to 30 mm in focal width, and 4 mm to 108 mm in focal depth. The maximum positive pressure (P+) ranges from 7 MPa to 280 MPa, the focal Energy Flux Density (EFD) from 0.0035 mJ/㎟ to 35 mJ/㎟, and the energy per pulse (E) from 0.737 mJ to 80.86 mJ. All domestic PE-type (five) and one EM-type domestic devices included in the analysis of the correlation between P+ and EFD are shown to be far beyond the usual ranges and do not comply with expected correlation so that the reliability of their data was suspected. For the suspected, post-performance tests are required by a recognized testing agency. MFDS guidelines need to be revised so that the pass criteria for the shock wave acoustic outputs can be based on the clinical tests for indications.

Analysis of PCI Cable Effects in HEMP Conducted Disturbance (HEMP 전도성 방해 펄스 전류 주입(PCI) 케이블의 영향 분석)

  • Jang, Tae-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.772-780
    • /
    • 2013
  • The high-altitude electromagnetic pulse(HEMP) conducted environment and the HEMP radiated environment are established as the consequences of a high-altitude nuclear explosion. The IEC 61000-2-10, the international standard, defines the HEMP conducted environment. The IEC 61000-5-5 defines how protective devices for conducted disturbance proposed for HEMP protection shall be specified. The IEC 61000-4-24 deals with methods for testing protective devices for HEMP conducted disturbance. The IEC 61000-4-24:1997 mainly describes the measurement method of small protective components. However, it does not provide the measurement method for a combination filter of a protective component and a filter which is widely used in recent. It is important to consider the characteristic of the measurement setup parameters like thickness and length of the cable and its height above ground plane etc. in establishing measurement setup because HEMP conducted disturbances include the frequency spectrum below 50 MHz. This paper deals with the optimized measurement method, considering the frequency spectrum of HEMP conducted disturbance, current waveform, and analyzing the effects of cables existing in the measurement setup.

The Design of a Planar Patch Sensor for Partial Discharge Diagnosis in 6.6 kV Rotating Machine Stator Windings (6.6 kV 회전기 고정자 권선에서 부분방전 신호 검출을 위한 평면 패치 센서 설계)

  • Lim, Kwang-Jin;Park, Noh-Joon;Kim, Hee-Dong;Ju, Young-Ho;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.5
    • /
    • pp.481-485
    • /
    • 2008
  • In stator windings of 6.6 kV rotating machine, corona discharge, surface discharge and internal discharge are caused mainly by internal voids and insulation degradation. Also, if partial discharge occurs in inner-part of stator windings, it will be happened electromagnetic pulses at wide frequency range. In case of discharge spark, electromagnetic pulse generated from discharge source, and we can detect it by using various RF resonators as an EM sensor. In order to detect these kind of electromagnetic sources, we have designed and fabricated planar patch sensor using CST MWS simulation, and also PD signals from artificial defected cable were measured by our proposed sensor. Furthermore, HFCT was used as a reference sensor and compared with our proposed new planar patch sensor.

Design of X-band 40 W Pulse-Driven GaN HEMT Power Amplifier Using Load-Pull Measurement with Pre-matched Fixture (사전-정합 로드-풀 측정을 통한 X-대역 40 W급 펄스 구동 GaN HEMT 전력증폭기 설계)

  • Jeong, Hae-Chang;Oh, Hyun-Seok;Yeom, Kyung-Whan;Jin, Hyeong-Seok;Park, Jong-Sul;Jang, Ho-Ki;Kim, Bo-Kyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.11
    • /
    • pp.1034-1046
    • /
    • 2011
  • In this paper, a design and fabrication of 40 W power amplifier for the X-band using load-pull measurement of GaN HEMT chip are presented. The adopted active device for power amplifier is GaN HEMT chip of TriQuint company, which is recently released. Pre-matched fixtures are designed in test jig, because the impedance range of load-pull tuner is limited at measuring frequency. Essentially required 2-port S-parameters of the fixtures for extraction optimal input and output impedances is obtained by the presented newly method. The method is verified in comparison of the extracted optimal impedances with data sheet. The impedance matching circuit for power amplifier is designed based on EM co-simulation using the optimal impedances. The fabricated power amplifier with 15${\times}$17.8 $mm^2$ shows the efficiency above 35 %, the power gain of 8.7~8.3 dB and the output power of 46.7~46.3 dBm at 9~9.5 GHz with pulsed-driving width of 10 usec and duty of 10 %.

Development of the HEMP Generation, Propagation Analysis, and Optimal Shelter Design Tool (고 고도 전자기파(HEMP) 발생과 전파해석 및 방호실 최적 설계 Tool 개발)

  • Kim, Dong Il;Min, Gyeong Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2331-2338
    • /
    • 2014
  • The HEMP threat may have acquired new, and urgent, relevance as the proliferation of nuclear weapons and missile technology accelerates of the North Korea, for example, is assessed as already having developed few atomic weapons, and is on the verge of North Korea already has missiles capable of delivering a nuclear warhead against South Korea. ITU K.78, K81 and IEC recommended its counter-measuring for the industrial facilities with navigation and sailing facilities in order to obviate the all of processor equipped system malfunctions from the EMP/HEMP but its simulation must only be done by the computer simulation which had studied on the 1960-1990 years USA/AFWL papers. This result has a significant activities to the South Korea being under the North Korea threat because all of HEMP related products was strongly limited for export. The HEMP cord which was developed newly by the KTI including the HEMP generation & propagation analysis, optimal shelter design tool, essential EM energy attenuation in multi-layered various soils and rocks and HEMP filter design tool. Especially, the least square fitting method was adopted to analysis for the EM energy attenuation in the soils and rocks because it has a various characteristics based on the many times field test reports.

Reference values for pulp oxygen saturation as a diagnostic tool in endodontics: a systematic review and meta-analysis

  • Paula Lambert;Sergio Augusto Quevedo Miguens Jr;Caroline Solda;Juliana Tomaz Sganzerla;Leandro Azambuja Reichert;Carlos Estrela;Fernando Branco Barletta
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.48.1-48.11
    • /
    • 2020
  • Objectives: This systematic review aimed to identify mean oxygen saturation values (SpO2) using pulse oximetry in permanent maxillary anterior teeth. Materials and Methods: The MEDLINE, Scientific Electronic Library Online, Cochrane Central Register of Controlled Trials, EMBASE, and Literatura Latino Americana em Ciências da Saúde electronic databases were searched. Combinations and variations of "oximetry" AND "dental pulp test" were used as search terms. Studies reporting means and standard deviations of SpO2 values were included. Two reviewers independently extracted data following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist. Heterogeneity was assessed using the I2 statistic, and all analyses were performed using R software. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool and the Newcastle-Ottawa scale. Results: Of the 251 studies identified, 19 met the eligibility criteria and were included (total sample, 4,541 teeth). In the meta-analysis, the mean SpO2 values were 84.94% (95% confidence interval [CI], 84.85%-85.04%) for the central incisors, 89.29% (95% CI, 89.22%-89.35%) for the lateral incisors, and 89.20% (95% CI, 89.05%-89.34%) for the canines. The studies were predominantly low-quality due to the high risk of bias associated with the index test, unclear risk regarding patient selection, and concerns about outcome assessment. Conclusions: Although most studies were low-quality, the oxygen saturation levels in normal pulp could be established (minimum saturation, 77.52%). Despite the risk of bias of the included studies, the reference values reported herein are clinically relevant for assessments of changes in pulp status.

The Analgesic Effect and Its Neuropathologic Changes of Pulsed Radiofrequency Lesions in the Sciatic Nerve of the Rat (백서 좌골신경에 시행한 박동성 고주파술 (Pulsed Radiofrequency)이 급성 통증과 신경조직에 미치는 영향)

  • Lee, Kee-Heon;Shin, Keun-Man;Kweon, Kyoung-Seok;Jung, Bae-Hee;Lim, So-Young;Hong, Soon-Yong;Choi, Young-Hee;Park, Young-Euy
    • The Korean Journal of Pain
    • /
    • v.13 no.2
    • /
    • pp.149-155
    • /
    • 2000
  • Background: Pulsed radiofrequency (RF) lesioning is a painless procedure and causes no neurodestruction and neuritis-like reaction are common following conventional RF lesioning. There is little data about the effect of pulsed RF especially with regard to its suitability for the treatment of acute pain. The possibility of a placebo effect cannot be ruled out because a double-blind study was not performed in previous studies. There is also no neuropathologic study about pulsed RF. Methods: The rats were anesthetized with sodium pentobarbital (40 mg/kg, i.p.; supplemented as necessary). The common sciatic nerve was exposed by blunt dissection through biceps femoris. Pulsed RF was administered to the common sciatic nerve using a 30 ms/s pulse with for 120 seconds. The temperature reached was no more than $42^{\circ}C$. Analgesia was determined using hot-plate assay shortly and, 3 days and 1 week before, and 2 weeks after operation. Lesions were examined with LM (light microscope) and EM (electron microscope) 2 weeks later. Results: There were no differences in response latencies between the control and experimental group. There were many vacuoles with hyaline bodies in the Schwann cell cytoplasm rather than axon in LM and larger electron dense bodies. No changes were found in the axon or unmyelinated fibers. Only small changes were found in the sheaths of myelinated fibers and Schwann cells. Conclusions: We therefore do think that any analgesic effect of pulsed RF is not a result of block of neural conduction. But rather than it can be attributed to others factors. It was also ineffective as a treatment for acute pain such as that caused by the hot-plate test.

  • PDF

The Effect of Electric Acupuncture Therapy on Myofascial Pain Syndrome (근근막 동통증후군과 전침(Electric Acupuncture)치료의 유효성에 관한 연구)

  • Jung, Mun-Boung;Lee, Sang-Han;Min, Boung-Ki;Yoon, Mi-Yean
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.1
    • /
    • pp.897-903
    • /
    • 1999
  • Many out patients of the rehabilitation center complaint a pain caused by suffering of MPS, and it brings many different kind of social and ecinomical problems such as medical expenses and the reduction in work efficiency. Therefore, we conducted a research to present a fast and effective treatment to the MPS patients. this research was conducted from November, 1996 to January 1998 with eighteen outpatients who agreed to be the subjects to our reserach. We applied the electric acupuncture on 28 different trigger point on the patients with mostly muscular-skeletal pain and some tender and radiating pain. After the treatment, VRS, VAS, PRI were used to measure the degree of the pain on the patients third and seventh visits, and following results were found. 1. To apply EAP treatment, we acupunctured 6em-Iong needles on Tps region, then the electrodes of pulse generater pg-306 E.S.T were connected on the top of the needles. the electric acupuncture therapy was conducted for 20 minutes with the intensity of 4hz - 60hz(auto wave). The treated electric intensity was the level at which the patients did not feel discomfort. 2. Thirteen out of the 18 participated patients were in their 30s and 40s(72.2%), showing highest frequency. There were more female than male with the ratio of 1 to 1:2. 3. six out of the participated patients (33.3%) had the pain for less then a week, and the average duration of the pain of the participated patients wear 0.8 years. 4. The pain occured mostly in the upper trapezius by 6 part (21.4%), then in the gluteus medius region by 4 part (14.3%). Many of the patients with the pain in the upper back area accompanied varios kind of the referred pains such as radiculopathy, HIVD and Frozen shoulder. 5. MPS occured more frequently on the right side than left side then left side and it seemed to be due to the frequent use of the right hand. 6. There was almost no difference in the measurement of the intensity of the pain right before and after the EAP treatment. Howerver, there was significant decrease in the numerical values of the VAS, and a little bit of decrease in the numerical values of the PRI after the EAP treatment. 7. Based on the results of this present research, it can be concluded that EAP can be used for the treating the myofascial pain syndrome with promptness and safety in most cases.

  • PDF

The Study of in Vivo Visual Pathway Tracing using Magnetic Magnanese Tracer (자성 망간 추적자를 이용한 in Vivo 시신경경로 추적에 관한 연구)

  • Bae, Sung-Jin;Chang, Yong-Min
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.42-47
    • /
    • 2007
  • Purpose: To evaluate the tracing of optic nerve tract using manganese enhanced magnetic resonance Imaging. Materials and Methods: After injecting $30{\mu}l$ of $MnCl_2(1mol)$ (1 mol) Into the retina of female New Zealand white rabbit, the contrast enhancements at major anatomical structures of optic nerve tract were evaluated by high resolution T1-weighted Images 12 hours, 24 hours, and 48 hours after $MnCl_2(1mol)$ Injection using 3D FSPGR (Fast Speiled Gradient Recalled echo) pulse sequence at 1.5T clinical MR scanner with high performance gradient system. Also, for quantitative evaluation, the signal-to-noise ratios of circular ROI on anatomical locations were measured. Results: The major structures on the optic nerve tract were enhanced after injecting $MnCl_2(1mol)$. The structures, which showed enhancement, were right optic nerve, optic chiasm, left optic tract, left lateral geniculate nucleus, left superior colliculus. The structures on the contralateral optic pathway to the right retina were enhanced whereas the structures on the ipsilateral pathway did not show enhancement. Conclusion: The Mn transport through axonal pathway of optic nerve sys)em was non- invasively observed after injecting injecting $MnCl_2$ at the retina, which is the end terminal of optic nerve system. This Mn transport seems to occur by voltage gated calcium $(Ca^{2+})$ channel and In case of direct Injection Into the retina, the fast transpori pathway of voltage gated calcium channel seems to be responsible for Mn transport.

  • PDF