• 제목/요약/키워드: ETS

검색결과 334건 처리시간 0.03초

도시지역 사무실내 공기 중 환경담배연기의 측정 - 흡연이 부유먼지 농도에 미치는 영향을 중심으로 - (Measurement of Environmental Tobacco Smoke in the Air of Offices in Urban Areas - Focusing on the Impact of Smoking on the Concentrations of Suspended Particles -)

  • 백성옥;박상곤
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.715-727
    • /
    • 2004
  • This study was carried out to evaluate non-smoker's exposure levels to environmental tobacco smoke (ETS) in the air of offices in urban areas. A total of 65 offices were selected from two large cities, i.e. Daegu and Daejeon. The field sampling was conducted repeatedly in summer (1999) and winter (1999~2000). The measured ETS markers included respirable suspended particles (RSP as PM$_{40}$ ), vapor and particulate phase ETS markers, including nicotine, 3-ethnyl pyridine (3-EP), ultraviolet absorbing particulate matter (UVPM), fluorescing particulate matter (FPM), and solanseol in ETS particles (SolPM). RSP was measured gravimetrically by a microbalance. The particle samples were then used for the determination of particulate ETS markers by HPLC, while vapor phase markers determined by GC/NPD. The analytical methods were validated for repeatability, linearity, detection limits, and duplication precision. The concentrations of RSP and other ETS markers were significantly higher in smoking offices than non-smoking offices. Despite the similar smoking strength in each office for different seasons, the concentration levels of ETS components appeared to be higher in winter than summer. The contributions of ETS to RSP concentrations based on SolPM, FPM, and UVPM methods were estimated to be in the range of 15.2 ~ 25.3% in smoking offices, whereas 2.4 ~ 15.9% in non-smoking offices. The cooling and heating types did not affect significantly the concentrations of RSP and other ETS markers. Finally, further research issues were suggested to obtain more scientific information on the non-smoker's exposure to ETS with respect to the frame of risk assessment..

밀폐된 공간에서 환기에 의한 ETS 성분 제거

  • 황건중;이문수;나도영
    • 한국연초학회지
    • /
    • 제21권1호
    • /
    • pp.102-108
    • /
    • 1999
  • This study was conducted to evaluate the ventilation to remove gases, vapor and particles of environmental tobacco smoke(ETS) in a closed room. The ventilation rate choosed were 0.445 ㎥/min, 0.528 ㎥/min, and 0.625 ㎥/min. ETS components measured were total suspended particle(TSP), ultraviolet particulate matter(UVPM), fluorescent particulate matter(FPM), solanesol, carbon dioxide($CO_2$), carbon monoxide(CO), nicotine, and 3-ethenylpyri-dine(3-EP). The concentration of ETS components measured rapidly decreased as increasing ventilation rate, but the removal efficiency by ventilation was different from each ETS compounds. The $CO_2$, and CO, gaseous components of ETS, were dominant components to be removed from the room by ventilation. The ventilation with 0.528 ㎥/min for 1 hr was enough to remove over 99% of those gaseous components. Nicotine and 3-EP needed the ventilation for 2 hrs to reduce over 95 % of those components. As the same ventilation rate, 99 % of TSP and solanesol concentration were removed from the room within 2 hrs, UVPM and FPM concentration decreased 90 %.

  • PDF

한국 ETS시장, 에너지시장 및 주식시장 간의 동태적 상관관계에 관한 연구 (A Study on the Dynamic Correlation between the Korean ETS Market, Energy Market and Stock Market)

  • 양국동;이은화
    • 무역학회지
    • /
    • 제48권4호
    • /
    • pp.189-208
    • /
    • 2023
  • 본 논문은 한국 ETS시장, 에너지시장 및 주식시장 간의 동태적 조건부 상관관계를 분석하였다. 본 논문은 2015년 2월 2일부터 2021년 12월 30일까지의 한국 탄소배출권 거래가격, WTI원유 선물가격, 코스피지수의 일별 자료를 이용하여 실증분석하였다. 우선, GARCH 모형을 사용하여 세 시장의 변동성에 대해 분석한 후, 이변량 DCC-GARCH 모형을 사용하여 세 시장 간의 동태적 조건부 상관관계를 연구하였다. 연구결과는 다음과 같다. 첫째, 한국의 ETS시장이 주식시장보다 투자 수익률과 투자 위험도가 높은 것으로 나타났다. 둘째, 한국 ETS시장의 수익률 변동성이 외부 충격의 영향을 가장 많이 받고, 시장 자체의 변동성 정보로부터 받는 영향이 가장 작은 것으로 나타났다. 셋째, 한국 ETS시장이 WTI원유 선물시장보다 주식시장과의 상관관계의 지속성이 더 강한 것으로 나타났다. 본 논문은 한국 ETS시장, 에너지시장 및 주식시장 간의 상관관계를 분석하여 한국 ETS시장의 금융화 수준이 상당히 낮은 것을 확인하였다.

음이온 발생 공기청정기에 의한 밀폐된 실내공간에서의 ETS성분 변화 (Effect of Anion Generating Air Cleaner on the Components of ETS in a Closed Room)

  • 황건중;이문수;나도영
    • 한국연초학회지
    • /
    • 제20권1호
    • /
    • pp.124-130
    • /
    • 1998
  • This study was conducted to evaluate the ability of anion generating air cleaner to remove gases, vapor and particles from closed room contaminated with environmental tobacco smoke (ETS). The measurements covered particle sizes of 13.8-542.5nm, particle concentration, surface area, volumes UVPM, FPM, solanesol, and the following gases and vapor; carbon dioxide, carbon monoxide, nicotine, and 3-ethenylpyridine. Tobacco smoke was generated and mixed in a closed room in which the airflow rates were in the range of 0.00-0.04 m/s. The anion generating air cleaner was startedl and the decay rates for the gases, vapor and particles were measured, When the use of anion generating air cleaner, solid components of ETS, such as respirable suspended particle (RSP), utraviolet particulate matter (UVPM, fluorescent particulate matter (FPM) and solanesol was sharply decreased, and vapor phase components of ETS, such as nicotines 3-ethenylpyidine were modelately decreased by time elapse. Even the use of anion generation air cleaner, the decreasing rate of carbon dioxide concentration was similar with control, and the decreasing rate of carbon monoxide was slower than that of control. Our results indicated that the use of anion generting air cleaner had an effect on reduction of solid and vapor components from ETs, but it had no effect on gaseous components of ETS.

  • PDF

서울시 일부 음식점 종업원의 간접흡연 노출량 측정 (Environmental Tobacco Smoke Exposure of Workers at Restaurants in Seoul Metropolitan City)

  • 고영림;양원호;정문호
    • 한국환경보건학회지
    • /
    • 제28권2호
    • /
    • pp.173-182
    • /
    • 2002
  • Exposure to environmental tobacco smoke(ETS) increases the risk of lung cancer and other diverse health effect for nonsmokers. Health risk assessment of nonsmokers related to ETS exposure requires large and exact data of ETS exposure to nonsmokers. This study presented the data of ETS exposure to workers at three category of restaurants(Korean restaurant, coffee shop, wine shop) in Seoul. Markers of ETS exposure measured in this study were area and personal NO$_2$, area and urine nicotine, area respiratory suspended particulate(RSP) and urine cotinine. The mean concentration of RSP and nicotine of all restaurant indoor samples was 177.8$\mu\textrm{g}$/㎥(range:75.3~317.0$\mu\textrm{g}$/㎥) and 7.8$\mu\textrm{g}$/㎥(range:0~57.3$\mu\textrm{g}$/㎥). The mean concentration of urine cotinine measured for the biomarker of ETS exposure was 77.3ng/mL(range:17.3~174.6ng/mL). In all measurements, the concentration of ETS markers at the wine shop was higher than those at other restaurants. The correlation coefficient among the ETS markers measured in the study was significant between area RSP and nicotine concentration and between area NO$_2$and nicotine concentration.

한국의 탄소배출권 거래제 시행 1년 후 현황과 개선방안 - EU 배출권 거래제와 비교를 통하여 - (Status of Korea ETS and Strategies to improve in One Year After Launching - Through Comparing with EU ETS -)

  • 채종오;박선경
    • 한국기후변화학회지
    • /
    • 제7권1호
    • /
    • pp.41-48
    • /
    • 2016
  • Korea has introduced Korea Emissions Trading Scheme (Korea ETS) since 2015. However, not many companies voluntarily participate in the emissions trading. The goal of this paper is to provide the way to improve the Korea ETS. This study compares the Korea ETS with EU Emissions Trading System, which has been practiced for a decade, and suggests three strategies to activate the Korea Emissions Trading Scheme. The first thing is to encourage more companies to participate in the emissions trading since the number of companies in the emissions trading in Korea is quite limited compared with that of EU. The second thing is to activate the trading of Korean Credit Unit in order to stimulate various emission reduction mechanisms. Currently, the most of the trading in the emissions market is through the Korean Allowance Unit. The third thing is to establish concrete measures to continuously improve the Korea ETS. A comprehensive evaluation of the Korea ETS is needed along with the ongoing convergence with the associated comments. The improvement of Korea ETS would be one of the most efficient ways to compete the climate change, and would also play a role to raise the status of Korea.

배출권거래제의 국제적 적용이 한국산업과 무역에 미치는 효과 (The effect of international linkage of emissions trading markets on Korean industries)

  • 오경수
    • 무역학회지
    • /
    • 제47권1호
    • /
    • pp.115-130
    • /
    • 2022
  • In this study, I focus on analyzing how the effects of implementing ETS are different depending on whether Korean ETS linking with carbon markets in other countries. The global computable general equilibrium (CGE) model built in this study analyzes the chages in the production and trade of industrial sectors according to the international linkage of ETS compared to the reference scenario of emissions reduction targets and implementation of ETS. From the analysis of internatioanl linkage of carbon markets scenarios, Annex B countries-South Korea carbon market linkage with individual ETS in China worse the economic outcomes in South Korea the most. This means South Korea lose the international competitiveness compared to China in this scenario. On the other hand, Annex B-China carbon market linkage with Korean individual ETS implementation reduce the decreases in production and trading. The most effective way is to join a global emissions trading market with China. The results are consistent in most industries of South Korea. These results are caused by that the supply of emission allowance is increased and the price of emissions allowances is dropped by China's participation to the carbon market, which can be understood to reduce the carbon reduction cost for industrial sectors. In addition, it can be also concluded that the determinant of the negative impact of ETS on changes in production and trade is more sensitive to the price of emissions allowances than to the characteristics of production and trade structure.

실내사무환경에서의 환경성담배연기(ETS)중 일부 휘발성유기화합물(VOC)에 관한 연구 (A Study on Volatile Organic Compounds(VOC) in Environmental Tobacco Smoke(ETS) at Indoor Office Environments)

  • 하권철
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.87-98
    • /
    • 2001
  • There has been increased interest in the health effects of the Environmental Tobacco Smoke(ETS) as a confirmed human carcinogen. It has been known to be extremely difficult to make an accurate assessment of exposure to ETS since it is consisted of a variety of components and there are a number of labile chemicals. Therefore, it is necessary to obtain, to interpretate and to provide the data of quantitative exposure assessment to ETS in the field of environmental health. The purpose of this research is to evaluate the concentration of ETS using VOC in indoor office environments. The correlations and concentrations of benzene, RSP, 3-EP, nicotine that are indicators for ETS were investigate with smoking density, air change per hour(ventilation rate). Air samples were taken in smoking room(7 sites), smoking allowed office (3 sites), corridor outside smoking room(7 sites), non-smoking office (9 sites). The concentrations of benzene showed significant difference according to category of indoor office environments. The geometric mean concentration of benzene were 23.56 ${\mu}{\textrm}{m}$/㎥(range 4.80~192.90 ${\mu}{\textrm}{m}$/㎥) in smoking rooms. 6.16 ${\mu}{\textrm}{m}$/㎥ in smoking allowed offices, 1.32 ${\mu}{\textrm}{m}$/㎥ in the non-smoking offices respectively. The ratios of the concentration of benzene between outdoor air and smoking room, smoking allowed office, and non-smoking indicators concentrations, SD, and SI were 0.82(benzene and nicotine). 0.76(benzene and RSP), 0.60(benzene and SD), 0.76(benzene and SI). It is proposed that benzene is a good indicator for ETS.

  • PDF

식당 종업원의 환경 담배 연기(ETS)의 노출과 머리카락 중 생체지표 연구 (The Study to ETS Exposure and Their Biomarkers in Hair of Restaurant Workers)

  • 조성준
    • Environmental Analysis Health and Toxicology
    • /
    • 제19권2호
    • /
    • pp.169-176
    • /
    • 2004
  • ETS (environmental tobacco smoke) is composed of exhaled mainstream smoke (MS) from the smoker, sidestream smoke (SS) emitted from the smoldering tobacco between puffs and contaminants that diffuse through the cigarette paper and mouth between puffs. These emissions contain both vapor phase and particulate contaminants. ETS is a complex mix of over 4,000 compounds. This mix contains many known or suspected human carcinogens and other toxic agents. More of these toxic compounds are found in SS than in MS. Workplace exposure to ETS can result in significant smoke intake, and passive smoke exposure may be related to impair respiratory function and an increase risk of lung cancer in nonsmokers. For nonsmokers sharing a work environment with cigarette smokers, the workplace must be considered hazardous independently of any specific industrial toxic exposure. The risk is particularly important when a high percentage of the workers smoke or where smokers and nonsmokers work in poorly ventilated areas. Nicotine is converted in the body to cotinine; cotinine therefore can be used as an indirect measure of a person's recent exposure to tobacco smoke. Levels of nicotine in hair and levels of cotinine in body fluids (saliva and urine) have been shown to increase with increasing environmental nicotine levels and with self-reported ETS exposure. The measurement of nicotine or cotinine in hair may be more appropriate for longer-term exposure to tobacco. The purpose of this study is to comparing airborne nicotine levels and hair cotinine level in restaurant workers. Concentration of airborne nicotine and hair nicotine (and cotinine) is closely related to exposed frequency of sidestream smoke in the workplace. Nicotine in hair is a better predictor of airborne nicotine than hair cotinine. Hair nicotine can be a useful tool to assess ETS exposure interventions. It may have limiting levels of ETS exposure by placing regulatory restrictions on smoking in workplaces and in public spaces.

미숙아의 기관지흡인 전 흉곽진동 간호중재가 산소포화도, 심박동수와 기도분비물의 양에 미치는 영향 (The Effects of Chest Vibration Prior to Endotracheal Suctioning on Oxygen Saturation, Heart Rate and Lung Secretions in Premature Infants)

  • 안영미
    • Child Health Nursing Research
    • /
    • 제4권2호
    • /
    • pp.245-254
    • /
    • 1998
  • Prematurity is the main cause for respiratory disorders in neonates. The goal in respiratory management is to maintain respiration with adequate oxygenation. Chest vibration(CV) prior to on dotracheal suctioning(ETS) has been arbitrarily applied to ventilated premature infants without the scientific evaluation of its safety and efficacy. A repeated measure within subjects experimental study was conducted to investigate the effects of CV prior to 875 on oxygenation and lung secretions in twenty-one ventilated premature infants. The independent variable was the type of research protocol, the control type (275 without C.V) and t he intervention(ETS with CV). The dependent variables were oxygen saturation(SpO₂), heart rate (HR), measured by pulse oximeter, and the amount of lung secretions measured in gram. The results showed there was no difference in SpO₂ responses regardless CV employed before ETS. But there was a significant difference in HR responses between the control and the intervention, even without clinical significance. There was a significant difference in the amount of lung secretions retrieved during ETS with CV, compared to ETS without CV. This study suggested the safety of CV by demonstrating no clinically significant changes in SpO₂ and HR in premature infants. The efficacy of CV could be supported by the increases in the amount of sputum during ETS with CV compared to ETS without CV in premature infants.

  • PDF