• Title/Summary/Keyword: ERETIC

Search Result 2, Processing Time 0.018 seconds

Survey of ERETIC2 NMR for quantification

  • Hong, Ran Seon;Hwang, Kyung Hwa;Kim, Suncheun;Cho, Hwang Eui;Lee, Hun Joo;Hong, Jin Tae;Moon, Dong Cheul
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.17 no.2
    • /
    • pp.98-104
    • /
    • 2013
  • The ERETIC (Electronic REference To access In vivo Concentrations)2 method is a new qNMR experimental technique to measure analytes based on the signal of the reference compound without additional hardware equipment. In this study, ERETIC2 method was validated, and we sought to identify whether it would be possible to apply this method to a specific compound analysis of metabolites in plant. The $90^{\circ}$ pulse value (P1) and spin-lattice relaxation time ($T_1$) of each compound were measured for ERETIC2. The $9^1H$ of 3-(trimethylsilyl) propionic-2,2,3,3-$d_4$ acid (TSP) was used as a reference peak for ERETIC 2, and then, a suitable solvent and pulse sequence for each compound were selected. Under the NOESY-presat sequence, the relative accuracy error for quantitative analyses of primary metabolites was within the range of 5%, with the exception of glucose, which showed ${\geq}$ 55% error due to saturation. It showed excellent results for the quantification of glucose by using a $30^{\circ}$ pulse sequence, which did not suppress the water peak. In addition, the quantitative accuracy for secondary metabolites was extremely accurate, with an error ${\leq}$5% when considering the purity of the standard sample. The ERETIC2 method showed outstanding linearity, precision, and accuracy.

Comparative analysis of glycerin in cosmetics by LC/MS and 1H NMR (LC/MS와 1H NMR을 이용한 화장품속의 글리세린 비교분석)

  • Park, Gyo-Beom;Park, Chan Jo;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.400-405
    • /
    • 2007
  • The comparative analysis of glycerin in cosmetic samples was carried out by LC/MS and $^1H$ NMR spectrometry. For the LC/MS analysis, aqueous solution was controlled in strong basic condition with sodium hydroxide, and benzoyl chloride was added to the solution for the derivatization of glycerin. The derivative was extracted using pentane and analyzed by the LC/MS. For the $^1H$ NMR analysis, sample was directly dissolved in $D_2O$ solvent without pretreatment. The quantitative analysis of glycerin was done by $^1H$ NMR ERETIC method. The analysis results of LC/MS and $^1H$ NMR showed that the calibration curves were a good linearity with $r^2=0.9991$ in the range of 0.1 to $10{\mu}g/mL$ and $r^2=1$ in the range of 25 to $500{\mu}g/mL$, respectively.